Scope
GB/T 15092.101-2020 (Switches for appliances - Part 1-1: Requirements for mechanical switches) is available as an English-translated PDF.
GB/T 15092.101-2020 — Chapter 1 of GB/T 15092:1-2020 applies: Add at the end of Chapter 1 of GB/T 15092:1-2020: This part of GB/T 15092 applies to mechanical switching appliances and should be used in conjunction with GB/T 15092:1-2020: Note: Additional requirements for special switches can refer to Part 2 of GB/T 15092:
Document preview — GB/T 15092.101-2020
National Standard of the People's Republic of China
- ICS
- 29.120.40
- Classification
- K 64
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms and definitions1
- 4 General requirements1
- 5 General precautions for the test1
- 6 Rating3
- 7 Category3
- 8 Signs and documents3
- 9 Protection against electric shock3
- 10 Grounding device3
- 11 Terminals and ends3
- 12 Structure3
- 13 Organization3
- 14 Anti-solid foreign matter, waterproof and moisture-proof3
- 15 Insulation resistance and dielectric strength3
- 16 Fever3
- 17 Durability4
- 18 Mechanical strength9
- 19 Screws, current carriers and couplings9
- 20 Electrical clearance, creepage distance, solid insulation and coating of hard printed circuit board components9
- 21 Fire hazard9
- 22 Rust prevention9
- 23 Abnormal operation and fault conditions of the switch9
- 24 Switching components10
- 25 Electromagnetic compatibility (EMC) requirements10
- Reference11
- Table 101 Test sample1
- Table 102 AC electrical durability test load4
- Table 103 DC electrical endurance test load5
- Table 104 Switch operating conditions7
Foreword
GB/T 15092 "Appliance Switch" is divided into the following parts:
---Part 1: General requirements;
---Part 1-1: Mechanical switch requirements;
---Part 1-2: Requirements for electronic switches;
---Part 2: Special requirements;
* Special requirements for soft cord switches;
* Special requirements for conversion selector;
* Special requirements for independent installation switches;
* Special requirements for hand-held and portable power tools and garden machinery switches:
This part is Part 1-1 of GB/T 15092:
This section was drafted in accordance with the rules given in GB/T 1:1-2009:
This section uses the redrafting method to modify and adopt IEC 61058-1-1:2016 "Appliance Switch Part 1-1: Mechanical Switch Requirements":
The technical differences between this part and IEC 61058-1-1:2016 and the reasons are as follows:
---IEC 61058-1-1:2016's 14:3 stipulates: "The humidity treatment is carried out in a humid chamber, and the relative humidity of the air in the chamber is 91%~
Between 95%: In all places where the sample is placed, the air temperature is maintained at any suitable temperature (t) between 20°C and 30°C",
Considering that some areas of our country have a humid tropical climate, and all electrical and electronic products in our country use (40+/-2) degrees C for moisture resistance test,
Therefore, this part stipulates: "The humidity treatment is carried out in a humid chamber, and the relative humidity of the air in the chamber is between 91% and 95%:
In all places where the sample is placed, the air temperature should be maintained at any suitable temperature (t) between 30°C and 40°C: This requirement is consistent with
GB/T 2423:4-2008 adopts the same severity level:
---IEC 61058-1-1:2016 17:5:6 stipulates: "When required in Chapter 13, use 3 samples of different test groups for
TC10 test, instead of the sample part in the test sequence of Table 101, pass 17:6:1 (TE1) and 17:6:2 (TE2) to test", consider
Considering that 17:6:2 (TE2) is the thermal conformity assessment, which is for the complete sequence test of Chapter 14, Chapter 15, Chapter 16, and Chapter 17:
After the assessment, the TC10 test is an institutional assessment conducted using 3 samples from different test groups, and passed 17:6:1
(TE1) and 17:6:3 (TE3) are more reasonable to test, that is, functional qualification and insulation qualification are used to evaluate the test results: So the headquarters
Sub-regulations: "When required in Chapter 13, use 3 samples from different test groups for the TC10 test instead of the table 101 test:
The sample part of the test sequence is tested through 17:6:1 (TE1) and 17:6:3 (TE3)":
This section has made the following editorial changes:
---Added references:
This part was proposed by China Electrical Equipment Industry Association:
This part is under the jurisdiction of the National Electrical Accessories Standardization Technical Committee (SAC/TC67):
Drafting organizations of this section: Shanghai Electric Tool Research Institute (Group) Co:, Ltd:, Zhejiang Zhongxun Electronics Co:, Ltd:, Zhangjiagang Huajie Electronics
Co:, Ltd:, Zhejiang Jiaben Electronics Co:, Ltd:, Changzhou Yunjie Electric Co:, Ltd:, Yueqing Huiyang Electromechanical Co:, Ltd:, Zhejiang Guanbao Electronics Co:, Ltd:
Co:, Ltd:, Fa-German Electric Co:, Ltd:, Zhejiang Changlong Electric Co:, Ltd:, Southeast Electronics Co:, Ltd:, Zhongshan Yonglian Electrical Products Co:, Ltd:
The company, Zhongren Shangdong (Shanghai) Testing Technology Co:, Ltd:, Weikai Testing Technology Co:, Ltd:, Zhejiang Heling Electric Co:, Ltd:
1 Scope
Chapter 1 of GB/T 15092:1-2020 applies:
Add at the end of Chapter 1 of GB/T 15092:1-2020:
This part of GB/T 15092 applies to mechanical switching appliances and should be used in conjunction with GB/T 15092:1-2020:
Note: Additional requirements for special switches can refer to Part 2 of GB/T 15092:
2 Normative references
The following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article
Pieces: For undated references, the latest version (including all amendments) applies to this document:
Chapter 2 of GB/T 15092:1-2020 applies:
3 Terms and definitions
Chapter 3 of GB/T 15092:1-2020 applies:
4 General requirements
Chapter 4 of GB/T 15092:1-2020 applies:
5 General considerations for the test
After adding the following requirements, GB/T 15092:1-2020 Chapter 5 applies:
Added at the end of 5:4:
Table 101 provides precautions for the following aspects:
---The minimum number of samples required for each test;
--- When adding appropriate tests, the minimum number of total samples required for each evaluation;
---Additional samples required due to increased electrical ratings, specific structures, or damage or rupture during the test:
Table 101 Test samples
Article number entry minimum number of each test sample a Remarks
5 General precautions for the test-iib
6 Rating
7 categories
8 Signs and documents
1 c
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 15092
How to Buy GB/T 15092.101-2020
- 1Add to cart. Click the "Buy GB/T 15092.101-2020" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 15092.102-2020 — Switches for appliances - Part 1-2: Requirements for electronic switches
GB/T 15092.2-2023 — Switches for appliances - Part 2-1: Particular requirements for cord switches
GB/T 15092.3-2023 — Switches for appliances - Part 2-5: Particular requirements for change-over selectors
Secure payment via Stripe
Payments accepted
GB/T 15092.101-2020
$215.00