GB/T 15076.6-2020Methods for chemical analysis of tantalum and niobium—Part 6:Determination of silicon content—Inductively coupled plasma atomic emission spectrometry (English PDF)
钽铌化学分析方法 第6部分:硅量的测定 电感耦合等离子体原子发射光谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 15076.6-2020 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
March 6, 2020
Implementation date
February 1, 2021
Scope
GB/T 15076.6-2020 is the English-translated version of 钽铌化学分析方法 第6部分:硅量的测定 电感耦合等离子体原子发射光谱法.
GB/T 15076.6-2020 is the part of the Chinese series on the chemical analysis of tantalum and niobium that determines the silicon content by inductively coupled plasma atomic emission spectrometry.
It gives the principle, the reagents and materials, the apparatus, the test procedure, the processing of the data, the precision and the test report. It applies to tantalum, niobium and their hydroxides, oxides, carbides and to potassium fluorotantalate, for silicon contents from 0.0005 % to 0.50 %.
Tantalum and niobium producers and analytical laboratories use it. Issued on 6 March 2020, it has applied since 1 February 2021, replacing GB/T 15076.6-1994.
Found what you need?
Document preview — GB/T 15076.6-2020
National Standard of the People's Republic of China
- ICS
- 77.120.99
- Classification
- H 14
- Replacing
- GB/T 15076.6-1994
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Principle
- 3 Reagents or materials
- 4 Equipment
- 5 Samples
- 6 Test procedure
- 7 Test data processing
- 8 Precision
- 9 Test report
Foreword
GB/T 15076 "Methods for Chemical Analysis of Tantalum and Niobium" is divided into 16 parts.
---Part 1: Determination of tantalum content in niobium by inductively coupled plasma atomic emission spectrometry;
---Part 2: Determination of the amount of niobium in tantalum inductively coupled plasma atomic emission spectrometry and chromatography gravimetric method;
---Part 3: Determination of copper content by flame atomic absorption spectrometry;
---Part 4: Determination of iron content 1,10-phenanthroline spectrophotometry;
---Part 5: Determination of the amount of molybdenum and tungsten by inductively coupled plasma atomic emission spectrometry;
---Part 6: Determination of silicon content by inductively coupled plasma atomic emission spectrometry;
---Part 7: Determination of phosphorus content in niobium 4-methyl-pentanone-[2] extraction separation phosphomolybdenum blue spectrophotometry and inductively coupled plasma Bulk atomic emission spectroscopy;
---Part 8: Determination of carbon and sulfur content by high-frequency combustion infrared absorption method;
---Part 9: Determination of the amount of iron, chromium, nickel, manganese, titanium, aluminum, copper, tin, lead and zirconium in tantalum by DC arc atomic emission spectrometry;
---Part 10: Determination of the content of iron, nickel, chromium, titanium, zirconium, aluminum and manganese in niobium by DC arc atomic emission spectrometry;
---Part 11: Determination of arsenic, antimony, lead, tin and bismuth in niobium by DC arc atomic emission spectrometry;
---Part 12: Determination of Phosphorus in Tantalum by Ethyl Acetate Extraction and Separation of Phosphomolybdenum Blue Spectrophotometry;
---Part 13: Determination of nitrogen content inert gas fusion thermal conductivity method;
---Part 14: Determination of oxygen content inert gas melting infrared absorption method;
---Part 15: Determination of hydrogen content inert gas fusion thermal conductivity method;
---Part 16: Determination of sodium and potassium content by flame atomic absorption spectrometry.
This part is Part 6 of GB/T 15076.
This section was drafted in accordance with the rules given in GB/T 1.1-2009.
This part replaces GB/T 15076.6-1994 "Methods for chemical analysis of tantalum and niobium-Determination of silicon content in tantalum". This part is consistent with GB/T 15076.6- Compared with.1994, the main technical changes except for editorial changes are as follows.
---The measurement method was changed from "spectrophotometry" to "inductively coupled plasma atomic emission spectrometry";
---Expanded the measurement range, the measurement range was changed from "0.0005%~0.070%" to "0.0005%~0.50%" (see Chapter 1, Chapter 1 and Chapter 9 of the 1994 edition);
---The reference standard is deleted (see Chapter 2 of the 1994 edition);
---Add sample clause (see Chapter 5);
--- Added precision clause (see Chapter 8);
---Added the test report clause (see Chapter 9).
1 Scope
This part of GB/T 15076 specifies the determination of silicon content in tantalum and niobium by inductively coupled plasma atomic emission spectrometry.
This section applies to the determination of silicon content in tantalum, niobium and their hydroxides, oxides, carbides and potassium fluorotantalate. Measuring range. 0.0005%~0.50%.
2 Principle
The sample is dissolved in nitric acid and hydrofluoric acid, in a dilute acid medium, using argon plasma as the ionization source, and direct inductively coupled plasma Atomic emission spectrometry.
3 Reagents or materials
Unless otherwise stated, only reagents confirmed to be MOS grade and laboratory grade 2 water are used in the analysis.
3.1 Nitric acid (rho=1.42g/mL).
3.2 Hydrofluoric acid (rho=1.14g/mL).
3.3 Metal tantalum (wTa>=99.99%, wSi<=0.0001%).
3.4 Niobium metal (wNb>=99.99%, wSi<=0.0001%).
3.5 Silicon standard storage solution. Weigh 2.1394g silica (wSiO2>=99.99%) into a platinum crucible, add 10g sodium carbonate-potassium carbonate Mix the flux, mix well, melt on the blowtorch until it is clear, then burn for 10 minutes. After cooling, immerse with hot water, heat until the solution is clear, and move after cooling Put it into a 1000mL volumetric flask, dilute to the mark with water, and mix well. 1mL of this solution contains 1mg of silicon. Store in a polyethylene bottle.
3.6 Silicon standard solution. Pipette 10.00mL silicon standard stock solution (3.5) in a 100mL volumetric flask, dilute to the mark with water, and mix. 1mL of this solution contains 100µg of silicon. Store in a polyethylene bottle.
3.7 Argon (volume fraction not less than 99.99%).
4 Equipment
4.1 Inductively coupled plasma atomic emission spectrometer, equipped with hydrofluoric acid resistant sampling system, resolution < 0.006nm (200nm).
4.2 The recommended silicon analysis line is 251.612nm.
5 Samples
5.1 The particle size of tantalum powder is less than 700µm; the particle size of niobium powder is less than 180µm; the particle size of tantalum-niobium carbide is less than 150µm.
5.2 Tantalum powder should be dried in vacuum at 80°C~150°C for 4h in advance, cooled to room temperature, and vacuum packaged in a composite aluminum foil bag; Substances, oxides and potassium fluorotantalate should be pre-baked at 105°C~110°C for 2h, and placed in a desiccator to cool to room temperature for later use.
5.3 From the top 10cm of the niobium ingot to any part of the middle, use a planer to remove the skin and sample the shavings. The size of the shavings should be uniform, and And the particles should be as small as possible.
6 Test procedure
6.1 Sample
Weigh the sample according to Table 1, accurate to 0.0001g.
6.2 Parallel test
Do two tests in parallel and take the average value.
6.3 Blank test
Weigh the metal tantalum (3.3) or metal niobium (3.4) equivalent to the sample, and do a blank test with the sample.
6.4 Preparation of analysis test solution
6.4.1 Place the tantalum-niobium sample (6.1) in a 100mL polyethylene/PTFE beaker and moisten it with a little water.
6.4.2 Slowly add 2mL of nitric acid (3.1), and 4mL of hydrofluoric acid (3.2) dropwise. After the violent reaction stops, place in a water bath not higher than 60°C Heat to complete dissolution, remove and cool, add 2mL nitric acid (3.1). Transfer the solution into a 100mL polyethylene volumetric flask and dilute with water to Scale and mix well. When the oxide is not easy to dissolve to clarification by this method, a hot-pressure digestion device can be used to dissolve the sample.
6.5 Drawing of working curve
6.5.1 Working curve I
According to Table 1, weigh 6 parts of metal tantalum (3.3) or metal niobium (3.4) equivalent to the sample, and place them in 6 100mL polyethylene plastic bottles.
Add 0mL, 0.050mL, 0.20mL, 0.50mL, 2.00mL, 5.00mL silicon standard solution (3.6) respectively, the following steps are according to 6.4.2 operating.
6.5.2 Working curve II
According to Table 1, weigh 6 parts of metal tantalum (3.3) or metal niobium (3.4) equivalent to the sample, and place them in 6 100mL polyethylene plastic bottles.
Add 0mL, 0.50mL, 1.00mL, 2.00mL, 5.00mL, 10.00mL silicon standard solution (3.6) respectively, the following steps follow 6.4.2 operating.
6.6 Determination
After the instrument is optimized, according to the recommended analysis line, measure the emitted light intensity of the measured element in the standard series of the working curve drawn from low to high.
Taking the mass concentration as the abscissa and the intensity of the emitted light from the analysis line as the ordinate, the computer automatically draws the working curve. When the linear relationship of the working curve When it reaches above 0.999, measure the emitted light intensity of the measured element in the sample blank solution (6.3) and sample solution (6.4.2), and the computer will automatically Calculate the mass concentration of the measured element from the working curve.
7 Test data processing
The silicon content is calculated as the mass fraction of silicon wSi, calculated according to formula (1).
When wSi< 0.010%, the result obtained is kept to four decimal places; when wSi>=0.010%, the result obtained keeps three significant digits.
8 Precision
8.1 Repeatability
The measured values of two independent test results obtained under repeatability conditions are within the average range given in Table 2. These two test results The absolute difference does not exceed the repeatability limit (r), and the case of exceeding the repeatability limit (r) does not exceed 5%. Repeatability limit (r) adopts the line according to the data in Table 2 Obtained by sexual interpolation or extension method.
8.2 Reproducibility
The measured values of two independent test results obtained under reproducibility conditions are within the range of the average value given in Table 3.
The absolute difference does not exceed the reproducibility limit (R), and does not exceed 5% in the case of exceeding the reproducibility limit (R). Reproducibility limit (R) is adopted according to the data in Table 3 Obtained by linear interpolation or extension method.
9 Test report
The test report should include the following.
---Test object;
---This part number;
---result;
--- Anomalies observed;
---Test date.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
Editions of GB/T 15076.6
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 15076.6-2020 | Methods for chemical analysis of tantalum and niobium—Part 6:Determination of silicon content—Inductively coupled plasma atomic emission spectrometry | current edition | Current |
| GB/T 15076.6-1994 | Methods for chemical analysis of tantalum and niobium—Part 6:Determination of silicon content—Inductively coupled plasma atomic emission spectrometry | previous edition | Superseded |
This page sells the current edition, GB/T 15076.6-2020. Earlier editions are listed for reference only.
How to Download GB/T 15076.6-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 15076.7-2020 — Methods for chemical analysis of tantalum and niobium—Part 7:Determination of phospherus content in niobium—4-Formyloxy-pentyl ketone-2 extraction separation phosphomolybdate blue spectrophotometry and inductively coupled plasma atomic emission spectrometry
GB/T 15076.5-1994 — Methods for chemical analysis of tantalum and niobium. Determination of molybdenum and tungsten contents
GB/T 15076.7-1994 — Methods for chemical analysis of tantalum and niobium. Determination of phospherus content in niobium
Secure payment via Stripe
Payments accepted
GB/T 15076.6-2020