Valid

GB/T 15076.3-2019Methods for chemical analysis of tantalum and niobium—Part 3: Determination of copper content—Flame atomic absorption spectrometry (English PDF)

钽铌化学分析方法 第3部分: 铜量的测定 火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 15076.3-2019 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 4, 2019

Implementation date

January 1, 2020

Scope

GB/T 15076.3-2019 is the English-translated version of 钽铌化学分析方法 第3部分: 铜量的测定 火焰原子吸收光谱法.

GB/T 15076.3-2019 is the Chinese national method for measuring copper in tantalum, niobium and their hydroxides by flame atomic absorption spectrometry, over the range 0.000 2% to 0.060%.

The sample is dissolved in hydrofluoric and nitric acid, fumed with sulfuric acid, boiled so that the tantalum and niobium hydrolyse and dry-filtered to remove the matrix; the absorbance of the filtrate is read at 324.7 nm.

The Part lists the reagents and the copper stock and working solutions, the characteristic concentration, precision and working-curve linearity the spectrometer has to reach, how powders, hydroxides and ingot samples are taken, the test steps, the processing of data, the precision and the test report.

It is Part 3 of GB/T 15076, replaces GB/T 15076.3-1994, was issued on 4 June 2019 and has applied since 1 January 2020.

Found what you need?

Document preview — GB/T 15076.3-2019

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 14
Replacing
GB/T 15076.3-1994

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope5
  • 2 Principle5
  • 3 Reagents5
  • 4 Instruments and apparatuses6
  • 5 Sample6
  • 6 Test steps6
  • 7 Test data processing8
  • 8 Precision8
  • 9 Test report9

Foreword

GB/T 15076, Methods for chemical analysis of tantalum and niobium, is divided into 16 parts:

-- Part 1: Determination of tantalum content in niobium. Inductively coupled plasma atomic emission spectrometry;

-- Part 2: Determination of tantalum content in niobium;

-- Part 3: Determination of copper content. Flame atomic absorption spectrometry;

-- Part 4: Determination of iron content;

-- Part 5: Determination of molybdenum and tungsten contents. Inductively coupled plasma atomic emission spectrometry;

-- Part 6: Determination of silicon content in tantalum;

-- Part 7: Determination of phosphorus content in niobium;

-- Part 8: Determination of carbon and sulphur contents

-- Part 9: Determination of iron, chromium, nickel, manganese, titanium, aluminum, copper, tin, lead and zirconium contents in tantalum;

-- Part 10: Determination of iron, nickel, chromium, titanium, zirconium, aluminum and manganese contents in niobium;

-- Part 11: Determination of arsenic, antimony, lead, tin and bismuth contents in niobium;

-- Part 12: Determination of phosphorus content in tantalum;

-- Part 13: Determination of nitrogen content. Inert gas fusion thermal conductivity method;

-- Part 14: Determination of oxygen content;

-- Part 15: Determination of hydrogen content;

-- Part 16: Determination of sodium and potassium contents;

This Part is the 3rd part of GB/T 15076.

This Part was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This Part of GB/T 15076 specifies the methods for determining the copper content in tantalum, niobium and their hydroxides.

This Part applies to the determination of copper content in tantalum, niobium and their hydroxides. Determination range: 0.000 2% ~ 0.060%.

2 Principle

Use hydrofluoric acid and nitric acid to dissolve the sample. After the sulfuric acid smokes, add an appropriate amount of nitric acid; boil to sufficiently hydrolyze tantalum and niobium; dry-filter to remove the tantalum and niobium matrix. Place the filtrate at the wavelength of 324.7 nm of an atomic absorption spectrometer to measure its absorbance; calculate the copper content.

3 Reagents

Unless otherwise specified, all the used reagents are guaranteed reagents and laboratory grade-2 water.

3.1 Hydrofluoric acid (rho = 1.14 g/mL).

3.2 Nitric acid (rho = 1.42 g/mL).

3.3 Sulfuric acid (1+1).

3.4 Copper standard stock solution: weigh 1.000 0 g of metallic copper (wCu >= 99.99%) in a 300 mL beaker; add 40 mL of nitric acid (1+1) to dissolve at a lower temperature. Boil; drive off the nitrogen oxides; take down for cooling; transfer to a 1 000 mL volumetric flask; add 80 mL of nitric acid (3.2); use water to dilute to the mark; mix well. 1 mL of this solution contains 1.0 mg of copper.

3.5 Copper standard solution: pipette 10.00 mL of copper standard stock solution (3.4) into a 1 000 mL volumetric flask; add 50 mL of nitric acid (3.2); use water to dilute to the mark; mix well. 1 mL of this solution contains 10 µg of copper.

4 Instruments and apparatuses

Atomic absorption spectrometer that is equipped with copper hollow cathode lamp.

Under the best working conditions of the instrument, anything that can achieve the following indicators can be used:

-- Characteristic concentration: in the solution that is consistent with the matrix of the measuring solution, the characteristic concentration of copper shall be no more than 0.05 µg/mL;

-- Precision: use the standard solution of the highest concentration to measure the absorbance for 10 times; its standard deviation shall not exceed 1.0% of the average absorbance. Use the standard solution of the lowest concentration (standard solution whose concentration is not "zero") to measure the absorbance for 10 times; its standard deviation shall not exceed 0.6% of the average absorbance of the standard solution of the highest concentration;

-- Linearity of working curve: divide the standard curve into five segments according to the concentration; the ratio OF the absorbance difference of the highest segment TO the absorbance difference of the lowest segment shall not be less than 0.70.

5 Sample

5.1 The particle size of tantalum and niobium powder shall be less than 180 µm.

5.2 The hydroxides of tantalum and niobium shall be preheated at 105°C ~ 110°C for 2 h; place in a desiccator to cool to room temperature.

5.3 From 10 cm to the top of the ingot to any part in the middle, use the planer to remove the epidermis and shave the sample; the clastic particles shall be uniform in size and the particles shall be as thin as possible.

6 Test steps

6.1 Samples

Weigh the samples according to Table 1, accurate to 0.000 1 g. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

Editions of GB/T 15076.3

EditionTitleRevisionStatus
GB/T 15076.3-2019Methods for chemical analysis of tantalum and niobium—Part 3: Determination of copper content—Flame atomic absorption spectrometrycurrent editionCurrent
GB/T 15076.3-1994Methods for chemical analysis of tantalum and niobium—Part 3: Determination of copper content—Flame atomic absorption spectrometryprevious editionSuperseded

This page sells the current edition, GB/T 15076.3-2019. Earlier editions are listed for reference only.

How to Download GB/T 15076.3-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 15076.3-2019

$75.00