GB/T 12944.1-1991High-voltage ceramic wall bushings (English PDF)
This is a limited preview
Buy now to download the full PDF (21 pages)
Need quotation for your management?
Get a formal quotation for GB/T 12944.1-1991 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
July 29, 2011
Implementation date
December 1, 2011
Scope
GB/T 12944.1-1991 (High-voltage ceramic wall bushings) is available as an English-translated PDF.
GB/T 12944.1-1991 — This standard specifies the high-voltage ceramic wall bushings - the technical requirements, testing requirements, structure type, size and characteristics.
This standard applies to nominal voltage 6kV ~ 35kV, frequency 15Hz ~ 60Hz three-phase AC system in the power station and substation power distribution Within the means used indoor, outdoor - indoor wall bushings (hereinafter referred to as the casing).
Sleeve for horizontal installation, the indoor casing can be installed vertically. This standard does not apply under conditions sufficient to reduce the performance of the sleeve and the sleeve at the casing surface condensation client situations.
Found what you need?
Document preview — GB/T 12944.1-1991
National Standard of the People's Republic of China
- ICS
- 29.080.10
- Classification
- K 48
- Replacing
- GB/T 12944.2-1991
Issued by: Standardization Administration of China
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Operating conditions, ordering information and identification
- 5 Structure type
- 5.1 The basic structure of the sleeve type
- 5.2 Sleeve type
- 6 2 Technical Requirements
- 6.1 General requirements
- 6.2 Dimensions and characteristics
- 6.3 Size tolerance
- 6.4 Visible corona voltage
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard replaces GB/T 12944.2-1991 "high voltage ceramic wall bushings - Dimensions and characteristics", and GB/T 12944.2-1991 phase Ratio, in addition to editorial changes outside the main technical changes are as follows.
--- Increased "operating conditions, ordering information and identification" section (see Chapter 4);
--- Increased "technical requirements" chapter, in addition to the technical conditions GB/T 4109-2008 regulations, the increase in the visible corona voltages and tolerances and other requirements (see Chapter 6);
--- Added "Test Requirements" chapter, in addition to the test requirements GB/T 4109-2008 the provisions in the type test increased visibility electricity Halo voltage test requirements, and provides a number of samples for type test (see Chapter 7);
--- Press highest voltage for equipment GB 311.1 is revised draft of the provisions of the revised standard rated voltage value (see Tables 2 and 3);
--- According to a unified concept creepage distance (USCD) dressing each grade bushing creepage distance, and adds some creepage distance rating and rated current of the product (see Tables 2 and 3);
--- Cancel the original structure 8 (see GB/T 12944.2-1991 Figure 8);
--- Increased when the maximum ambient temperature is above or below 40 °C sleeve use provisions (see Appendix A).
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the National Standardization Technical Committee Insulators (SAC/TC80) centralized.
This standard was drafted. Suzhou Electric Porcelain Co., Ltd., Xi'an High Voltage Apparatus Research Institute Co., Ltd., the National Insulator arrester Quality Supervision, Inspection Center, State Grid Electric Power Research Institute, Nanjing Electric (Group) Co., Ltd. Tangshan high-voltage porcelain, China Electric Power Division Graduate School.
Drafters of this standard. Miss Chau, Yao Junrui, Daiyu Jun, Zhao Hui, Wei Peng, Zhang Rui, Gurui Yun, Yang Ming, TRANSACTIONS OF THE.
This standard replaces the standards previously issued as follows.
--- GB/T 12944.2-1991;
--- GB 1247-1977, GB 770-1988, GB 771-1988.
High voltage ceramic wall bushings
1 Scope
This standard specifies the high-voltage ceramic wall bushings - the technical requirements, testing requirements, structure type, size and characteristics.
This standard applies to nominal voltage 6kV ~ 35kV, frequency 15Hz ~ 60Hz three-phase AC system in the power station and substation power distribution Within the means used indoor, outdoor - indoor wall bushings (hereinafter referred to as the casing).
Sleeve for horizontal installation, the indoor casing can be installed vertically.
This standard does not apply under conditions sufficient to reduce the performance of the sleeve and the sleeve at the casing surface condensation client situations.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 197-2003 common thread tolerance GB 311.1 insulation with high-voltage power transmission equipment GB/T 1804-2000 General tolerances Tolerances for linear and angular dimensions without individual tolerance GB/T 2900.8-2009 Electrical insulators term GB/T 4109-2008 AC voltage greater than 1000V insulating sleeve GB/T 5273-1985 transformers, high-voltage electrical terminals and casing GB/T 5585.1-2005 electrician with copper, aluminum and its alloy bus - Part 1. Copper and copper alloy bus GB/T 5585.2-2005 electrician with copper, aluminum and its alloy bus - Part 2. Aluminium and aluminum busbars GB/T 23752-2009 rated voltages greater than 1000V electrical equipment with pressurized and non-pressurized hollow porcelain and glass insulators JB/T 4307-2004 insulators fitted with rubber cement glue
3 Terms and Definitions
Terms and definitions GB/T 2900.8-2009 and GB/T 4109-2008 defined apply to this document.
4 Operating conditions, ordering information and identification
Operating conditions and ordering information should be consistent with the provisions of GB/T 4109-2008 in Chapter 5 and 6.1, the logo should comply with 10.3.
The ambient temperature exceeds or falls below 40 °C when the cannula used in Appendix A.
5 Structure type
5.1 The basic structure of the sleeve type the basic structure of the sleeve type shown in Figure 1 to 9.
5.2 Sleeve models
Model a) with conductor ceramic wall bushings are shown below.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 197-2003General purpose metric screw threads -- Tolerances
- GB 311.1Insulation co-ordination -- Part 1: Definitions, principles and rules
- GB/T 1804-2000General tolerances - Tolerances for linear and angular dimensions without individual tolerance indications
- GB/T 4109-2008Insulated bushings for alternating voltages above 1 000 V
- GB/T 5273-1985Dimensional standardisation of terminals for high-voltage apparatus
- GB/T 5585.1-2005Copper or aluminium and its alloy bus bars for electrical purposes—Part 1: Copper and copper alloy bus bars
GB/T 2900.8-2009 · GB/T 23752-2009
How to Download GB/T 12944.1-1991
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 311.1-2012 — Insulation co-ordination -- Part 1: Definitions, principles and rules
GB/T 1804-2000 — General tolerances - Tolerances for linear and angular dimensions without individual tolerance indications
JB/T 4307-2004 — Cement mortar for assembling insulators
Secure payment via Stripe
Payments accepted
GB/T 12944.1-1991
$554.00