GB 5959.5-2014 is the English-translated version of 电热装置的安全 第5部分:对等离子体装置的特殊要求.

GB 5959.5-2014 is the Chinese national standard on safety in electroheat installations-part 5: particular requirements for plasma installations, in the field of manufacturing engineering. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 5 December 2014 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 5 November 2015. Classification: ICS 25.180.10, CCS K61. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

Document preview — GB 5959.5-2014

National Standard of the People's Republic of China

ICS
25.180.10
Classification
K61

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Contents

  • 1 Scope1
  • 2 Normative references1
  • --- 4 design and characteristics of the device1
  • 4.1.1 General requirements1
  • 4.1.2 Circuit1
  • 4.1.3 DC arc power supply2
  • 4.1.4 torch sockets, plugs and connection cables2
  • 4.1.5 Torch2
  • 4.1.6 cooling circuit2
  • 4.1.7 manifold3
  • 4.1.8 squib3
  • 4.1.9 arc plasma system control3
  • 4.2 induction plasma system3
  • 4.2.1 General requirements3
  • 4.2.2 Circuit4
  • 4.2.3 Power4
  • 4.2.4 torch sockets, plugs and connecting cables4
  • 4.2.5 torch4
  • 4.2.6 cooling circuit4
  • 4.2.7 manifold5
  • 4.2.8 squib5
  • --- the design and characteristics of the device6
  • 5.1 General requirements6
  • 5.2 spraying equipment6
  • 5.3 heating and chemical treatment equipment 6 6 operating system and a plasma device6
  • 6.1 General requirements6
  • 6.2 Operating personnel protective equipment6
  • 6.3 Starting and stopping7
  • 6.4 Protection torch run is easy to produce toxic substances7
  • 6.5 overheat protection7
  • 6.6 Sound proof7
  • 6.7 Electromagnetic radiation protection7
  • 6.8 Particle Protection7
  • 6.9 UV radiation protection7
  • 6.10 Fire7
  • 7.1 General requirements8
  • 9 Reference10

Foreword

All technical content in this section is mandatory. GB 5959 "electric safety device" has the following 13 sections.

--- Part 1. General requirements;

--- Part 2. Particular requirements for arc furnace apparatus;

--- Part 3. Particular requirements for induction and conduction heating and induction melting apparatus means;

--- Part 4. Particular requirements for resistance heating apparatus;

--- Part 41. Particular requirements for resistance heating and melting glass heating apparatus;

--- Part 5. Particular requirements for plasma unit;

--- Part 6. Industrial microwave heating equipment safety regulations;

--- Part 7. A device having an electron gun of special requirements;

--- Part 8. Particular requirements for electroslag remelting furnaces;

--- Part 9. Particular requirements for high-frequency dielectric heating apparatus;

--- Part 10. Resistance to industrial and commercial heating systems profiling specific requirements;

--- Part 11. Liquid metal for electromagnetic stirring, transport or pouring of special equipment requirements;

--- Part 13. Electric apparatus for explosive atmosphere of special requirements. This Part replaces GB 5959.5-1991 "Safety in electroheat installations Part V. plasma equipment and other safety procedures", as compared with the latter The main changes are as follows:

1 Scope

GB 5959.5-2014 is the Chinese national standard on safety in electroheat installations-part 5: particular requirements for plasma installations, in the field of manufacturing engineering. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 5 December 2014 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 5 November 2015. Classification: ICS 25.180.10, CCS K61. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

GB 5959 safety requirements specified in this section applies to.

a) thermal plasma torch systems.

--- Arc plasma system;

--- Induction plasma system.

b) the use of means of a plasma torch system.

--- Spraying equipment;

--- Solid, liquid and gaseous charge heating and chemical treatment equipment. This section defines the security requirements for all components of the plasma torch system and apparatus using plasma torch systems, including electrical equipment Equipment, cooling lines, gas pipes, furnaces and furnace or reactor or reactor with the use of all other related equipment. The plasma torch for welding, cutting and allied processes safety and structural requirements in GB/T 15579.7-2005 specified.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 2900.23-2008 Electrotechnical terminology industrial electric equipment ( IEC 60050-841.2004, IDT)

GB 4824-2004 industrial, scientific and medical (ISM) radio-frequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement (CISPR 11.2003, IDT)

GB 5959.1-2005 Safety of electric devices - Part 1. General requirements (

IEC 60519-1.2003, IDT) Test methods

GB/T 10066.5-2014 electric installations - Part 5. electric and electrochemical devices using plasma (IEC /T S60680.2008, IDT)

3 Terms and Definitions

GB/T 2900.23-2008, terms and definitions GB 5959.1-2005 and GB/T 10066.5-2014 defined apply to this file. Safety requirements

--- 4 thermal plasma system design and equipment characteristics

4.1 arc plasma torch system

4.1.1 General requirements See GB 5959.1-2005.

4.1.2 Circuit See Chapter 6 GB 5959.1-2005. In addition, GB 5959.1-2005

6.4.1 applies to the entire device.

4.1.3 DC arc power supply The following requirements apply to the specific system of a DC arc power supply.

4.1.3.1 Power Ground DC arc power supply side of a pole (positive or negative, depending on the polarity of the torch), the system shall be used independently of the main ground wire grounding wire grounding, To avoid possible leakage current flows to the circuit, for example as a torch control circuit.

4.1.3.2 Power connection with torch When the torch is disconnected, the DC cables should be grounded through the grounding switch, in order to safely operate the torch. Before the arc ignition should be required operating procedures, can be manually locking/unlocking means to achieve (usually operated by security key) and to special Do not confirm the main circuit breaker is on line and the grounding switch has been disconnected. In addition, the operator can use the key to start the ignition eventually remove the program. This program It should comply with regulations of the country of installation.

4.1.4 torch sockets, plugs and connection cables See Chapter 8 GB 5959.1-2005.

4.1.5 torch Any design arc plasma torch has the following salient features. high-temperature gas, high pressure (usually) and liquid cooling (usually water). Therefore, for safe operation, the torch design and structure should meet the following criteria.

a) Electrical Characteristics.

--- Design between parts of the same voltage in the operation should be fixed electrical connections, including electrode holders, and ground components, To prevent overheating;

--- High voltage torch, if the leakage current flowing through the torch body exceeds 10mA, the torch should be automatically shut down;

--- Between different voltage components (especially between the electrodes) should be fixed electrical insulation, so that under normal operating conditions do not Unexpected electrical breakdown occurs.

b) cooling liquid characteristics.

--- Resistivity coolant of the cooling circuit and the torch design make different voltages member running between the electrodes in particular Maintain insulation required;

--- If the electrode breakage (accidents or normal wear and tear) appears, first electrode material through the design and/or electrodes, followed by Using the electrode detection signal to turn off the torch, so this phenomenon under control.

4.1.6 cooling circuit The following specific requirements for cooling equipment.

4.2 induction plasma system

4.2.2 Circuit See Chapter 6 GB 5959.1-2005. In addition, GB 5959.1-2005

6.4.1 applies to the entire device.

4.2.3 Power

4.2.3.1 Power Ground Supply should be independent of the main system grounding wire grounding wire to ground, to avoid possible leakage path, as indicated by the control circuit formed by the torch path.

4.2.3.2 Power connection with torch You should consider the following requirements.

a) Actions should be enclosed in a Faraday cage to reduce electromagnetic radiation and prevent operator access high-voltage terminals. If the torch cover is opened, Interlocking signals should cut off the pressure;

b) high-voltage terminal should be grounded to the housing when released when the torch or Faraday cage open or shut off the RF generator may be stored in a capacitor Where the residual charge (see

6.2.4 in GB 5959.1-2005).

4.2.4 torch sockets, plugs and connection cables You should consider the following requirements.

--- Between electrical terminal leads and between them and the ground terminal should have sufficient distance to prevent arcing;

--- To use water-cooled conductor,

6.6 GB 5959.1-2005 is applicable;

--- Avoid conductor tensile stress and small bending radius.

4.2.5 torch High-temperature gas, high pressure (usually) and liquid cooling (generally. the design of any induction plasma torch has the following salient features Water). Therefore, for safe operation, the torch design and structure should meet the following criteria.

a) Electrical Characteristics.

--- Designed for the voltage between the same parts in the operation of the electrical connection should be fixed;

--- Torch in structure or ferromagnetic metal should not be used within a Faraday cage;

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 2900.23-2008 · IEC 60050 · GB 5959.1-2005 · IEC 60519 · GB/T 10066.5-2014

Similar standards

Editions of GB 5959.5

EditionTitleRevisionStatus
GB 5959.5-2014Safety in electroheat installations-Part 5: Particular requirements for plasma installationscurrent editionCurrent
GB 5959.5-1991Safety in electroheat installations - Part 5: Specifications for safety in plasma installationsprevious editionSuperseded

This page sells the current edition, GB 5959.5-2014. Earlier editions are listed for reference only.

How to Buy GB 5959.5-2014

  1. 1Add to cart. Click the "Buy GB 5959.5-2014" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
14 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 5959.5-2014

$210.00

$180.00for partners