GB 50462-2024Standard for construction and acceptance of data center infrastructure (English PDF)

数据中心基础设施施工及验收标准

Open the GB 50462-2024 preview as PDF

Preview — first pages of GB 50462-2024 (full document: 118 pages)

This is a limited preview

Buy now to download the full PDF (118 pages)

Issued by

MOHURD; SAMR

Level / Type

National · Mandatory

Issue date

May 8, 2024

Implementation date

September 1, 2024

Scope

GB 50462-2024 is the English-translated version of 数据中心基础设施施工及验收标准.

GB 50462-2024 is the Chinese national standard for the construction and acceptance of data center infrastructure, the site execution counterpart to the data center design code. China builds data centers at a rate no other country matches, and this is the document against which the work is inspected and signed off. It covers, discipline by discipline, the indoor decoration, ceilings, partitions, floor surfaces and free access floors, walls, columns, doors and windows; the power distribution system, its electrical installations, distribution lines and lighting; the lightning protection and grounding system; the air conditioning system, its equipment, ductwork and commissioning; the water supply and drainage system; the integrated wiring and network system, cable laying, cabinet and rack installation, equipment installation and debugging; the monitoring and security system; the electromagnetic shielding system, its structure, shielding doors, accessories and the shielding effectiveness self-check; the micro modular data center; and the container data center. Each of those clauses ends with its own construction and acceptance requirements. It closes with a comprehensive test covering temperature and humidity, air particle concentration, illumination, noise, shielding, grounding resistance, power quality, radio interference and power frequency magnetic field, the wiring system, electrostatic protection, system function and the design load test, and with the completion acceptance conditions and procedures. Eleven appendices give the record sheets used throughout.

Document preview — GB 50462-2024

National Standard of the People's Republic of China

Issued by: Ministry of Housing and Urban-Rural Development of the PRC and the State Administration for Market Regulation

Contents

  • 1 General provisions1
  • 2 Terms2
  • 3 Basic requirements3
  • 3.1 Construction requirements3
  • 3.2 Materials and equipment requirements3
  • 3.3 Construction and acceptance4
  • 4 Indoor decoration5
  • 4.1 General requirements5
  • 4.2 Suspended ceiling5
  • 4.3 Partition6
  • 4.4 Ground surface8
  • 4.5 Free access floor8
  • 4.6 Interior wall, ceiling and columns9
  • 4.7 Doors, windows and other materials9
  • 4.8 Construction and acceptance11
  • 5 Distribution system12
  • 5.1 General requirements12
  • 5.2 Electric installation12
  • 5.3 Distribution line13
  • 5.4 Lighting attachment15
  • 5.5 Construction and acceptance16
  • 6 Lightning protection and grounding system18
  • 6.1 General requirements18
  • 6.2 Lightning protection and grounding equipment18
  • 6.3 Ground connection19
  • 6.4 Construction and acceptance20
  • 7 Air-conditioning system21
  • 7.1 General requirements21
  • 7.2 Air-conditioning installation21
  • 7.3 The fabrication and installation of air ducts and duct accessories22
  • 7.4 Air-conditioning system debugging23
  • 7.5 Construction and acceptance24
  • 8 Water supply and drainage system25
  • 8.1 General requirements25
  • 8.2 Pipeline installation25
  • 8.3 Experiment and acceptance26
  • 9 Integrated wiring and network system28
  • 9.1 General requirements28
  • 9.2 Cable laying28
  • 9.3 Cabinet rack installation30
  • 9.4 Equipment installation31
  • 9.5 Equipment debugging31
  • 9.6 Construction and acceptance31
  • 10 Monitoring and security system33
  • 10.1 General requirements33
  • 10.2 Piping layout and installation33
  • 10.3 Equipment installation34
  • 10.4 System debugging35
  • 10.5 Construction and acceptance35
  • 11 Electromagnetic shielding system37
  • 11.1 General requirements37
  • 11.2 Electromagnetic shielding structure construction37
  • 11.3 Electromagnetic shielding door installation38
  • 11.4 Installation of other accessories38
  • 11.5 Other construction requirements40
  • 11.6 Check of electromagnetic shielding effectiveness40
  • 11.7 Electromagnetic shielding construction acceptance41
  • 12 Micro modular42
  • 12.1 General requirements42
  • 12.2 Installation and debugging42
  • 12.3 Construction and acceptance43
  • 13 Container data center44
  • 13.1 General requirements44
  • 13.2 Installation44
  • 13.3 Debugging45
  • 13.4 Construction and acceptance45
  • 14 Comprehensive test46
  • 14.1 General requirements46
  • 14.2 Temperature and relative humidity46
  • 14.3 The air dust particle concentration47
  • 14.4 Illumination47
  • 14.5 Noise48
  • 14.6 Electromagnetic shielding48
  • 14.7 Grounding resistance48
  • 14.8 Power supply quality48
  • 14.9 Radio interference field strength and power frequency magnetic field environment49
  • 14.10 The comprehensive wiring system50
  • 14.11 Electrostatic protection50
  • 14.12 System functional testing51
  • 14.13 Design load test51
  • 15 The completion acceptance52
  • 15.1 General requirements52
  • 15.2 The completion acceptance conditions52
  • 15.3 The completion acceptance procedures53
  • Appendix A The sheet of distribution system acceptance record54
  • Appendix B The sheet of lightning protection and earthing device acceptance record55
  • Appendix C The sheet of air-conditioning system test record56
  • Appendix D The sheet of cable and optical cable cabling system performance engineering test record57
  • Appendix E The sheet of monitoring and security system function test record58
  • Appendix F The sheet of electromagnetic shielding effectiveness test record59
  • Appendix G The electromagnetic shielding room project acceptance table60
  • Appendix H The sheet of data center test record61
  • Appendix J The conformity of the project acceptance table62
  • Appendix K The compliance of the project acceptance table63
  • Explanation of wording in this standard64
  • List of quoted standards65
  • Addition: Explanation of provisions67

Foreword

This document was issued on 8 May 2024 by the Ministry of Housing and Urban-Rural Development of the PRC and the State Administration for Market Regulation and takes effect on 1 September 2024.

It is a GB standard without the /T suffix: compliance is mandatory in China.

The document runs to 118 pages. The identification, the dates, the classification and the table of contents on this page are taken from the cover and the printed contents of the standard itself.

This standard was approved by the Ministry of Housing and Urban-Rural Development of the PRC under Announcement No. 82 of 2024 and takes effect on 1 September 2024.

Its editing department is the Ministry of Industry and Information Technology of the PRC.

Eleven appendices give the acceptance record and test record sheets that the construction and acceptance process requires.

1 Scope

GB 50462-2024 is the Chinese national standard for the construction and acceptance of data center infrastructure, the site execution counterpart to the data center design code. China builds data centers at a rate no other country matches, and this is the document against which the work is inspected and signed off. It covers, discipline by discipline, the indoor decoration, ceilings, partitions, floor surfaces and free access floors, walls, columns, doors and windows; the power distribution system, its electrical installations, distribution lines and lighting; the lightning protection and grounding system; the air conditioning system, its equipment, ductwork and commissioning; the water supply and drainage system; the integrated wiring and network system, cable laying, cabinet and rack installation, equipment installation and debugging; the monitoring and security system; the electromagnetic shielding system, its structure, shielding doors, accessories and the shielding effectiveness self-check; the micro modular data center; and the container data center. Each of those clauses ends with its own construction and acceptance requirements. It closes with a comprehensive test covering temperature and humidity, air particle concentration, illumination, noise, shielding, grounding resistance, power quality, radio interference and power frequency magnetic field, the wiring system, electrostatic protection, system function and the design load test, and with the completion acceptance conditions and procedures. Eleven appendices give the record sheets used throughout.

Remaining clauses in the full document

  • 2 Terms
  • 3 Basic requirements
  • 4 Indoor decoration
  • 5 Distribution system
  • 6 Lightning protection and grounding system
  • 7 Air-conditioning system
  • 8 Water supply and drainage system
  • 9 Integrated wiring and network system
  • 10 Monitoring and security system
  • 11 Electromagnetic shielding system
  • 12 Micro modular
  • 13 Container data center
  • 14 Comprehensive test
  • 15 The completion acceptance

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 118 pages — is available in the English PDF.

Referenced standards

How to Buy GB 50462-2024

  1. 1Add to cart. Click the "Buy GB 50462-2024" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
118 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 50462-2024

$995.00

$845.00for partners