GB 5009.8-2023National food safety standard - Determination of fructose, glucose, sucrose, maltose and lactose in foods (English PDF)
Also coversGB5009.8-2023
Open the GB 5009.8-2023 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
NHC; SAMR
Level / Type
National · Mandatory
Issue date
September 6, 2023
Implementation date
September 6, 2024
Scope
GB 5009.8-2023 (National food safety standard - Determination of fructose, glucose, sucrose, maltose and lactose in foods) is available as an English-translated PDF.
GB 5009.8-2023 — This Standard specifies the methods for the determination of fructose, glucose, sucrose, maltose and lactose in foods. Method 1 - High performance liquid chromatography applies to the determination of fructose, glucose, sucrose, maltose and lactose in grains and grain products, milk and dairy products, fruits, vegetables and fruit and vegetable products, sweeteners, candies, beverages and infant foods. Method 2 - Ion chromatography applies to the determination of fructose, glucose, sucrose, maltose, and lactose in foods. Method 3 - Acid hydrolysis-Rhein-Eynon method applies to the determination of sucrose in foods. Method 4 - Rhine-Enon method applies to the determination of lactose in infant foods and dairy products. Method 1 - High performance liquid chromatography
Document preview — GB 5009.8-2023
National Standard of the People's Republic of China
Issued by: NHC; SAMR
Contents
- Foreword3
- 1 Scope4
- 2 Principle4
- 3 Reagents and materials4
- 4 Instruments and apparatuses6
- 5 Analysis steps6
- 6 Expression of analysis results8
- 7 Precision9
- 8 Others9
- 9 Principle9
- 10 Reagents and materials9
- 11 Instruments and apparatuses11
- 12 Test steps11
- 13 Expression of analysis results14
- 14 Precision14
- 15 Others14
- 16 Principle15
- 17 Reagents and solutions15
- 18 Instruments and apparatuses16
- 19 Analysis steps16
- 20 Expression of analysis results19
- 21 Precision21
- 22 Principle21
- 23 Reagents and materials21
- 24 Instruments and apparatuses22
- 25 Analysis steps22
- 26 Expression of analysis results24
- 27 Precision25
1 Scope
This Standard specifies the methods for the determination of fructose, glucose, sucrose, maltose and lactose in foods.
Method 1 - High performance liquid chromatography applies to the determination of fructose, glucose, sucrose, maltose and lactose in grains and grain products, milk and dairy products, fruits, vegetables and fruit and vegetable products, sweeteners, candies, beverages and infant foods.
Method 2 - Ion chromatography applies to the determination of fructose, glucose, sucrose, maltose, and lactose in foods.
Method 3 - Acid hydrolysis-Rhein-Eynon method applies to the determination of sucrose in foods.
Method 4 - Rhine-Enon method applies to the determination of lactose in infant foods and dairy products.
Method 1 - High performance liquid chromatography
2 Principle
The fructose, glucose, sucrose, maltose and lactose in the sample are extracted, and then separated by high performance liquid chromatography column, detected by a differential refractive index detector or an evaporative light scattering detector, and quantified by the external standard method.
3 Reagents and materials
Unless otherwise specified, all the reagents in this method are analytical reagents, and the water is grade-1 water specified by GB/T 6682.
3.1 Reagents
3.2 Preparation of reagents
3.3 Standards
3.4 Preparation of standard solutions
3.5 Materials
3.5.2 Syringe.
4 Instruments and apparatuses
4.1 High performance liquid chromatograph. equipped with a differential refractive
index detector or an evaporative light scattering detector.
4.2 Analytical balance. the sensitivity is 1 mg and 10 mg.
4.3 Vortex mixer.
4.4 Centrifuge. speed >= 4 000 r/min.
4.5 Ultrasonic cleaner.
4.6 Sample crushing equipment. high-speed crusher.
4.7 Constant-temperature drying oven.
4.8 Constant-temperature water bath device.
5 Analysis steps
5.1 Sample pretreatment
5.1.2 Sample extraction
5.1.3 Purification
For the above sample extract solution, use a filter paper to filter (discard the primary filtrate) or centrifuge to obtain the supernatant; then, use a 0.45 um water-based membrane syringe to filter into a sample bottle for analysis by a high-performance liquid chromatograph.
5.2 Apparatus reference conditions
Apparatus reference conditions are as below.
90 °C; nitrogen flow rate 2.5 L/min.
5.3 Preparation of the standard curve
Inject the mixed standard working solution into the high-performance liquid chromatograph in order from low to high concentration, and measure the corresponding peak areas or peak heights of fructose, glucose, sucrose, maltose and lactose. For the differential refractive index detector, use the concentration of the standard working fluid as the abscissa and the peak area or peak height as the ordinate to draw a standard curve;
5.4 Determination of sample solution
Inject the sample solution into the high-performance liquid chromatograph;
qualitatively record the peak area or peak height of the target substance based on the retention time; obtain the concentrations of fructose, glucose, sucrose, maltose and lactose in the sample solution based on the standard curve.
5.5 Blank test
Except that no sample is added, proceed according to the above steps.
6 Expression of analysis results
Calculate the contents of fructose, glucose, sucrose, maltose and lactose in the sample according to Formula (1).
7 Precision
The absolute difference of 2 independent test results obtained under repeatability cannot exceed 10% of the arithmetic mean value.
8 Others
When the weighing sample is 10 g and the fixed volume is 100 mL, the method detection limits for fructose, glucose, sucrose, maltose and lactose are all 0.2 g/100 g, and the quantification limits are all 0.5 g/100 g.
9 Principle
After extraction and purification, the fructose, glucose, sucrose, maltose and lactose in the sample are separated by an ion chromatography column, detected by a pulse ampere detector, and quantified by the external standard method.
10 Reagents and materials
Unless otherwise specified, all the reagents in this method are analytical reagents, and the water is grade-1 water specified by GB/T 6682.
10.1 Reagents
10.1.1 Sodium hydroxide (NaOH). chromatographic pure.
10.1.2 Glacial acetic acid (CH3COOH).
10.2 Preparation of reagents
10.3 Standards
10.3.1 Fructose (C6H12O6, CAS number. 57-48-7). purity >=99%, or standard material
certified by the country and awarded a standard material certificate.
10.3.2 Glucose (C6H12O6, CAS number. 50-99-7). purity >=99%, or standard material
certified by the country and awarded a standard material certificate.
10.4 Preparation of standard solution
10.5 Materials
10.5.1 0.45 um water-based membrane syringe filter (except cellulose membrane).
10.5.2 Purification column. C18 solid-phase extraction cartridge (1.0 mL) or one with
equivalent performance.
10.5.3 Syringe.
11 Instruments and apparatuses
11.1 Ion chromatograph. equipped with pulse ampere detector.
11.2 Sample crushing equipment. high-speed crusher.
11.3 Ultrasonic cleaner.
11.4 Analytical balance. sensitivity 1 mg.
11.5 Vortex mixer.
11.6 Centrifuge. speed >= 4 000 r/min.
11.7 Constant-temperature drying oven.
11.8 Constant-temperature water bath device.
12 Test steps
12.1 Sample pretreatment
12.1.1 Sample preparation
Take an appropriate amount of representative sample; for drinks and other liquid homogeneous samples, shake directly; for non-uniform samples, homogenize or crush evenly; for frozen drinks, melt at room temperature, stir thoroughly and, if necessary, heat and stir in a water batch at 30 °C ~ 40 °C; for sauces, grind or homogeneously mix;
for chocolate, heat and melt in a water bath at 50 °C ~ 60 °C, and stir thoroughly while it is hot.
12.1.2 Sample extraction
12.1.3 Sample purification
The sample extraction solution can be diluted by an appropriate multiple according to the target sugar content in the sample. When detecting lactose in infant formula milk powder, dilute it 1 000 times and then purify it; when detecting high sugar content in honey and candy, dilute it 500 times and then purify it.
After filtering or centrifuging the above sample extraction solution or dilution solution to obtain the supernatant, pass it through a 0.45 um aqueous membrane syringe filter and a C18 solid phase extraction cartridge (1.0 mL) in sequence; discard the first 3 mL;
collect subsequent eluates for testing.
12.2 Apparatus reference conditions
Apparatus reference conditions are as below.
12.3 Drawing of standard working curve
Inject the mixed standard working solution into the ion chromatograph in order from low to high concentration, and measure the corresponding peak areas of fructose, glucose, sucrose, maltose and lactose. Taking the concentrations of fructose, glucose, sucrose, maltose and lactose in the standard working solution as the abscissa and the peak area as the ordinate, draw the standard curves, respectively. See Appendix B for the ion chromatograms of standard solutions of fructose, glucose, sucrose, maltose and lactose.
12.4 Determination of sample solution
Inject the sample solution into the ion chromatograph, identify it based on the retention time, record the peak area, and obtain the concentrations of fructose, glucose, sucrose, maltose and lactose in the sample solution based on the standard curve.
12.5 Blank test
Except that no sample is added, proceed according to the above steps.
13 Expression of analysis results
Calculate the contents of fructose, glucose, sucrose, maltose and lactose in the sample according to Formula (2).
14 Precision
The absolute difference of 2 independent test results obtained under repeatability cannot exceed 10% of the arithmetic mean value.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
How to Buy GB 5009.8-2023
- 1Add to cart. Click the "Buy GB 5009.8-2023" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 5009.1-2025 — National food safety standard - Physical and chemical testing - General principles
GB 5009.11-2024 — National food safety standard - Determination of total arsenic and inorganic arsenic in food
GB 5009.111-2016 — National food safety standard - Determination of deoxynivalenol and its acetylated derivatives in food
Secure payment via Stripe
Payments accepted
GB 5009.8-2023