GB 29993-2013Rubber and/or plastics hoses and hoses assemblies for domestic gas-technical requirements and testing methods (English PDF)
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for GB 29993-2013 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Mandatory
Issue date
November 27, 2013
Implementation date
December 1, 2014
Scope
GB 29993-2013 (Rubber and/or plastics hoses and hoses assemblies for domestic gas-technical requirements and testing methods) is available as an English-translated PDF.
GB 29993-2013 — This standard specifies the household gas Rubber and plastic hoses and hose assemblies of structures and materials, dimensions and tolerances, appearance, technical article Items and evaluation methods, test frequency, marking, packaging, transportation, storage and use.
This standard applies to the use of ambient temperature of -10 °C ~ 70 °C, working pressure of 3.3kPa or less low-pressure gas town gas switch and between burning appliances, as well as between domestic bottled liquefied petroleum gas regulator and the burner connected with rubber and plastic hose (hereinafter referred to as Hose) and hose assemblies.
Found what you need?
Document preview — GB 29993-2013
National Standard of the People's Republic of China
- ICS
- 83.140.40; 97.040.20
- Classification
- G 42
Issued by: Standardization Administration of China
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Basic technical requirements
- 4 Hose Performance and Evaluation Method
- 5 Test Frequency
- 6 3 logo
- 7 Packaging, transportation, storage and use
- Appendix A (normative) gas resistance test
- Appendix B (normative) Resistance test liquid
- Annex C (normative) flame test
- Annex D (normative) resistance to gas permeability test
- Appendix E (normative) Test softness
- Annex F (normative) type test and routine test production of the hose
- Annex G (informative) production test
Foreword
The standard of Chapters 4 and 6 are mandatory, the rest are recommended.
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard proposed by China Petroleum and Chemical Industry Association.
This standard by the National Rubber and rubber products hose Standardization Technical Committee Technical Committee (SAC/TC35/SC1) centralized.
This standard was drafted. Suzhou fourth Rubber Co., Ltd., Wuxi City Qian function Plastic Co., Ltd. Shenyang Product Quality Supervision and Inspection Institute experience, Shenyang Rubber Research and Design Institute.
1 Scope
This standard specifies the household gas Rubber and plastic hoses and hose assemblies of structures and materials, dimensions and tolerances, appearance, technical article Items and evaluation methods, test frequency, marking, packaging, transportation, storage and use.
This standard applies to the use of ambient temperature of -10 °C ~ 70 °C, working pressure of 3.3kPa or less low-pressure gas town gas switch and between burning appliances, as well as between domestic bottled liquefied petroleum gas regulator and the burner connected with rubber and plastic hose (hereinafter referred to as Hose) and hose assemblies.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 1690 vulcanized rubber or thermoplastic rubber Test method for resistance to liquids GB/T 2941 rubber physical test method for preparing and conditioning General Procedure GB/T 3512 vulcanized rubber or thermoplastic rubber hot air and heat accelerated aging test GB/T 5563 Rubber and plastics hoses and hose assemblies - Hydrostatic testing GB/T 5564-2006 Rubber and plastic hoses low Flexing Test GB/T 5565-2006 rubber or plastic hose reinforced and non-reinforced hose bending test GB/T 9573 Rubber and plastics hoses and hose assemblies size measurement method GB/T 9576 Rubber and plastics hoses and hose assemblies for selection, storage, use and maintenance guide GB/T 9577 Rubber and plastics hoses and hose assemblies marking, packaging and transport rules GB/T 24134-2009 Rubber and plastics hoses resistance under static conditions evaluate ozone resistance HG/T 2185 Rubber hose appearance quality
3 Basic technical requirements
3.1 Hose Construction
Hose is structured as follows.
a) hose structure may be a single layer or multiple layers (including armored hose);
b) a single-layer structure hose (hose pure) black multilayer structure hose outer cover layer is orange, can also be customized.
3.2 Dimensions and tolerances
When measured according to GB/T 9573 method, unless otherwise specified, hose dimensions and tolerances shall comply with the requirements in Table 1.
Table 1 hose dimensions and tolerances
Nominal inner diameter Inner and tolerance mm Wall thickness and tolerances mm Hose with metal protection hose 9.0 9.0 ± 0.4 3.0 ± 0.3 > 1.5 9.5 9.4 ± 0.4 3.0 ± 0.3 > 1.5 13 12.7 ± 0.5 3.3 ± 0.3 > 1.8
3.3 Materials
3.3.1 hose material shall conform to the requirements specified in Table 2.
Material requirements and test methods in Table 2 project Claim Outer liner cladding layer tubing -experiment method Aging properties of 70 °C ± 1 °C, 96h Tensile strength change rate /% <= Elongation at break change rate /% <= GB/T 3512 Gas resistant performance the rate of mass change /%, <= 353 535 Appendix A
3.3.2 All samples should be intercepted on the hose, from the hose when not intercept, should use the same degree of vulcanization curing specimens tested, Selection of type 3 dumbbell specimens.
3.3.3 hose material and its intended use of the rubber, plastics and reinforcing layer material.
3.4 Appearance
Unless otherwise specified, the hose appearance quality should be consistent with the provisions of HG/T 2185's.
4 Hose Performance and Evaluation Method
4.1 when tested in accordance with Appendix B, hose fluid resistance must meet the requirements of Table 3.
Table 3 hose resistance to liquids
Project requirements, test methods Detergent resistant quality change rate /% High-temperature cooking oil quality change rate /% Resistant oil quality change rate /% Vinegar mass resistance change rate /% Soap mass resistance change rate /% <=5 <=3 <=3 <=5 <=5 Appendix B
4.2 When the method according to GB T 24134-2009 1 is resistance to ozone aging test/subject 96h, visual inspection, no cracking phenomenon.
4.3 When the flame test carried out in accordance with Annex C, the sample continued to burn time should not exceed 5s.
4.4 When carried out according to Annex D resistant gas permeation test, equal to the nominal inside diameter of less than 9.5 Hose gas not larger than 5mL/h, public He said inner diameter of the gas hose 13 is not larger than 7mL/h.
4.5 Take 1m long hose or a hose assemblies for the tightness test samples, one end plugged into the free end and the other end of the pump or gas source is connected to the sample immersed in water, and gradually into the inflatable tube to test pressure 100kPa maintain 1min, the sample should be no leakage Anomalies.
4.6 When in accordance with GB/T 5565-2006 A method for bending test, the minimum bend radius of 5 times the nominal inner diameter, T/D should not be Less than 0.9.
4.7 take about 500mm hose to heat test samples, placed in a temperature (100 ± 2) °C incubator 48h, after removing the at room temperature for 30min ~ 40min after the tightness test performed according to 4.5, no leaks and other anomalies.
4.8 When the test in accordance with Appendix E were soft, the contact angle of the sample hose and the cylinder must be greater than 110 °.
4.9 When the pressure test to verify method according to GB/T 5563 stipulated. Test pressure 200kPa, maintaining 30s, the hose should be no leakage Dew or damage.
4.10 take a long hose or hose assemblies 120mm for breaking test samples, the sample symmetrically sandwiched tensile testing machine on the upper and lower gripper, start testing machine, tensile rate (100 ± 10) mm/min, the sample was stretched to breaking maximum tensile force of not less than 0.6kN.
4.11 When the press GB/T 5564-2006 Method B low temperature bending test, test temperature (-10 ± 2) °C, 10 times the nominal After an internal diameter of minimum bend radius bending test, without cracks and other anomalies. The sample to be returned to ambient temperature (not less than 3h) Then 4.5 tightness test, without leaks and other anomalies.
5 Frequency of testing
Type test and routine test shall comply with the provisions of Appendix F.
Type tests are those tests to be confirmed by the particular method with a specific material hose meets all the requirements of this standard carried out. That the test shall be intervals not exceeding five years, or when changes in manufacturing methods or materials are repeated in. The test shall be in all sizes, all categories and type Do not be on, except for the size and structure of the same person.
Routine tests are those tests before shipment on each batch of the finished hose.
Production tests are those for the control of production quality and should implement the tests given in Annex G. Appendix G for the given frequency only guide.
6 Logo
Continuous length of the hose every 300mm single hose or represents at least the following.
a) product name, size;
b) manufacturer's name or abbreviation;
c) product standards;
d) manufacturing quarter and year;
e) life.
7 Packaging, transportation, storage and use
7.1 Packaging
7.1.1 hose coiled packaged in clear plastic bags inside the hose or other energy efficient protective packaging materials, the inner diameter of coil should Less than 15 times the inner diameter of the hose.
7.1.2 must be accompanied within each package product certification and product brochures, product instructions shall contain at least the following applies content.
a) the use of hose length should not exceed 2m, and may not have an interface; when the temporary use of hose may be less than 5m;
b) hose clamp connections should be fixed;
c) hose or hose assemblies must not pass through walls, ceilings, floors, windows and doors use;
d) the installation, the bending radius should be larger than 50mm, ban on sale, stretching, twisting, use of state under pressure;
e) should be installed below the height of the cooktop, do not close to the flame to avoid fire hose baking accelerated aging;
f) the appearance of the hose should be checked regularly and joints for leaks and replace if signs of aging in a timely manner;
g) sets GB/T 9576 stipulated storage conditions of the relevant provisions;
h) hose and use of the storage period.
7.2 Transport, storage and use
7.2.1 Transport hose and hose assemblies, storage should be consistent with GB T 9576 and GB/T requirements/9577's.
7.2.2 In line with GB/T 9576 storage conditions, storage period of not more than one year, the use of a period not exceeding three years.
Appendix A
(Normative)
Gas resistance test
When A.1 gas resistance test carried out in the hose lining layer (overcoat layer) on a selected width 10mm, length 50mm, 2mm thick specimens, with the Figure A.1 Test device shown at a test temperature of 35 °C ± 2 °C, put the sample in a purity of more than 98% of n- pentane gas saturated environment.
Holding 48h after removing dried and placed in a container of about 240mm in diameter, the holding at room temperature for about 60min. Then within 30min Measuring the quality of the sample, according to the formula (A.1) calculates the rate of mass change.
deltam =
m2-m1
100% (A.1)
Where.
deltam --- rate of mass change,%;
After m2 --- quality gas resistance test in grams (g);
Mass before m1 --- gas resistance test in grams (g).
Explanation.
1 --- sample;
2 --- drying vessel;
3 --- incubators;
4 --- bolt;
5 --- gasket;
6 --- cover;
7 --- n- pentane.
Figure A.1 gas resistance test device
Appendix B
(Normative)
Fluid resistance test B.1 hose taken from a sample of about 50mm will be liquid resistant test, carried out in accordance with the provisions of GB/T 1690, and to calculate the mass change rate. Test conditions are given in Table B.1.
Soaking samples at both ends to prevent installation of the plug to prevent the liquid soaking into the interior of the specimen.
Table B.1 fluid resistance test conditions
Pilot projects
Test conditions
Soaking solution
Test temperature
Test time
Detergent Resistance 2% n- Aqueous sodium dodecylbenzenesulfonate 25 ± 5 24h Soybean oil temperature of 155 ± 5 10s Resistance of soybean oil Resistance of 4% aqueous solution of acetic acid in vinegar Soap resistance of 2% aqueous solution of sodium dodecyl 25 ± 5 24h Appendix C (Normative) Flame test C.1 take about 250mm hose to make a sample. As shown in Fig C.1 crater inner diameter of 10mm Bunsen burner flame length about 40mm, the sample was placed horizontally in place flame tip about 10mm (about 800 °C) distance, after 5s, Bunsen burner flame goes out, Determination of the average time of sample continued to burn, take three samples represent.
Explanation.
1 --- sample;
2 --- Bunsen burner;
3 --- gas.
Figure C.1 flame test apparatus
Appendix D
(Normative)
Gas permeability test resistance D.1 Overview this annex specifies the test apparatus and test method of resistance to gas permeation test.
D.2 test device
The constant temperature water bath temperature was adjusted to 35 °C ± 0.2 °C, it is best to propane gas cylinders and piping together 4 thermostatic water tank, or the air Bottles and placed in the pipe section 35 °C ± 0.5 °C thermostatic chamber, the test device shown in Figure D.1.
Explanation.
1 --- flat-bottomed flask;
2 --- aspirator;
3 --- water manometer;
4 --- propane cylinders;
5 --- mercury manometer;
6 --- section of the door;
7 --- section of the door;
8 --- cylinder;
. 9 --- auxiliary flat-bottomed flask;
10 --- stopper;
. 11 --- sample;
12 --- section of the door;
13 --- gauge;
14 --- pressure regulator;
15 --- links section of the door;
16 --- heated water tank.
Figure D.1 resistance to gas permeation test apparatus
D.3 Test Method
Select the length of the hose 900mm made sample, plug one end with a plug, the other end of the flat-bottomed flask 1 through a glass tube stoppers (Figure D.1). Under 200kPa pressure conditions, check the joints and plugs in water or without leakage phenomenon later. Dry the surface of the sample and Other parts of the water, and then re-cork stopper and the sample on the flask 1, and you should be careful not to get off the sample.
Getter 2 is filled with a concentration of 20% salt water, water manometer 3 to inject gas saturated with distilled water. The heated water tank regulator to (35.0 ± 0.2) °C, at least after 2h, the extracted air with a vacuum pump within the sample, then supply gas with gas bottles 4 (concentration of 98% Propane), so that the internal pressure of the sample holding mercury manometer 5 60kPa, the situation in the closed section of the door 6, by a gas-permeable, water column pressure 3 level gauge will change, opening the door section 7, so that the aspirator 2 salt water flows into the cylinder 8, by this method, so that the water column pressure 3 equal level gauge.
By volume of saline cylinder 8 measurement, equal to the amount of gas from the inside volume of the sample is transmitted. 22h after the start of the test section of the door 6 is open, then close the door section 6, measured by volume, with a few milliliters per hour from the first through to the first 30h 24h within this gas 6h (ML/h) is represented.
Appendix E
(Normative)
Flexibility test
When E.1 hoses softness test by the test apparatus shown in Fig. E.1, test conditions in Table E.1 select a predetermined length of hose Sample, the sample was placed on a corresponding cylinder, at both ends of the specimen suspension tables E.1 predetermined mass objects, 1min after the measurement sample hose Contact angle of the cylinder.
Explanation.
1 --- sample;
2 --- cylinder;
3 --- hangings;
4 --- contact angle.
Figure E.1 softness test device
Table E.1 softness test conditions
Nominal inner diameter Sample length mm Diameter of the cylinder mm Pedants quality kg 9.0 400 140 1.0 9.5 400 140 1.0 13,500,180 1.5 Appendix F (Normative) Production hose type test and routine test F.1 finished hose type test and routine test items and frequency are given in Table F.1 in.
Table F.1 type test and routine test
Project type test routine test Dimensions and tolerances Diameter and tolerance × a × Wall thickness and tolerances × × Appearance × × material Aging × N/Ab Gas resistance test × N/A hose Fluid resistance test Detergent resistance × N/A High temperature oil resistance × N/A Resistance oil resistance × N/A Vinegar of resistance × N/A Resistance of soap × N/A Ozone resistance × N/A Flame test × N/A Resistance to gas permeability × N/A Tightness × × Bending property × N/A Heat resistance × N/A Softness (only for metal protection hose) × N/A Pressure resistance × × Hoses to pull off the performance of × × Low temperature flexibility × N/A
Note 1. The hose appearance, size should test by the root;
Note 2. Each 50000m products, each batch optionally one specification is represented either take two detection tightness, pressure hose and pull off the performance, lack of Batch, test once a week.
a × shows the test should be carried out;
b N/A indicates not applicable test.
Appendix G
(Informative)
Production Test
Production pilot project G.1 recommendations and batch Table G.1.
Table G.1 production test
Project batch test a periodic test b Dimensions and tolerances Diameter and tolerance × c × Wall thickness and tolerances × × Appearance × × material Aging N/Ad × Gas resistance test N/A × hose Fluid resistance test Detergent Resistance N/A × Oil of high temperature N/A × Resistance to oil resistance N/A × Vinegar resistance of N/A × Soap resistance of N/A × Ozone resistance N/A × Flame test N/A × Resistance to gas permeation performance N/A × Tightness × × Bending Properties N/A × Heat resistance N/A × Softness (only for metal protection hose) N/A × Pressure resistance × × Hoses to pull off the performance of × × Low temperature flexibility N/A × a specification of each product per 50000m test a sample;
b specifications of each product every 12 months, three test samples;
c × shows the test should be carried out;
d N/A indicates not applicable test.
twenty one
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1690Rubber, vulcanized or thermoplastic—Determination of the effect of liquids
- GB/T 2941Rubber - General procedures for preparing and conditioning test pieces for physical test methods
- GB/T 3512Rubber, vulcanized or thermoplastic -- Accelerated ageing and heat resistance tests -- Air-oven method
- GB/T 5563Rubber and plastics hoses and hose assemblies - Hydrostatic testing
- GB/T 5564-2006Rubber and plastics hoses -- Sub ambient temperature flexibility tests
- GB/T 9573Rubber and plastics hoses and hose assemblies -- Methods of measurement of the dimensions of hoses and the lengths of hose assemblies
GB/T 5565-2006 · GB/T 24134-2009 · HG/T 2185
How to Download GB 29993-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 1690-2010 — Rubber, vulcanized or thermoplastic—Determination of the effect of liquids
GB/T 16900.2-2020 — Rules for the presentation of graphical symbols - Part 2: Method for testing comprehensibility
GB/T 16900-2008 — Rules for the presentation of graphical symbols - General principles
Secure payment via Stripe