GB 26572-2025Requirements for Restricted Use of Hazardous Substances in Electrical and Electronic Products (English PDF)
电气电子产品有害物质限制使用要求
Open the GB 26572-2025 preview as PDF
This is a limited preview
Buy now to download the full PDF (18 pages)
Issued by
SAMR / SAC
Level / Type
National · Mandatory
Issue date
August 1, 2025
Implementation date
August 1, 2027
Scope
GB 26572-2025 is the English-translated version of 电气电子产品有害物质限制使用要求.
Specifies concentration limits, compliance testing methodologies, and marking requirements for restricted hazardous substances (lead, mercury, cadmium, hexavalent chromium, PBBs, PBDEs) in electrical and electronic products. China's equivalent of the EU RoHS directive.
Document preview — GB 26572-2025
National Standard of the People's Republic of China
- ICS
- 31.020
- Replacing
- GB/T 26572-2011
Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China.
Contents
- Foreword2
- Introduction3
- 1 Scope4
- 2 Normative References4
- 3 Terms and Definitions4
- 4 Classification of Electrical and Electronic Products
- 5 Limit Requirements7
- 6 Marking Requirements8
- 7 Implementation of the Standard13
- Appendix A List of Hazardous Substances Restricted for
- Appendix B Marking Graphic Specifications
- Appendix C Marking Interpretation and Color Description
- Bibliography18
Foreword
This Document was drafted as per the rules specified in GB/T 1.1-2020 Directives for Standardization – Part 1: Rules for the Structure and Drafting of Standardizing Documents.
This Document replaced GB/T 26572-2011 Requirements of Concentration Limits for Certain Restricted Substances in Electrical and Electronic Products, and its No.1 Amendment. Compared with GB/T 26572-2011, the major technical changes of this Document are as follows besides the structural adjustments and editorial modifications:
a) Delete the terms and definitions of "restricted substances" (see 3.1 of the 2011 Edition);
b) Add four terms and definitions: "hazardous substance," "environment-friendly use period," "catalogue for compliance management of restricted use of hazardous substances in electrical and electronic products," and "exemption" (see 3.2, 3.6, 3.7, and 3.8 of this Edition);
c) Add the classification of electrical and electronic products and the requirements for restricted use of hazardous substances (see Clause 4 of this Edition);
d) Add marking requirements (see Clause 6 of this Edition);
e) Delete the disassembly of electrical and electronic products (see Appendix A of Please note some contents of this Document may involve patents. The issuing agency of this Document shall not assume the responsibility to identify these patients.
This Document was proposed by and under the jurisdiction of Ministry of Industry and Information Technology of the People’s Republic of China.
The historical editions replaced by this Standard are as follows:
--- It is first-time revised hereby.
Introduction
This Document has been formulated with reference to relevant international standards, regulatory requirements, and industry practices in order to implement the relevant requirements of Measures for the Administration of the Restricted Use of the Hazardous Substances Contained in Electrical and Electronic Products and Implementation Arrangements for the Conformity Assessment System for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products; control and reduce the pollution to the environment and harm to human health caused by discarded electrical and electronic products; promote clean production and comprehensive resource utilization in the electrical and electronic industry; encourage green consumption; protect the environment and human health; enhance the awareness and level of green production among electrical and electronic enterprises; and promote high-quality development of the industry.
1 Scope
This Document specifies the requirements for limits and labeling of hazardous substances in electrical and electronic products.
This Document applies to electrical and electronic products manufactured, sold, and imported within the territory of the People's Republic of China.
2 Normative References
The provisions in following documents become the essential provisions of this Document through reference in this Document. For the dated documents, only the versions with the dates indicated are applicable to this Document; for the undated documents, only the latest version (including all the amendments) is applicable to this Document.
3 Terms and Definitions
3.1 Electrical and electronic products
Equipment and related products that operate on electric current or electromagnetic fields, or are intended to generate, transmit, or measure electric current or electromagnetic fields, with a rated operating voltage not exceeding 1500 V DC or 1000 V AC.
3.3 Homogeneous materials
A material composed of one or more substances that is uniform in all its
3.4 Components
A structural unit in electrical and electronic products that has a certain function or purpose.
3.5 Test units
Samples that are submitted directly for testing without further analysis.
3.6 Environmental-friendly use period
The period during which hazardous substances contained in electrical and electronic products will not leak or mutate, and will not cause serious environmental pollution or serious damage to personal health or property when used normally in accordance with the product instructions.
NOTE 1: The environment-friendly use period is generally measured in years.
NOTE 2: The environment-friendly use period for electrical and electronic products begins on the date of production.
NOTE 3: "Contains" means the content of restricted hazardous substances in the product
3.7 Catalogue for compliance management of restricted use of hazardous
A product catalogue developed for the implementation of the management of the restricted use of hazardous substances in electrical and electronic products.
NOTE 1: It includes the categories of electrical and electronic products, the types of hazardous substances restricted for use, the restricted use period, and exception requirements.
NOTE 2: This catalogue is issued or updated by the competent authority for the restricted use of hazardous substances in electrical and electronic products. The catalogue for compliance management of restricted use of hazardous substances in the first batch of electrical and electronic products can be found in Bibliography [4].
4 Classification of Electrical and Electronic Products
The classification of electrical and electronic products and requirements for restricted use of hazardous substances can refer to the provisions of Table 1.
Products that are listed into the Catalogue for Compliance Management of Restricted Use of Hazardous Substances in Electrical and Electronic Products They shall meet the Category II Products that are not listed into the Catalogue for Compliance Management They shall meet the requirements in Clause 6 a of Restricted Use of Hazardous Substances in Electrical and Electronic Products a Category II electrical and electronic products are encouraged to comply with the limit requirements in Clause 5, as shown in the Measures for the Administration of the Restricted Use of the Hazardous Substances Contained in Electrical and Electronic Products.
5 Limit Requirements
5.1 Limit value requirements
The categories of hazardous substances restricted for use in the homogeneous materials that constitute electrical and electronic products and their limits shall meet the requirements of Appendix A.
5.2 Test methods
The determination of hazardous substances in electrical and electronic products shall be conducted according to the methods in the corresponding parts of GB/T 39560 (all parts).
5.3 Compliance judgement requirements
5.3.1 Classification and Requirements of test units
When testing according to the test method in 5.2, the electrical and electronic products shall be disassembled into test units according to the procedures and requirements of GB/T 39560.2, following the principle of disassembling them into homogeneous materials as much as possible. These test units shall then be classified according to Table 2. […]
5.3.2 Compliance judgement rules
When the test results for hazardous substances in all test units of an electrical and electronic product disassembled according to the requirements of 5.3.1 meet the requirements of Table 3, the product shall be judged to meet the requirements of 5.1. If the test results for hazardous substances in any test unit do not meet the requirements of Table 3, the product shall be judged not to meet the requirements of 5.1.
a Hexavalent chromium (Cr(VI)) testing results in accordance with the method specified in GB/T
39560.701 are “Negative for hexavalent chromium [Cr(VI)]”.
b Test units subject to exemption shall be implemented according to the corresponding requirements in the published exemption list.
6 Marking Requirements
6.1 General requirements
6.1.1 Producers or importers of electrical and electronic products shall mark the hazardous substances contained in their products in accordance with the requirements of this Clause.
6.1.2 Products purchased for production support may not be marked with the restricted use of hazardous substances in electrical and electronic products. In this case, the supplier shall provide all required information for marking upon the purchaser's request.
NOTE: "Products purchased for production support" generally refer to components, materials, and other products purchased by a manufacturer from its supplier for the production of a specific product. These components or materials are not sold directly to consumers.
6.1.3 Spare parts used for after-sales service such as repairs, returns, and exchanges of sold electrical and electronic products may not be marked with the restricted use of hazardous substances in electrical and electronic products. In this case, the supplier shall maintain the information technology supporting documentation for the hazardous substance content of the spare parts in accordance with the requirements of 6.5.
6.4 Marking requirements
6.4.1 Generally, manufacturers or importers of electrical and electronic products shall mark the markings shown in Figure 1 or Figure 2 directly on a visible part of the product by molding, laser engraving, spraying, pasting, or printing. The markings must be clearly legible, non-fading, and difficult to remove. If digital marking is used, the requirements in 6.4.5 shall apply. 6.4. […]
6.5 Document retention
7 Implementation of the Standard
For products manufactured or imported before the implementation date of this Document, the requirements of this Document shall be implemented starting from the 13th months after the implementation date.
a CAS number is the registration number established by the Chemical Abstracts Service (CAS) for chemical substances.
Appendix A List of Hazardous Substances Restricted for
The list of hazardous substances restricted for use in electrical and electronic products and their limits shall comply with the provisions of Table A.1.
Appendix B Marking Graphic Specifications
The marking graphic specifications for the restricted use of hazardous substances in electrical and electronic products shall comply with the following provisions.
a) Mark I: Graphic specifications shall be in accordance with Figure B.1 (grid size b) Mark II: Graphic specifications shall be in accordance with Figure B.2 (grid 1) The numeral font shall be Impact;
Appendix C Marking Interpretation and Color Description
C.1 Marking interpretation
The marking connotation of the restricted use of hazardous substances in electrical and electronic products includes three portions: whether the electrical and electronic product contains hazardous substances, the environment-friendly use period of the electrical and electronic product, and whether the electrical and electronic product is recyclable.
Mark I is generally green, indicating that the product does not contain hazardous substances. The letter "e" in the middle of the graphic represents electrical and electronic products and environmental protection, symbolizing green and environment-friendly electrical and electronic products. The lines with arrows forming a circular circle outside the graphic indicate that the electrical and electronic product is recyclable. The entire graphic indicates that the electrical and electronic product does not contain hazardous substances and is a green and environment-friendly product.
Mark II is typically orange, indicating that the product contains hazardous substances. A replaceable number appears in the center of the graphic, clearly indicating the environmentfriendly use period for the electrical and electronic product. The lines with arrows forming a circular circle outside the graphic indicate that the electrical and electronic product is recyclable. The entire graphic conveys the message that, although the electrical and electronic product contains hazardous substances, it can be safely used within the environment-friendly use period.
C.2 Color description
For Mark I, if green is used, the four primary color values for printing (C:85, M:30, Y:85, K:20) should be used.
For Mark II, if orange is used, the four primary color values for printing (C:0, M:75, Y:100, K:0) should be used.
Bibliography
[1] SJ/Z 11388 General Guidelines of Environment-friendly Use Period of Electronic Information Products [2] SJ/T 11692 Guideline of sample disjointment for testing certain restricted substances in electrical and electronic products [3] Measures for the Administration of the Restricted Use of the Hazardous Substances Contained in Electrical and Electronic Products (2016 No.32 Order of Ministry of Industry and Information Technology of People’s Republic of China) https://www.miit.gov.cn/zcfg/dzl/art/2016/art_45d8278853d84a81b26ff031cc4a1ebb.ht ml [4] Catalogue for Compliance Management of Restricted Use of Hazardous Substances in Electrical and Electronic Products (First Batch) and List of Exemption of Compliance Management List ([2018 No.15] Notification of the Ministry of Industry and Information Technology of the People’s Republic of China)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Referenced standards
Cited by
- GB 46859-2025Technical requirements for safety and security of children's watches
- GB/T 46491-2025Complementary food machines for infant
- GB/T 46730-2025Specification for the use of recycled materials of household electrical appliances
- GB/T 46737-2025Guidance for the evaluation of zero-carbon factories in the electrical and electronic industry
How to Buy GB 26572-2025
- 1Add to cart. Click the "Buy GB 26572-2025" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB TEST-1 — Test card — preview without a stored file
GB 11118-2026 — Hydraulic fluids (L-HL, L-HM, L-HV, L-HS and L-HG type)
GB 23200.121-2026 — National food safety standard - Determination of 352 pesticides and metabolites residues in foods of plant origin - Liquid chromatography-tandem mass spectrometry method
$205.00
USD · One-time purchase
Secure payment via Stripe
Payments accepted
GB 26572-2025
$205.00