Valid

GB 24389-2009Noise limits for shearing machinery (English PDF)

剪切机械 噪声限值

Preview PDF

This is a limited preview

Buy now to download the full PDF (5 pages)

Need quotation for your management?

Get a formal quotation for GB 24389-2009 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Mandatory

Issue date

September 30, 2009

Implementation date

July 1, 2010

Scope

GB 24389-2009 is the English-translated version of 剪切机械 噪声限值.

GB 24389-2009 — This standard specifies the shear mechanical sound power level and sound pressure level of the noise limits. This standard applies to mechanical shear, including various types of bar shears, alligator shears,, punching shears, United punching Shears.

Found what you need?

Document preview — GB 24389-2009

National Standard of the People's Republic of China

ICS
25.120.10
Classification
J 62

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Noise limits
  • 3.1 Bar shears noise limits
  • 3.4 Punching shear noise limits
  • 3.5 Ironworkers noise limits
  • 4 Measurement
  • 4.1 SPL Measurement
  • 4.2 Sound power level measurement
  • 4.3 Noise Measurement Description

Foreword

3.1.1,3.2.1,3.3.1,3.4.1,3.5.1 this standard, as recommended in Chapter 4, the other mandatory.

The standard proposed by China Machinery Industry Federation.

This standard by the National Forging Machinery Standardization Technical Committee.

1 Scope

This standard specifies the shear mechanical sound power level and sound pressure level of the noise limits.

This standard applies to mechanical shear, including various types of bar shears, alligator shears,, punching shears, United punching Shears.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 23281-2009 forging machinery noise level measurement method GB/T 23282-2009 forging machinery sound power level measurement

3 Noise limits

Shear mechanical noise into sound power level, sound pressure level requirements, and according to the type of cutting machine are given noise limits.

3.1 Bar shears noise limits

3.1.1 Bar shears sound power level limits

Bar shears during continuous idling noise A-weighted sound power level LWA shall not exceed specified in Table 1.

Table 1

Nominal force bar shearing machine/kN limit sound power level LWA/dB (A) 10 ~ 20103 > 20114

Table 3

Shears Hydraulic pump flow rate/(L/min) sound power level limit value LWA/dB (A) <=25 94 > 25 to 63100 > 63103

3.3.2 Shears SPL Limit

Table 4

<=10 85

> 10 ~ 2090

> 2093

Table 5

<=25 81

> 25 to 6385

> 6390

Specified in Table 6.

Table 6

<=10 101

> 10 ~ 20102

> 20103

3.4 Punching shear noise limits

3.4.1 Punching shear sound power level limits

Noise A-weighted sound power level LWA punching shear continuous idling time should not exceed 94dB (A).

3.4.2 Punching shear SPL Limit

3.5 Ironworkers noise limits

3.5.1 Ironworkers sound power level limits

During continuous idling noise A-weighted sound power level LWA shall not exceed the specified in Table 7.

Table 7

Ironworker can shear thickness/mm sound power level limit value LWA/dB (A) <=10 97 > 10 ~ 16100 > 16106

3.5.2 Ironworkers SPL Limit

Table 8

<=10 83

> 10 ~ 1686

> 1688

4 Measurement

4.1 SPL Measurement

Noise level measurement method presses shall comply GB/T 23281-2009 of.

4.2 Sound power level measurement

Sound power level measurement of the press shall comply with GB/T 23282-2009 of.

4.3 Noise Measurement Description

4.3.1 factory test only measures the noise level.

4.3.2 The new design or improve the design, technology, materials, new products after the noise level should be measured during the performance test; can then measure the noise Sound power level to the noise level of conformity assessment basis.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.

Referenced standards

How to Download GB 24389-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
5 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 24389-2009

$85.00