GB 22618-2008 is the English-translated version of 精噁唑禾草灵乳油.
GB 22618-2008 — This standard specifies the fine Oxazole diclofop EC requirements, test methods and marking, labeling, packaging, storage and transportation.
This standard applies to the fine Oxazole diclofop original drug, security agents fenchlorazole formulated with an emulsifier is dissolved in a suitable solvent from the fine Oxazole diclofop EC.
Found what you need?
Document preview — GB 22618-2008
National Standard of the People's Republic of China
- ICS
- 65.100.20
- Classification
- G 25
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Requirements
- 4.1 Sampling
- 4.2 Identification Test
- 4.3 Determination of fine azole diclofop, fenchlorazole mass fraction
- 4.4 Determination of Moisture
- 4.6 Emulsion stability test
- 4.7 Low temperature stability test
- 4.8 Thermal storage stability test
- 4.9 Product testing and acceptance
- 5 Marking, labeling, packaging, storage and transportation
Foreword
The standard Chapter 3, Chapter 5 are mandatory, the rest are recommended.
Appendix A of this standard is an informative annex.
The standard proposed by China Petroleum and Chemical Industry Association.
This standard by the National Standardization Technical Committee on Pesticides (SAC/TC133) centralized.
1 Scope
This standard specifies the fine Oxazole diclofop EC requirements, test methods and marking, labeling, packaging, storage and transportation.
This standard applies to the fine Oxazole diclofop original drug, security agents fenchlorazole formulated with an emulsifier is dissolved in a suitable solvent from the fine Oxazole diclofop EC.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 1600 Determination of Water Pesticides Determination of GB/T 1601 Pesticides pH value GB/T 1603 Determination of emulsion stability of pesticide GB/T 1604 Goods pesticide regulations for acceptance GB/T 1605-2001 Sampling Method commercial pesticides GB/T 4472 chemical product density, relative density measurement General GB 4838 EC pesticide packaging GB/T 19136 Determination of Pesticide Thermal storage stability GB/T 19137 Pesticide cryogenic stability Determination
3 Requirements
3.1 Composition and appearance. This product should be compliant oxazole diclofop fine original drug, fenchlorazole security agent and emulsifier dissolved in a suitable solvent the preparation should be stable homogeneous liquid, free from visible suspended matter and sediment.
3.2 azole fine grasses Ling EC shall comply with the requirements of Table 1.
Table 1 fine azole diclofop EC Control Project Index
project
index
6.9% 80.5g/L 100g/L
Oxazole diclofop mass fraction a /% or concentration (20 °C) / (g/L) + 0.7-0.7 0.8-0.8 6.9 8.4 + 10.4 + 1.0 to 1.0 - 100 + 80.5 + 8.0-8.0 10-10 Fenchlorazole mass fraction b /% >= declared value (accurate to 1 after the decimal point) Moisture content /% <= 1.0 pH range of 5.0 to 9.0 Emulsion stability (diluted 200 times) Qualified Low temperature stability Qualified c Thermal storage stability c qualified when a dispute occurs when the quality to fine oxazole diclofop mass fraction of arbitration.
b whether to add security agents decided by crop objects; allows the use of other security agents, the detection method and the corresponding indicators in the national pesticide requirements can be standardized technology Committee was surgery.
C When normal production, low-temperature storage stability and thermal stability test, every three months, at least once.
Test Method 4
4.1 Sampling
According to GB/T 1605-2001 5.3.2 in "liquid formulation sampled" in. Determining sample package using a random number table method, the final sample the amount of not less than 200mL.
4.2 Identification Test
HPLC --- The identification test with fine Determination oxazole diclofop content simultaneously. In the same chromatographic operation Under the conditions, the sample solution is a two peak retention time Azole grasses standard solution for the retention time of the two peaks of enantiomers relative of the difference should be less than 1.5%.
4.3 Determination of fine azole diclofop, fenchlorazole mass fraction
Determination 4.3.1 oxazole diclofop, fenchlorazole mass fraction
4.3.1.1 Method summary
Sample dissolved in mobile phase, n-hexane and isopropanol as the mobile phase, use ZORBAXSIL as filling a stainless steel column and variable wave Long UV detector, of the sample Oxazole diclofop, fenchlorazole normal phase HPLC separation and determination, external standard. also may Using capillary gas chromatography Oxazole diclofop mass fraction, chromatographic operating conditions given in Appendix A.
4.3.1.2 Reagents and solutions
Hexane. chromatography;
Isopropanol. chromatography;
Oxazole diclofop standard. a known mass fraction >=99.0%;
Fenchlorazole standard. a known mass fraction >=99.0%.
4.3.1.3 Instruments
High performance liquid chromatography. a variable wavelength UV detector;
Chromatographic data processor or chromatography workstation;
Column. 250mm × 4.6mm (i.d.) Stainless steel column, built ZORBAXSIL, 5µm particle size of the filler;
Filter. pore size of about 0.45µm;
Micro injector. 100µL;
Quantitative sample line. 10µL;
Ultrasonic cleaner.
4.3.1.4 HPLC operating conditions
Mobile phase. [Psi] (n-hexane. isopropanol) = 90.10;
Flow rate. 0.8mL/min;
Column temperature. room temperature;
Detection wavelength. 230nm;
Injection volume. 10µL;
keep time.
Oxazole diclofop 4.8min, fenchlorazole 5.5min.
The above operating conditions, the Department of typical operating parameters, according to the characteristics of different instruments and columns for a given operating parameters to make appropriate adjustments to to obtain the best results. typical Oxazole diclofop EC HPLC is shown in Figure 1.
1 --- oxazole diclofop;
2 --- fenchlorazole.
Figure 1 EC fine azole diclofop HPLC Fig.
4.3.1.5 Measurement procedure
4.3.1.5.1 Preparation of standard solution
Weigh
Oxazole diclofop standard 0.05g, fenchlorazole standard 0.03g (accurate to 0.0002g), placed in 100mL volumetric flask.
80mL mobile phase in an ultrasonic bath shaking 5min make sample dissolution, removed after cooling to room temperature, dilute to the mark with the mobile phase, Shake well.
4.3.1.5.2 Preparation of sample solution
Weigh containing
0.05g oxazole diclofop sample (accurate to 0.0002g), placed in 100mL flask, add 80mL mobile phase in the ultrasonic bath shaking 5min make sample dissolution, removed after cooling to room temperature, mobile phase and dilute to the mark, shake, filtration.
4.3.1.5.3 Determination
Under these operating conditions, after the instrument is stable, continuous injection of several doses of the standard solution until the two adjacent needles Lingfeng grass area with azole After the change of less than 1.2%, according to the solution, the sample solution, the sample solution and standard sequence of the standard solution was measured.
4.3.1.6 Calculation
The measured before and after the two-needle sample solution and two doses of the standard sample solution Oxazole diclofop (fenchlorazole) peak areas are averaged.
Specimen
(1) Calculation azole diclofop (fenchlorazole) mass fraction of 1 (%) according to formula (2) to calculate the concentration of rho1 (g/L) by the formula.
rho1 =
Where.
A1 --- the standard solution, the average oxazole diclofop (fenchlorazole) peak area;
A2 --- sample solution, the average azole diclofop (fenchlorazole) peak area;
--- Standard samples azole diclofop (fenchlorazole) mass fraction,%;
4.3.1.7 Allowable difference
Two parallel determination results relative error should not exceed 5% of the arithmetic mean as a measurement result.
4.3.2 R- enantiomer ratio of measurement
4.3.2.1 Method summary
Sample dissolved in mobile phase, n-hexane and ethanol as the mobile phase, use a stainless steel ChiralcelOK as filler chiral column and variable wave Long UV detector, of the sample Oxazole diclofop R- enantiomer normal phase high performance liquid separation and determination of the spectrum, phase separation may also be used Other chiral column or flow when the phase.
4.3.2.2 Reagents and solutions
Hexane. chromatography;
Ethanol. chromatography;
Oxazole diclofop standard. a known mass fraction >=99.0%.
4.3.2.3 Instruments
High performance liquid chromatography. a variable wavelength UV detector;
Chromatographic data processor or chromatography workstation;
Column. 250mm × 4.6mm (i.d.) Stainless steel chiral column, built ChiralcelOK, filler particle size of 10µm;
Filter. pore size of about 0.45µm;
Micro injector. 100µL;
Quantitative sample line. 20µL;
Ultrasonic cleaner.
4.3.2.4 HPLC operating conditions
Mobile phase. [Psi] (n-hexane. ethanol) = 50.50;
Flow rate. 1.3mL/min;
Column temperature. room temperature;
Detection wavelength. 280nm;
Injection volume. 20µL;
Retention time. R- enantiomer (fine azole diclofop) 8.4min, S- enantiomer 14.5min.
The above operating conditions, the Department of typical operating parameters, according to the characteristics of different instruments and columns for a given operating parameters to make appropriate adjustments to to obtain the best results. Typical fine Oxazole diclofop EC HPLC is shown in Figure 2.
1 --- R- enantiomer (fine azole diclofop);
2 --- S- enantiomer.
Figure 2 Fine oxazole diclofop EC HPLC diagram
4.3.2.5 Measurement procedure
4.3.2.5.1 Preparation of standard solution
Weigh
Oxazole diclofop standard of about 0.05g, placed in 100mL volumetric flask, dissolved in mobile phase and dilute to the mark.
4.3.2.5.2 Preparation of sample solution
Weigh about containing fine 0.05g oxazole diclofop sample, placed in 100mL volumetric flask, dissolved in mobile phase and dilute to volume, shake, filter.
4.3.2.5.3 Determination
Under these operating conditions, after the instrument is stable, continuous injection of several doses of the standard solution until the two adjacent needles Oxazole diclofop R- enantiomers, S- enantiomer relative change in peak area is less than 1.0% (both enantiomers area ratio should be 50.50, deviation does not exceed 1%. If more than 1%, calculated oxazole diclofop R- enantiomer ratios should be corrected for), then two injection needles sample solution.
4.3.2.6 Calculation
Specimen
Oxazole diclofop R- enantiomer ratio of K, according to equation (3) Calculated.
K = ARAR + AS
Where.
AR --- two needles in the sample solution, oxazole diclofop mean R- enantiomer peak area;
AS sample solution --- two needles, oxazole diclofop mean S- enantiomer peak area.
When the standard sample solution when oxazole diclofop R- enantiomer area beyond the area of the two enantiomers and the (50 ± 1)%, the sample azole Wo Grass Ling R- enantiomer ratio of K ', according to equation (4) Calculated.
K '= ARAR + AS (A'R/A'S) (4) where.
A'R --- two doses of the standard solution, oxazole diclofop mean R- enantiomer peak area;
A'S --- two doses of the standard solution, oxazole diclofop mean S- enantiomer peak area.
4.3.3 Fine oxazole diclofop mass fraction calculation
The sperm sample
2 mass fraction (%) oxazole diclofop according to equation (5) to calculate the mass concentration rho2 (g/L) according to equation (6) Calculated.
2 = 1 × K (5)
rho2 = rho1 × K (6)
When the standard sample solution oxazole diclofop R- enantiomer area beyond the area of the two enantiomers and the (50 ± 1)%, sample fine azole Diclofop mass fraction '2 (%), according to equation (7) to calculate the mass concentration rho'2 (g/L) according to equation (8) Calculated.
'2 = 1 × K' (7)
rho'2 = rho1 × K '(8)
4.4 Determination of Moisture
According to GB/T 1600 the "Karl Fischer" method.
According to GB/T 1601 carried out.
4.6 Emulsion stability test
Standard hard water sample was diluted 200-fold, according to GB/T 1603 test, the non-oil slick, no precipitation under qualified.
4.7 Low temperature stability test
According to GB/T 19137 in "homogeneous emulsion and liquid preparations" to. The bottom of the centrifuge tube educt volume of less than 0.3mL qualified.
4.8 Thermal storage stability test
According to GB/T 19136 in "liquid formulation" to. Fine grass azole azole diclofop reconciliation after the mass fraction of heat storage thermal storage mass allow the former dropped Volume fraction of 95%, emulsion stability should continue to meet the standards.
4.9 Product testing and acceptance
Shall comply with GB/T 1604's. Treatment of extreme values using the rounding value comparison method.
5 Marking, labeling, packaging, storage and transportation
5.1 oxazole diclofop fine EC marking, labeling, packaging, should meet the requirements of GB 4838.
5.2 azole fine grasses Ling EC package should be stored in well-ventilated, dry coffers.
5.3 storage, prevent moisture and sunlight, no food, seed, feed mix, avoid contact with skin, eyes, mouth and nose to prevent inhalation.
5.4 Safety. This product is a low-toxicity herbicides. Poisoning symptoms are nausea, vomiting, drowsiness occur subsequent, limb numbness, severe muscle fibrillation Move, convulsions, coma, respiratory failure. The FDA should wear protective gloves, masks and goggles, wear clean protective clothing with soap immediately after application Washed with water to avoid skin and eye contact with liquid. If swallowed, immediately induce vomiting, gastric lavage, activated charcoal and a laxative can also be used, symptomatic treatment.
5.5 Warranty. under the specified storage conditions to ensure the precision of oxazole diclofop EC, from date of manufacture for 2 years.
Appendix A
(Informative)
Oxazole diclofop content by capillary gas chromatographic method A. 1 Method summary Sample was dissolved in acetone, phthalate, dicyclohexyl phthalate as internal standard, and the use of silica capillary column HP-5 (5% phenyl methyl silicone) coated wall Flame ionization detector, the sample Oxazole diclofop and measured by gas chromatography, internal standard.
A. 2 Reagents and solutions acetone;
Oxazole diclofop standard. a known mass fraction, >=99.0%;
Internal standard. phthalate, dicyclohexyl phthalate, should not interfere with the analysis of impurities;
Internal standard solution. Weigh phthalate, dicyclohexyl phthalate 5g, placed 1000mL volumetric flask, dissolved in acetone and diluted to the mark.
A. 3 Instrument
Gas chromatograph. with a hydrogen flame ionization detector;
Chromatographic data processor or chromatography workstation;
Column. 30m × 0.32mm (i.d.) Fused silica capillary column, wall coated HP-5 (5% phenyl methyl silicone), a film thickness of 0.25µm.
A. 4 GC operating conditions Temperature (°C). Room 250 column, the gasification chamber 260, detection chamber 270;
Gas flow rate (mL/min). carrier gas (N2) 1.5, hydrogen gas 30, air 300;
Injection volume. 1.0µL;
keep time.
Oxazole diclofop about 7.8min, dicyclohexyl phthalate esters about 5.9min.
The above operating conditions, the Department of typical operating parameters, according to the characteristics of different instruments and columns for a given operating parameters to make appropriate adjustments to to obtain the best results. Typical fine Oxazole diclofop EC gas chromatography is shown in Figure A. 1.
1 --- internal standard (dicyclohexyl phthalate esters);
2 --- oxazole diclofop.
Figure A. 1 fine oxazole diclofop EC gas chromatogram
Book GB 22618-2008
A. 5 measuring step
A. 5.1 Preparation of standard solution Weigh Oxazole diclofop standard 0.07g (accurate to 0.0002g), placed in 15mL stoppered glass bottle with a pipette accurately added Internal standard solution 10mL, shake.
A. 5.2 Preparation of sample solution Weigh containing Sample of 0.07g oxazole diclofop (accurate to 0.0002g), placed in 15mL stoppered glass vial, with the A. 5.1 the same Branch pipette accurately added internal standard solution 10mL, shake.
A. 5.3 Determination Under these operating conditions, after the instrument is stable, continuous injection of several doses of the standard solution until the two adjacent needles Oxazole diclofop and the internal standard peak After the relative change in area ratio is less than 1.2%, according to the solution, the sample solution, the sample solution and standard sequence of the standard solution was measured.
A. 6 Calculation
The measured before and after the two-needle sample solution and two doses of the standard sample solution Oxazole diclofop and the internal standard peak area ratios are flat all. Specimen Oxazole diclofop mass fraction of 1 (%), according to equation (A.1) Calculated.
Where.
--- Standard samples azole diclofop mass fraction,%.
A. 7 allowable difference Two parallel determination results relative error should not exceed 5% of the arithmetic mean as a measurement result.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1600Testing method of water for pesticides
- GB/T 1601Determination method of pH value for pesticides
- GB/T 1603Determination method of emulsion stability for pesticides
- GB/T 1604Commodity pesticide regulations for acceptance
- GB/T 1605-2001Sampling method for commodity pesticides
- GB/T 4472Detemination of density and relative density for chemical products
How to Download GB 22618-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 4838-2018 — Packaging for emulsifiable concentrates of pesticides
GB/T 1600-2021 — Testing method of water for pesticides
GB/T 16006-2025 — Elimination of iodine deficiency disorders
Secure payment via Stripe
Payments accepted
GB 22618-2008
$135.00