Valid

GB 17905-2008Safety management regulation of gas-burning appliances for domestic use (English PDF)

家用燃气燃烧器具安全管理规则

Open the GB 17905-2008 preview as PDF

Preview — first pages of GB 17905-2008 (full document: 17 pages)

This is a limited preview

Buy now to download the full PDF (17 pages)

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Level / Type

National · Mandatory

Issue date

November 27, 2008

Implementation date

November 1, 2009

Scope

GB 17905-2008 is the English-translated version of 家用燃气燃烧器具安全管理规则.

GB 17905-2008 is the Chinese national standard on safety management regulation of gas-burning appliances for domestic use, in the field of construction materials and building. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 27 November 2008 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 November 2009. Classification: ICS 91.140.99, CCS Q82. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

Document preview — GB 17905-2008

National Standard of the People's Republic of China

ICS
91.140.99
Classification
Q82

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Contents

  • 1 Scope
  • 2 Normative references
  • 4.1 Producer
  • 4.2 Duties and obligations of the seller
  • 4.3 Gas supplier responsibilities and obligations Gas quality
  • 4.4 Gas appliance installers and maintenance persons
  • 5 Household appliances and fittings inspection
  • 7.3 Household Waste burning appliances sentence
  • 8 Accident
  • Appendix A
  • Appendix B
  • Appendix C
  • Appendix D

Foreword

The standard 7.3. , 8.3,8.4,

8.5 content are mandatory, the rest are recommended. This standard replaces GB 17905-2004 "domestic gas burning appliances safety management rules." This standard compared with GB 17905-2004 main changes are as follows:

--- Increasing the product suitability test specific requirements and restrictions (Chapter 5 of this standard);

--- Increased inspection requirements and product control shut-off valve; tightness LPG cylinders, angle valve, pressure regulator and rubber connecting tube And safety inspection requirements; increased product gas appliance not expressly scrap judgment age requirements (Chapter 7 of this standard);

--- Electrical products increased inspection requirements (Chapter 8 of this standard). The Standard Appendix A, Appendix B, Appendix C, Appendix D is a normative appendix. The standard proposed by the People's Republic of China Ministry of housing and Urban-Rural Development. This standard by the Ministry of Construction of housing and urban-rural town gas standard technical focal North China Municipal Engineering Design and Research Institute. This standard was drafted. North China Municipal Engineering Design Institute, Ningbo, too kitchenware Ltd., Guangzhou Devotion Domestic Boilers Manufacturing Co. The company, Guangdong Macro Gas Appliance Co., Ltd., AO Smith (China) Water Heater Co., Sakura (China) Co., Ltd., Guangdong US kitchen appliances Manufacturing Co., BSH Electrical Appliances (Jiangsu) Co., Ltd., Guangdong million and the new Electric Co., Ltd., Qingdao Economic and Technological Development Development Zone Haier Water Heater Co., national gas appliances Quality Supervision and Inspection Center. Drafters of this standard. Zhang Weihua, hair in the group, Li Zuqin, Shao Yan, Ju Ping, Huang Jin, Zheng instrument army, Liusong Hui, Zhong Song, Zheng Tao, Yang Xiaofeng, red canal. The standard alternative to the standard of previous editions are.

--- GB 17905-1999, GB 17905-2004. Domestic gas burning appliances safety management rules

1 Scope

GB 17905-2008 is the Chinese national standard on safety management regulation of gas-burning appliances for domestic use, in the field of construction materials and building. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 27 November 2008 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 November 2009. Classification: ICS 91.140.99, CCS Q82. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

Installation Qualification Requirements Training requirements for installation personnel

2 Appliance does not allow the installation locations bedroom, bathroom, room and there are flammable and explosive materials have rooms corrosive substances Indoor burning appliances row Smoke ventilation requirements Stove and other burning appliances with natural exhaust hoods, or fume hood or forced change Gas sector Air inlet area 9.5cm2/kW the above Natural gas appliance exhaust pipe connected to the exhaust smoke outdoors Large air intake area In the exhaust area Forced exhaust gas appliance exhaust or fume hood, with exhaust fan or linkage Natural supply and exhaust gas appliance connected to the exhaust to the outdoors Forced to exhaust gas appliance connected to the exhaust to the outdoors

4 airtight gas pipeline connecting gas pipeline should be no leakage

5 burning appliances should be checked using the AC fixers building electrical environmental conditions, gas appliance electrical grounding if it is safe

Note 1. The installation site, see smoke ventilation provisions of GB 50028 and CJJ12.

Note 2. LPG gas cylinders, check its installation meets the express provisions of the relevant standards.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 13611 Classification and essential property of city gas

GB 50028 City Gas Design Code CJJ12 domestic gas burning appliances installation and acceptance Safety and environmental requirements 3 burning appliances and accessories

3.1 burning appliances and accessories under normal conditions of use, consumers should not constitute a hazard to life and health, property should not make consumers A loss, should not pollute the environment.

3.2 appliances and fittings shall comply with the relevant standards of safety and environmental performance requirements.

3.3 burning appliances and accessories, security should also pay attention to the following aspects.

--- Burning appliances use gas quality should be stable, burning appliances should be properly installed and used correctly.

--- Appliance when used together with another product, possible hazards.

--- Appliance suitable for the types of consumers, especially children, the elderly and the disabled hazardous and dangerous nature.

4 responsibilities and obligations

Responsibilities and obligations

4.1 Producer

4.1.1 burning appliances and fittings producers, in burning appliances and accessories design, production and sale should comply with the relevant safety requirements, to market Products should be safe product.

4.1.2 In the sale, installation and use of the product, the producer of the product may affect the safe behavior should take protective measures, through the production The key parts of the product will be sealed, playing wax or unconventional bolt connection, in order to ensure safety during the performance is not compromised.

4.1.3 When burning appliances and fittings are unsafe product, resulting in bodily injury, property damage when producers should assume responsibility.

4.1.4 Producers obligation to participate in safety campaign products on the market when, in particular, should provide information on the risk of burning appliances and accessories, so that Consumers understand the product during installation and use is possible to foresee the danger.

4.2 Duties and obligations of the seller

4.2.1 The seller should bear the responsibility and obligation to sell the security and safety of burning appliances in the accessories market.

4.2.2 Sales of imported burning appliances and accessories sellers, responsible for the safety of burning appliances and accessories.

4.2.3 sellers in the sales process, should take measures to ensure product safety. The seller is obliged to inform consumers in the installation and make What measures should be taken to burning appliances and accessories used, if necessary in conjunction with the producers for training, surveys and interviews together; product tracking inspection Test test; the complaints of product safety.

4.2.4 The seller shall provide relevant information to consumers, in particular, to provide information on the risk of burning appliances and accessories, so that consumers understand the product Possible foreseeable risk during installation and use.

4.3 Gas supplier responsibilities and obligations Gas quality

4.3.1 Gas suppliers provided shall comply with the relevant regulations.

4.3.2 gas supplier is obliged knowledge of the safe use of gas to consumer information. Responsibilities and obligations

4.4 Gas appliance installers and maintenance persons

4.4.1 gas appliance installation unit, maintenance unit must be qualified.

4.4.2 gas appliance installers, maintenance staff must be trained and gain accreditation.

4.4.3 gas appliance installation, maintenance must comply with the relevant standards.

4.4.4 installation and maintenance staff to deal with the installation and maintenance of gas appliance responsible for the quality.

4.4.5 installer, service consumers are obliged to secure publicity. Responsibilities and obligations of consumers 4.5

4.5.1 Consumers buy gas appliance, gas appliance should carefully read the product installation manual, in accordance with the relevant provisions of the correct specification use.

4.5.2 Consumers should provide the installation site meets the installation requirements to ensure that the normal use of the gas appliance.

4.5.3 Consumer product specification should be prescribed regularly for regular gas appliance, simple, clean and easy maintenance.

4.5.4 Consumers found burning appliances use when abnormal, should immediately stop using, and timely contact with the seller or producer, acquired skills Surgery support and protection.

4.5.5 Consumers are responsible for installation and maintenance work carried out by mating.

4.5.6 In the event of an accident, consumers should protect the scene and notify the authorities.

5 Household appliances and fittings inspection

5.1 burning appliances and accessories type test, the relevant standards shall be burning appliances and fittings, inspection units should be authorized by the State Inspection Appliance mechanism.

5.2 is a mandatory product management appliances and fittings, production license and product market supervision and inspection work should be national product quality supervision Governor department were related regulations.

5.3 gas appliance manufacturers and sellers to deal with the use of local artificial gas gas appliance, the gas carried suitability test, compatibility test should only burn Inspection of a combustion conditions.

6 household gas appliance installation and maintenance of regulatory

Regulated gas appliance installation and maintenance shall comply with the relevant state regulations. 7 household gas appliance use, maintenance, repair and scrap judgment

7.1 gas appliance use, maintenance, repairs shall comply with the relevant state regulations.

7.2 gas appliance manufacturers and maintenance organizations contracted gas supply businesses, users should receive commission for gas appliance safety checks and safety Publicity, and check register. Gas appliance in question shall submit written comments and record maintenance. Check the following. Function

a) the operation of each gas appliance parts, gas appliance service life;

b) When the burner flame stability;

c) the controller function, normally closed valve function and fail-safe shut down function;

d) flue sealing and pumping power, gas appliance connected airtight tube;

e) to the exhaust flue and clogging; to the exhaust system is smooth;

f) AC safety inspections and gas appliance installation environment, check the ground conditions;

g) LPG cylinders, angle valve, pressure regulator, rubber connecting pipe air tightness and security;

7.3 Household Waste burning appliances sentence

7.3.1 burning appliances sold from the date.

a) the use of artificial gas instantaneous water heaters, storage water heater and heating of the water heater should be sentenced to waste years 6 years;

b) the use of liquefied petroleum gas and natural gas instantaneous water heaters and storage water heater and heating water heaters waste years of sentence is 8 years;

c) determination of waste gas cooker age is 8 years;

d) burning appliances sentenced waste years have stated, their products should be subject to the express, but not less than the prescribed number of years or more;

e) other than those specified above burning appliances scrap judgment age should be 10 years.

7.3.2 gas water heaters and other gas appliance, one of the following fault still occurs after overhaul, if not optimal waste years sentence, should be sentenced to waste.

a) serious deterioration of the combustion conditions, the content of carbon monoxide gas in the rear access still can not reach the relevant standards;

b) a combustion chamber, a heat exchanger or severe burning flame spills;

c) after the repair is still leaking, leaks or insulation breakdown leakage.

8 Accident

8.1 Appliance Accident shall be the relevant provisions of the State.

8.2 The first witness should protect the scene and immediately notify the authorities survey the scene, sealed gas appliance.

8.3 Major Accident accordance with the relevant provisions; by the accident investigation team composed of relevant departments investigate and deal with.

8.4 Processing Appliance accident, should be associated with the gas appliance regulations, standards, accident made four technical appraisal certificate.

--- Fixers safety inspection site (see Appendix A);

--- Burning appliances use and maintenance (see Appendix B);

--- Gas supply quality (see Appendix C);

--- Quality Appliance (see Appendix D).

8.5 Appliance inspection accident after accident burning appliances should remove foreign bodies, according to the different types of accidents were detected.

a) Carbon monoxide poisoning (following performance criteria should be consistent with the express provisions of the relevant product).

--- Appliance air tightness;

--- Flame stability;

--- Flue gas carbon monoxide.

b) a gas leak caused the accident.

Appendix A

(Normative) Gas appliance installation site safety inspection Table A. 1 fixers content site safety inspections Product Name Model production units production date No. Item Content Conclusion

Appendix B

(Normative) Use and maintenance of burning appliances B. 1 prescribed burning appliances product instructions, check the user correct the situation burning appliances use. B.

2 Press the gas appliance to the instructions and check the gas appliance maintenance situation. B.

3 Check the qualifications of the maintenance staff.

Appendix C

(Normative) Gas supply quality C. 1 gas type and quality of Table C. 1. Table C. 1 gas type and quality Gas project category Wobbe number W burning potential CP Conclusion Artificial gas 3R, 4R, 5R, 6R, 7R Gas 3T, 4T, 6T, 10T, 12T LPG 19Y, 20Y, 22Y

Note 1. Gas mass See GB 50028 and GB/T 13611.

Note 2. Gas special provisions in accordance with local gas company to check temperament. C. 2 gas supply pressure Table C. 2. Table C. 2 gas supply pressure Item Rated Pressure (Pn)/kPa fluctuation Conclusion Artificial gas 1.0 (0.75 ~ 1.5) Pn Gas 3T, 4T, 6T 1.0 (0.75 ~ 1.5) Pn 10T, 12T

2.0 Bottled liquefied 2.8 ± 0.5kPa LPG 5.0 ± 1kPa Liquefied petroleum gas pipeline pressure (0.75 ~ 1.5) Pn.

Note. LPG gas cylinders, you should check the regulator and hose and other accessories are secure compliance with the express provisions of the relevant standards.

Appendix D

(Normative) Appliance Quality Appliance quality requirements in Table D.

1 Table D. 1 gas appliance quality requirements Product Name Model production units production date No. Test Item Requirement temperament test conditions Conclusion

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

How to Buy GB 17905-2008

  1. 1Add to cart. Click the "Buy GB 17905-2008" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 17905-2008

$140.00

$120.00for partners