GB 10963.2-2008Electrical accessories. Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-breakers for AC and DC operation (English PDF)
家用及类似场所用过电流保护断路器 第2部分:用于交流和直流的断路器
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for GB 10963.2-2008 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
November 19, 2020
Implementation date
June 1, 2021
Scope
GB 10963.2-2008 is the English-translated version of 家用及类似场所用过电流保护断路器 第2部分:用于交流和直流的断路器.
GB 10963.2-2008 — Except for the following, Chapter 1 of GB/T 10963.1-2020 is applicable. Add at the end of paragraph 1.
This part of GB/T 10963 specifies supplementary technical requirements applicable to single-pole and two-pole circuit breakers operating in DC circuits. single the rated DC voltage of the pole circuit breaker does not exceed 220V, the two poles does not exceed 440V, the rated current does not exceed 125A, and the rated DC short-circuit capacity does not exceed More than 10000A.
Note. This section applies to circuit breakers that can make and break AC current and can make and break DC current. Delete paragraphs 11 and 12.
Found what you need?
Document preview — GB 10963.2-2008
National Standard of the People's Republic of China
- ICS
- 29.120.50
- Classification
- K 31
- Replacing
- GB/T 10963.2-2008
Issued by: State Administration for Market Regulation
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Category
- 5 Breaker characteristics
- 6 Logo and other product information
- 7 Standard operating conditions for use
- 8 Structure and action requirements
- 9 Test
- Appendix
- Appendix C (Normative appendix) Test procedure and number of samples
Foreword
GB/T 10963 "Overcurrent protective circuit breakers for electrical accessories household and similar places" is divided into the following three parts.
---Part 1: Circuit breakers for AC;
---Part 2: Circuit breakers for AC and DC;
---Part 3: Circuit breakers for DC.
This part is Part 2 of GB/T 10963.
This section was drafted in accordance with the rules given in GB/T 1.1-2009.
This part replaces GB/T 10963.2-2008 "Overcurrent protective circuit breakers for household and similar places Part 2: Used for AC and Compared with GB/T 10963.2-2008, the main technical changes are as follows.
--- Table 1 adds the circuit type of DC circuit breaker power supply;
---9.2 The ripple or instantaneous value requirements of DC voltage (current) are added;
--- In 9.10.3, for circuit breakers of different trip types, the upper limit value passes current to each pole, and the lower limit value passes current to all poles in series;
---Added 9.12.11.4.4 "Single-pole rated making and breaking capacity performance of two-pole circuit breakers";
---In appendix C, 9.15 abnormal heat resistance and flame resistance test are independent of procedure A2, according to the latest 9.7 update test procedure B, add C3 in the small DC current test of 150A and below, the single-pole rated making and breaking capacity performance of the E3 two-pole circuit breaker is increased.
This part uses the redrafting law to amend and adopt IEC 60898-2:2016 "Electrical accessories for household and similar places using overcurrent protection Circuit Breaker Part 2: Circuit Breakers for AC and DC".
The technical differences between this part and IEC 60898-2:2016 and the reasons are as follows.
---In order to be more in line with the meaning of the original text and consistent with other parts of this series, in the test a row of Table 7, "t>=1h" and "t>=2h" Amend to "t<=1h" and "t<=2h";
---In order to verify the safety of the product more comprehensively, in "9.11.2", "9.12.11.2.3", "9.12.11.2.4", "9.12.11.3", "9.12.11.4.2" and in "9.12.11.4.3", the test requirements for wiring in the opposite direction are added for circuit breakers without specified polarity;
---9.12.11.2.4 In order to avoid ambiguity during the test, add "each protection pole of the circuit breaker should be connected to the wiring mode shown in Figure 3 Test in the circuit. Adjust the time constant to a value corresponding to the specified time constant".
This part was proposed by China Electrical Equipment Industry Association.
This part is under the jurisdiction of the National Low Voltage Apparatus Standardization Technical Committee (SAC/TC189).
Drafting organizations of this section. Shanghai Electric Research Institute, Shanghai Liangxin Electric Co., Ltd., Zhejiang Chint Electric Co., Ltd., Suzhou Future Electric Co., Ltd., Shanghai Chaoan Electric Co., Ltd., Beijing ABB Low Voltage Electric Co., Ltd., Meigao Electric Technology Co., Ltd.
Company, Shanghai Noak Electric Co., Ltd., Zhejiang People's Electric Co., Ltd., Bull Group Co., Ltd.
1 Scope
Except for the following, Chapter 1 of GB/T 10963.1-2020 is applicable.
Add at the end of paragraph 1.
This part of GB/T 10963 specifies supplementary technical requirements applicable to single-pole and two-pole circuit breakers operating in DC circuits. single the rated DC voltage of the pole circuit breaker does not exceed 220V, the two poles does not exceed 440V, the rated current does not exceed 125A, and the rated DC short-circuit capacity does not exceed More than 10000A.
Note. This section applies to circuit breakers that can make and break AC current and can make and break DC current.
Delete paragraphs 11 and 12.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated references, the latest version (including all amendments) applies to this document.
Chapter 2 of GB/T 10963.1-2020 is applicable, adding the following content.
GB/T 10963.1-2020 Electrical accessories for household and similar places with overcurrent protective circuit breakers Part 1: Used for AC Circuit breaker (IEC 60898-1:2015, IDT)
3 Terms and definitions
Chapter 3 of GB/T 10963.1-2020 is applicable, but amended as follows.
increase.
3.5.10.3
Timeconstant
Expect the time when the DC current rises to 0.63 times the maximum peak current.
Note. T=L/R, the unit is milliseconds (ms).
4 Categories
Chapter 4 of GB/T 10963.1-2020 is applicable, but amended as follows.
4.2 According to the number of poles
replace.
---Single pole circuit breaker;
---Two pole circuit breaker with two protection poles.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
Referenced standards
Normative references
IEC 60898
Cited by
- GB/T 14048.2-2020Low-voltage switchgear and controlgear—Part 2: Circuit-breakers
- GB/T 19954.1-2016Electromagnetic compatibility - Product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use - Part 1: Emissions
- GB/Z 22203-2016Reliability test method of circuit-breakers for overcurrent protection for household and similar installation
- GB/Z 32513-2016General rules of reliability for low voltage apparatus
- SN/T 1431.2-2011Rules for the inspection of low-voltage electrical apparatus for import and export. Part 2: Circuit-breakers for overcurrent protection for household and similar installations
How to Download GB 10963.2-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10963.1-2020 — Electrical accessories. Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a. c. operation
GB 10963.1-2005 — Electrical accessories. Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a. c. operation
GB 11118-2026 — Hydraulic fluids (L-HL, L-HM, L-HV, L-HS and L-HG type)
Secure payment via Stripe
Payments accepted
GB 10963.2-2008
$115.00