GA 1210-2014Security technical requirements for building intercom systems (English PDF)
This is a limited preview
Buy now to download the full PDF (29 pages)
Need quotation for your management?
Get a formal quotation for GA 1210-2014 in 30 minutes.
Issued by
Ministry of Public Security of the People's Republic of China 3. No action is required - Full-copy of this sta
Level / Type
National · Mandatory
Issue date
December 23, 2014
Implementation date
January 1, 2015
Scope
GA 1210-2014 (Security technical requirements for building intercom systems) is available as an English-translated PDF.
GA 1210-2014 — This standard specifies the functions, performance requirements and test methods of the building intercom system associated with the security. This standard applies to the building intercom system used in residential and commercial buildings (hereinafter referred to as "system").
Found what you need?
Document preview — GA 1210-2014
National Standard of the People's Republic of China
- ICS
- 13.310
- Classification
- A 91
Issued by: Ministry of Public Security of the People's Republic of China 3. No action is required - Full-copy of this sta
Contents
- Foreword...3
- 1 Scope...4
- 2 Normative references...4
- 3 Terms, definitions and abbreviations...5
- 4 System components...7
- 5 Functional requirements...8
- 6 Performance requirements...10
- 7 Test method...14
- Appendix A (Normative) Alarm control and management requirements...17
- Appendix B (Normative) Audio characteristic test...21
- Appendix C (Normative) Video characteristics test...29
Foreword
All the technical content of this standard is mandatory.
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the functions, performance requirements and test
methods of the building intercom system associated with the security.
This standard applies to the building intercom system used in residential and
commercial buildings (hereinafter referred to as "system").
2 Normative references
The following documents are essential to the application of this document. For
the dated documents, only the versions with the dates indicated are applicable
to this document; for the undated documents, only the latest version (including
all the amendments) are applicable to this Standard.
GB 4208 Degrees of protection provided by enclosure (IP code)
GB 12663-2001 General specifications for burglar-alarm control units
GB/T 16796-2009 Safety requirements and test methods for security alarm
equipment
GB/T 30148-2013 Security alarm equipment - EMC immunity requirements
and test methods
GB/T 31132-2014 Intrusion alarm systems - Technical requirements for
interconnection of equipment using radio frequency
ITU-TP.50 Artificial voice
ITU-TP.51-1996 Artificial mouth
ITU-TP.57-2011 Artificial ear
ITU-TP.501 Test signal for telephone measurement
3 Terms, definitions and abbreviations
3.1 Terms and definitions
The following terms and definitions apply to this document.
3.1.1
Building intercom system; BIS
It refers to the electronic system which is used in the residential and
commercial buildings, has such functions as selective call, intercom, visual
(if any) and so on, AND is able to control the unlocking.
3.1.2
Visitor call unit; VCU
It refers to the device which is installed at the entrance of the controlled
building, can choose to call the user receiver and management unit, AND is
able to realize intercom, camera (if any) and unlocking control.
3.1.3
User receiver unit; URU
It refers to the device which can be selectively called by the visitor call unit
or the management unit, achieve intercom and visual (if any), AND is able to
control the unlocking of the visitor call unit.
3.1.4
Management unit; MU
It refers to the device that is used by an administrator to realize two-way
selective call and intercom with the visitor call unit and user receiver unit
AND it is able to control the unlocking of the visitor call unit.
3.1.5
Special auxiliary device
It refers to a dedicated device for assisting in the realization of basic
functions in a system, such as the device for implementing system
communication, remote control, and interface integration with a third-party
device.
It refers to the gain of the sound pressure of the ear reference point at the
receiving end as relative to the excitation sound pressure of the mouth
reference point at the sending end, in dB, which is a function of frequency.
3.1.13
Acoustic delay
It refers to the one-way delay time required by the voice signal input into the
mouth reference point at the sending end through each component of the
system to the output from the ear reference point at the receiving end.
3.1.14
Idle channel noise
It refers to the noise as measured from the receiving end of the interphone
when there is no test signal transmission after the channel is established, in
dB (A).
3.1.15
Loudness rating guard-ring position; LRGP
It refers to, when measuring the loudness rating of the system, the relative
position of the management unit or user receiver handle to the artificial
mouth.
3.2 Abbreviations
The following abbreviations apply to this document.
EUT. Equipment under test
4 System components
The basic composition of the building intercom system shall include the visitor
call unit in wired connection, user receiver unit, power supply, and the possible
special auxiliary device AND/OR common auxiliary device, AND it may be
equipped with the management unit as required. The composition diagram of
the system is as shown in Figure 1.
unlocking. AND the user shall be able to confirm and manually control the
unlocking through the user receiver unit after receiving the visitor calls. The
system shall have an unlocking signal output interface.
Note. The unlocking signal output interface is usually provided by the visitor call
unit.
5.1.5 Night operation
Visitor call unit shall be able to provide night key backlight and camera auto
lighting function to facilitate the night operation of user.
5.1.6 Operation instructions
The system shall have the operation information prompt function. The visitor
call unit shall have a clear call operation indication or identification, AND shall
provide audible and/or visual prompts during operation and unlocking.
5.2 System function requirements of management unit configuration
The system configuring the management unit shall, in addition to the
requirements of 5.1, also comply with the following requirements.
a) The management unit shall be able to selectively call the user receiver
unit, the visitor call unit and the user receiver unit shall be able to call the
management unit, all calls shall have the corresponding call and answer
prompt signal, AND the prompt signal can be auditory and/or visual;
b) The management unit shall have an intercom function with the visitor call
unit and the user receiver unit;
c) The management unit shall have an electronic control unlocking function,
AND the administrators shall be able to confirm and manually control the
unlocking after receiving the visitor calls.
5.3 Overhearing prevention
When a two-way call is established between each management unit, visitor call
unit, or user receiver unit in the system, the call voice shall not be overheard by
other user receiver units or management units in the system.
5.4 Door open overtime alarm
When the open time of the electronically controlled door exceeds the system
default value, it shall immediately issue an audible alarm prompt. For the
system configured with management unit, the alarm information shall be sent
to the management unit in real time.
b) User receiver unit using the handle calling AND the management unit side.
shall not be greater than 48 dB(A).
6.1.5 Ringing sound pressure
The ringing sound pressure shall be not less than 73 dB(A) AND not more than
106 dB(A).
6.2 Video characteristics
6.2.1 Image resolution
Image resolution shall meet the following requirements.
a) Black and white image resolution. shall not be less than 250 TVL;
b) Color image resolution. shal...
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 29 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 12663-2001Intrusion and hold-up alarm systems - Control and indicating equipment
- GB/T 30148-2013Security alarm equipment -- EMC immunity requirements and test methods
GB 4208 · GB/T 16796-2009 · GB/T 31132-2014
How to Download GA 1210-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 30148-2013 — Security alarm equipment -- EMC immunity requirements and test methods
GA 36-2018 — License plates of motor vehicles of the P. R. China
GA 1258-2015 — Requirements for number and packing-mark of civilian firearms
Secure payment via Stripe
Payments accepted
GA 1210-2014