Scope

CJ/T 409-2012 (Technical Requirement of Fiber Glass Reinforced Plastic Septic Tank) is available as an English-translated PDF.

CJ/T 409-2012 — This Standard specifies the raw material, model and structure, requirements, test methods, inspection rules, label, package, transportation and storage of fiber-glass reinforced plastic septic tank (herein after refers to "septic tank").

This Standard is applicable to the septic tank with raw materials of glass fiber and unsaturated polyester resin.

Found what you need?

Document preview — CJ/T 409-2012

National Standard of the People's Republic of China

ICS
91.140
Classification
Q 86

Issued by: Ministry of Housing and Urban-Rural Development of the People's Republic of China

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Normative References...4
  • 3 Raw Materials...5
  • 4 Model and Structure...5
  • 5 Requirements...6
  • 6 Test Methods...7
  • 7 Inspection Rules...8
  • 8 Label, Package, Transportation and Storage...9

Foreword

This Standard was drafted as per the rules specified in GB/T 1.1-2009.

This Standard was proposed by Standard and Quantity Institute, Ministry of Housing

and Urban-Rural Development.

This Standard shall be under the jurisdiction of National Technical Committee for

Standardization of Building Water Supply and Drainage - Ministry of Housing

and Urban-Rural Development.

Drafting organizations of this Standard. Henan Yeajar Environmental Protection Co.,

Ltd., and Beijing Sino-Japanese Chengqimei Environment Technology

Development Co., Ltd.

Participating drafting organizations of this Standard. Hebei (Yijia) Jiewei Environ-Tech

Co., Ltd., Shaanxi Yijia Environ-Tech Co., Ltd., Fuzhou Yilin Environment Technology

Co., Ltd., Hangzhou Jiaqing Environment Technology Co., Ltd., Wuhan Green Tide

Environ-Tech Co., Ltd., Guangzhou Kangwei Envrion-Tech Co., Ltd., Ganshu Yijia

Environmental Engineering Co., Ltd., Guangxi Nanning Guixiang Environmental

Science and Technology Co., Ltd., Hunan Timelion Composite Materials Co., Ltd.,

Zhangjiagang Wilson Environmental Protection Equipment Co., Ltd., and Shanghai

Green Tide Environmental Protection Co., Ltd.

Chief drafting staffs of this Standard. Xu Shaorong, Liu Hongqiang, Yang Qingxue, Li

Jianzhi, Liang Yanqiang, Hao Jihu, Lin Yongfu, Weng Aifu, Yu Jianjun, Liu Xianqi,

Shen Ling, Huang Yuehou, Zeng Jianxiang, Li Wenqing, Liang Xiaohong, Xing Tao, Li

Rongxiang, Huang Jianfen, and Han Zhihe.

Technical Requirement of

Fiber-Glass Reinforced Plastic Septic Tank

1 Scope

This Standard specifies the raw material, model and structure, requirements, test

methods, inspection rules, label, package, transportation and storage of fiber-glass

reinforced plastic septic tank (herein after refers to "septic tank").

This Standard is applicable to the septic tank with raw materials of glass fiber and

unsaturated polyester resin.

2 Normative References

The following documents are essential to the application of this document. For the

dated documents, only the versions with the dates indicated are applicable to this

document; for the undated documents, only the latest version (including all the

amendments) are applicable to this Standard.

GB/T 1447 Test Method for Tensile Properties of Glass Fiber - Reinforced Plastics

GB/T 1449 Test Method for Flexural Properties of Glass Fiber - Reinforced

Plastics

GB/T 1462 Test Methods for Water Absorption of Fiber Reinforced Plastics

GB/T 2575 Test Method for Resistance of Glass Fiber Reinforced Plastics to

Water

GB/T 3854 Test Method for Hardness of Reinforced Plastics By Means of Barcol

Impresser

GB/T 8237 Liquid Unsaturated Polyester Resin for Fiber Reinforced Plastics

GB/T 18369 Glass Fiber Roving

GB/T 18370 Glass Fibre Woven Roving

GB/T 21238 Glass Fiber Reinforced Plastics Mortar Pipes

6.6 Water absorption rate

It shall be measured as per GB/T 1462.

6.7 Water resistance

It shall be measured as per GB/T 2575.

6.8 Impact strength

In the place over the central position of the septic tank (avoid the cleaning hole), use a

2000g steel ball to conduct free fall from the height 2m; measure at the place where

the steel ball impacts.

6.9 Leakage test

Fix the septic tank in backfill or other modes; seal the inlet and outlet, fill the tank with

water thoroughly; stand for 24h to observe; there shall be no leakage or obvious

deformation phenomena.

6.10 Initial ring stiffness

It shall be measured as per GB/T 21238.

7 Inspection Rules

Inspection is divided into exit-factory inspection and type inspection.

7.1 Exit-factory inspection

7.1.1 Inspection items

Before each septic tank leaves the factory, it shall conduct inspection items in 5.1, 5.2

and 5.3.6.

7.1.2 Judgment rules

If each item in exit-factory inspection conforms to the requirements, then the product

shall be judged as qualified. If there are disqualified items, the product shall be

repaired once, then re-inspect; if it is still disqualified after repairing, then judge this

batch of products as disqualified.

7.2 Type Inspection

7.2.1 Type inspection conditions

Type inspection includes all items in Chapter 5. When one of the following conditions

occurs, the type inspection shall be conducted.

a) When determining the product model and put into production;

b) When raw materials and formulation have significant changes, which may affect

the product performance;

c) Conduct the inspection every three years for normal production;

d) Restore production when shutdown for more than half a year.

7.2.2 Sampling

Conduct sampling from the qualified products in exit-factory inspection.

7.2.3 Judgment

After inspection, if there are disqualified items, allow for double sampling and

re-inspecting. After that, if there are still disqualified items, then such batch of product

shall be judged as disqualified.

8 Label, Package, Transportation and Storage

8.1 Label

After test is qualified, the products shall have the following labels.

a) Trademark;

b) Serial number;

c) Product name;

d) Specification, model;

e) Direction marks for the inlet and outlet water pipe;

f) Manufacturer name;

g) Contact phone;

h) Production reference standards.

8.2 Package

Generally, the septic tank shall not be packed.

When leaving the factory, the septic tank shall have qualification certificate, and

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

Referenced standards

How to Download CJ/T 409-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

CJ/T 409-2012

$125.00