YY/T 1944-2024Particular specification for medical X-ray high voltage generator (English PDF)

医用X射线高压发生器专用技术条件

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 1944-2024 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

September 29, 2024

Implementation date

April 15, 2026

Scope

YY/T 1944-2024 is the English-translated version of 医用X射线高压发生器专用技术条件.

YY/T 1944-2024 is the Chinese standard "Particular specification for medical X-ray high voltage generator". Its scope clause reads: This document specifies the requirements for medical X-ray high voltage generators (hereinafter referred to as high voltage generators) and describes the corresponding test methods.

This document applies to high voltage generators for medical X-ray generating devices, including but not limited to high voltage generators integrated with X-ray tubes. Life tool. Its clauses include terms and definitions.

Found what you need?

Document preview — YY/T 1944-2024

National Standard of the People's Republic of China

ICS
11.040.50
Classification
C43

Issued by: National Medical Products Administration

Contents

  • Preface
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Categories
  • 5 Requirement
  • 5.1 Working conditions
  • 5.2 Product performance
  • 5.3 Limitation of voltage, current or energy
  • 5.4 Leakage Current
  • 5.5 Dielectric strength
  • 5.6 Limitation of radiated output
  • 5.7 Safety measures to prevent excessive radiation output
  • 5.8 Loading Factor Range
  • 5.9 Electromagnetic compatibility
  • 5.10 Environmental testing
  • 5.11 Security
  • 6 Test methods
  • 6.1 Working conditions
  • 6.2 Test methods
  • 6.3 Limitation of voltage, current or energy
  • 6.4 Leakage Current
  • 6.5 Dielectric strength
  • 6.6 Limitation of radiated output
  • 6.7 Safety measures against excessive radiation output
  • 6.8 Loading Factor Range
  • 6.9 Electromagnetic compatibility
  • 6.10 Environmental test
  • 6.11 Security

1 Scope

This document specifies the requirements for medical X-ray high voltage generators (hereinafter referred to as high voltage generators) and describes the corresponding test methods.

This document applies to high voltage generators for medical X-ray generating devices, including but not limited to high voltage generators integrated with X-ray tubes.

Life tool.

2 Normative references

The contents of the following documents constitute essential clauses of this document through normative references in this document.

For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to

This document.

GB 9706.1 Medical electrical equipment Part 1.General requirements for basic safety and essential performance

GB 9706.103 Medical electrical equipment Part 1-3.General requirements for basic safety and essential performance Collateral standard. Diagnostic X

Radiation protection of radiation equipment

YY/T 0291 Environmental requirements and test methods for medical X-ray equipment

YY 9706.102 Medical electrical equipment Part 1-2.General requirements for basic safety and essential performance Collateral standard. Electromagnetic compatibility

Requirements and tests definedterms)

3 Terms and definitions

The terms and definitions defined in GB 9706.1, GB 9706.103, YY 9706.102, IEC TR60788 and the following apply to this document.

Note. According to the definition in GB 9706.103, unless otherwise specified, in this special standard.

The X-ray tube voltage value refers to the peak voltage, ignoring instantaneous changes;

The X-ray tube current value refers to the average value.

3.1 Electric power

During the specified loading time, the power applied by the high voltage generator to the X-ray tube is equal to the coefficient of the X-ray tube voltage waveform, the X-ray

The product of the line tube voltage and the X-ray tube current.

P=fUI

Where.

P ---Electric power;

f --- coefficient dependent on the X-ray tube voltage waveform, selected as follows.

a) Six-peak high voltage generator f=0.95, or b) twelve-peak high voltage generator or constant voltage high voltage generator f=1.00, or c) For other X-ray high voltage generators, select the most suitable value according to the waveform of the X-ray tube voltage and give the selected value.

illustrate;

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 1944-2024

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1944-2024

$240.00