YY/T 1772-2021Implants for surgery-Standard test method for conducting and evaluating galvanic corrosion tests in electrolytes (English PDF)
外科植入物 电解液中电偶腐蚀试验方法
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1772-2021 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
March 9, 2021
Implementation date
April 1, 2022
Scope
YY/T 1772-2021 is the English-translated version of 外科植入物 电解液中电偶腐蚀试验方法.
YY/T 1772-2021 is the Chinese pharmaceutical industry standard that gives the test method for galvanic corrosion of surgical implants, the corrosion that appears where two different metals are in electrical contact in the body.
It covers the selection and preparation of the specimens, the test environment and the electrolyte, the way the couple is exposed and the characterization of the result, so that the corrosion behaviour of such a couple can be described and compared.
It applies to two or more different metals used together as a surgical implant or as parts of one. Issued on 9 March 2021, it has applied since 1 April 2022.
Found what you need?
Document preview — YY/T 1772-2021
National Standard of the People's Republic of China
- Classification
- C 35
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Significance and application
- 4 Instrument
- 5 Test sample
- 6 Test environment
- 7 Test Step
- 8 Evaluation of the sample
- 9 Report
- Appendix A (informative appendix) Typical test electrolytic cell
- Appendix B (Informative Appendix) Basic Principle
- Reference
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard provides the galvanic corrosion test and evaluation methods for surgical implants, covering sample selection, sample preparation, test environment, and exposure methods.
Formula and characterization of the evaluation method of the test results of the corrosion behavior of the galvanic couple in the electrolyte.
This standard is applicable to characterize the electrical contact state of two or more different metals applied to the human body as surgical implants or parts thereof Corrosion behavior.
This standard does not apply to the evaluation of other forms of corrosion and degradation of surgical implants. This standard also does not apply to the evaluation surface Change of state.
Note 1.The types of devices that may need to be evaluated include overlapping brackets of different alloys, combinations of brackets and bracket markers, and one or more screws in bone plates and screws.
The nail and the rest of the device belong to a combination of different alloys, a multi-component structure made of two or more alloys. For those partially implanted but Devices that have long-term contact with the human body (such as external fixation devices) can also be evaluated using this standard.
Note 2.The effects of other forms of corrosion and degradation of equipment include but are not limited to the following conditions. such as fretting corrosion, crevice corrosion, and any galvanic corrosion on stress The influence of corrosion and corrosion fatigue, etc.
Note 3.The surface state changes include but are not limited to the following conditions. such as (may be caused by the implantation process) scratches or (during the manufacturing process) welding effects.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated reference documents, the latest version (including all amendments) is applicable to this document.
GB/T 6682 Analytical laboratory water specifications and test methods
YY/T 0695-2008 Standard Test Method for Cyclic Potential Polarization of Corrosion Sensitivity of Small Implanted Devices
YY/T 1552 Surgical Implant Evaluation Method of Open Circuit Potential Measurement for the Long-term Corrosion Behavior of Metal Implant Materials and Medical Devices
3 Significance and application
3.1 Implantable medical devices can be made of different metals, and can also be in electrical contact with different metals, causing galvanic corrosion.
This can lead to the release of corrosion products, which can trigger harmful biological reactions or sacrifice the structural integrity of the device. So measure these plantable The galvanic corrosion susceptibility of the imported device is very important.
3.2 The use of this test method is to provide information on the galvanic components that corrode when two different metals are in contact with each other. Different gold in contact with each other The genus can be on the same implant device, or it can be an independent implant device component.
3.3 This test method is designed to adapt to various device shapes and sizes by using a variety of fixtures.
3.4 This standard is a test method for galvanic corrosion test under simulated physiological environment. Strictly following this test method helps to avoid this Some inherent confusion in class testing.
4 Instruments
4.1 Potentiostat
4.1.1 A high-impedance potentiostat that can be connected to a zero-resistance ammeter (ZRA).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 6682Water for analytical laboratory use - Specification and test methods
- YY/T 0695-2008Standard test method for conducting cyclic potentiodynamic polarization measurements to determine the corrosion susceptibility of small implant devices
- YY/T 1552Implants for surgery-Measurements of open-circuit potential to assess corrosion behaviour of metallic implantable materials and medical devices over extended time periods
Similar standards
How to Download YY/T 1772-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
YY/T 0695-2008 — Standard test method for conducting cyclic potentiodynamic polarization measurements to determine the corrosion susceptibility of small implant devices
YY/T 1552-2017 — Implants for surgery-Measurements of open-circuit potential to assess corrosion behaviour of metallic implantable materials and medical devices over extended time periods
Secure payment via Stripe
Payments accepted
YY/T 1772-2021
$180.00