Valid

YY/T 1717-2020Nucleic acid extraction kit(magnetic beads method) (English PDF)

核酸提取试剂盒(磁珠法)

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 1717-2020 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

March 31, 2020

Implementation date

April 1, 2021

Scope

YY/T 1717-2020 is the English-translated version of 核酸提取试剂盒(磁珠法).

YY/T 1717-2020 is the Chinese pharmaceutical industry standard for nucleic acid extraction kits based on magnetic beads.

It gives the terms and definitions, the classification, the technical requirements, the test methods, the identification, labels and instruction manual, and the rules for packaging, transport and storage, covering the yield and purity of the nucleic acid recovered, the carry-over between samples, the absence of inhibitors in the eluate, the repeatability and the stability.

It applies to kits that extract nucleic acid from serum, plasma, whole blood, cerebrospinal fluid, milk, saliva, urine, sputum, swabs, tissue and paraffin-embedded material. It was issued on 31 March 2020 and has applied since 1 April 2021.

Found what you need?

Document preview — YY/T 1717-2020

National Standard of the People's Republic of China

ICS
11.040
Classification
C 44

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Categories
  • 5 Technical requirements
  • 6 Test method
  • 7 Logo, label and instruction manual
  • 8 Packaging, transportation and storage

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

Please note that certain contents of this document may involve patents. Publication of this document The agency is not responsible for identifying these patents.

1 Scope

This standard specifies the terms and definitions, classification, technical requirements, and tests of nucleic acid extraction kits (magnetic bead method) (hereinafter referred to as "kits")

Method, identification, label and instruction manual, packaging, transportation and storage, etc.

This standard is applicable to the use of magnetic bead method from serum, plasma, whole blood, cerebrospinal fluid, breast milk, saliva, urine, sputum, swab, tissue or paraffin pack A kit for extracting and purifying human genome nucleic acid and its fragments, pathogen nucleic acid from various clinical samples such as buried tissue. Pathogen nucleic acid contains Deoxyribonucleic acid (DNA), ribonucleic acid (RNA), etc.

This standard does not apply to nucleic acid extraction reagents contained in a closed system where the nucleic acid extraction product cannot be taken out for testing.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated references, the latest version (including all amendments) applies to this document.

GB/T 29791.2 Information provided by manufacturers of in vitro diagnostic medical devices (labeling) Part 2: Professional in vitro diagnostic reagents

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Nucleic Acid

A class of biological macromolecules connected by nucleotides or deoxynucleotides through 3',5'-phosphodiester bonds, which have very important biological The function is mainly to store and transmit genetic information, including ribonucleic acid (RNA) and deoxyribonucleic acid (DNA).

3.2 Magnetic beads

The surface of superparamagnetic nanoparticles has been improved and modified to make it bind with nucleic acid molecules specifically and efficiently under different conditions.

Combining and dissociating, such superparamagnetic nanoparticles are called magnetic beads. Using this feature of magnetic beads, under the action of an external magnetic field, Separation and purification of nucleic acid DNA and RNA from the sample.

3.3 Extraction yield

A nucleic acid extraction kit (magnetic bead method) is used to extract the total amount of nucleic acid from a biological sample of a certain mass or volume.

3.4 Nucleic acid purity

The amount of nucleic acid relative to other impurities in the product extracted from a certain amount of biological sample with a nucleic acid extraction kit (magnetic bead method).

3.5 Precision

Under specified conditions, repeat measurements on the same or similar measured objects to obtain the measured values or the degree of agreement between the measured values.

Note 1.Measurement precision is usually represented by imprecision in numbers, such as standard deviation, variance and coefficient of variation under specified measurement conditions.

Note 2.Prescribed conditions such as measurement repeatability conditions, measurement intermediate precision conditions or measurement reproducibility conditions.

Note 3.Measurement precision is used to define measurement repeatability, intermediate measurement precision and measurement reproducibility.

Note 4.Repeated measurement refers to the results obtained on the same or similar samples in a way that is not affected by previous results. [GB/T 29791.1-2013, A.3 Supplementary Statistics and Analysis Terms]

4 Categories

4.1 Classification by extraction target type

According to the different types of extraction targets, it can be divided into human genomic DNA extraction kits, pathogen nucleic acid extraction kits and other nuclear There are three types of acid extraction kits; pathogen nucleic acid extraction kits can be divided into bacterial nucleic acid extraction kits and virus nucleic acid extraction reagents Boxes etc.

Note. Other types of nucleic acid extraction kits refer to multi-purpose kits that can extract both human genomic DNA and pathogen nucleic acid.

4.2 Classification by extraction target nucleic acid type

According to different types of extraction target nucleic acid, it can be divided into deoxyribonucleic acid (DNA) extraction kit and ribonucleic acid (RNA) extraction kit.

5 Technical requirements

5.1 Appearance

The appearance should meet the following conditions.

a) The kit should meet the appearance requirements specified by the manufacturer;

b) The kit should have complete components, clean packaging, no leakage, and no damage; signs and labels should be clearly written.

5.2 Quantity

The amount of liquid reagents should not be less than the value indicated on the label.

5.3 Extraction yield

The extraction yield of the kit should meet the extraction yield requirements specified by the manufacturer. The manufacturer shall stipulate the detection method for the extracted output. mention The yield should be described for a certain amount of samples. The certain amount of samples referred to here should be classified and expressed for different types of kits, such as liquids.

Sample application volume representation, tissue and other solid samples application quality representation, dried blood slice sample application area size expression, paraffin slice sample should be Use the slice thickness and the cell area to express together.

5.4 Nucleic acid purity

The purity of the nucleic acid extracted by the kit should meet the nucleic acid purity requirements specified by the manufacturer. Manufacturers should stipulate nucleic acid purity testing method.

5.5 Extraction efficiency

The extraction efficiency of the kit should meet the extraction efficiency requirements specified by the manufacturer. Manufacturers should specify extraction efficiency testing method.

5.6 Intra-run precision

The precision within the batch should be classified according to the following different categories.

a) Human genomic DNA (except serum or plasma free kit) extraction kit. use the kit to extract the company's self-calibration For the reference product, the repeatability error CV of the concentration value should not be greater than 15%;

b) Pathogen type nucleic acid extraction kit and serum or plasma free DNA extraction kit. use the kit to extract the company's own label The Ct value is obtained by using the fluorescence PCR reagent specified by the company to amplify the extract for the specified reference product, and the repeatability error CV is not large Less than 5%;

c) Other kits. the intra-assay precision of other kits that cannot be classified into the above two categories or whose concentration and Ct values cannot be obtained Meet the requirements of intra-run precision specified by the manufacturer. The manufacturer shall specify the testing method for the precision within the batch.

6 Test method

6.1 Appearance

Under natural light, visually inspect the appearance with normal vision or corrected vision, and the result should meet the requirements of 5.1.

6.2 Quantity

Use a universal measuring tool corresponding to the amount of liquid to measure, and the result should meet the requirements of 5.2.

6.3 Extraction yield

Use the kit to extract a certain amount of reference products calibrated by the company, and test the extraction yield according to the detection method specified by the company, and the results should match Meet the requirements of 5.3.

6.4 Nucleic acid purity

Use the kit to extract a certain amount of reference materials calibrated by the company, and detect the purity of the extracted nucleic acid according to the detection method specified by the company. The results should meet the requirements of 5.4.

6.5 Extraction efficiency

Use the kit to extract a certain amount of reference products calibrated by the company, and test the extraction efficiency according to the detection method specified by the company, and the results should match Meet the requirements of 5.5.

6.6 Intra-run precision

The intra-assay precision should be tested according to the following different categories.

a) Human genomic DNA (except serum or plasma free kit) extraction kit. use the kit to compare the same The company's self-calibrated reference product was subjected to nucleic acid extraction, a total of 10 times, and the concentration value was measured with an ultraviolet spectrophotometer. According to the data Calculate the repeatability error CV value, and the result should meet the requirements of 5.6a);

b) Pathogen-based nucleic acid extraction kit and serum or plasma free DNA extraction kit. use pathogen-based nucleic acid extraction reagents The kit and serum or plasma free DNA extraction kit are used to extract nucleic acid from the reference products calibrated by the same company according to the instructions.

Take, a total of 10 times, use the same fluorescent PCR instrument and the fluorescent PCR reagent designated by the company to amplify the detection extract, and detect Ct value, calculate the repeatability error CV value based on the data, and the result should meet the requirements of 5.6b);

c) Other types of kits. use the kit to extract a certain amount of reference materials calibrated by the company, and test in accordance with the detection method specified by the company The precision within the batch should meet the requirements of 5.6c).

7 Logo, label and instruction manual

Should meet the requirements of GB/T 29791.2.

8 Packaging, transportation and storage

8.1 Packaging

The kit should be packaged as required by the manufacturer.

8.2 Transportation

The kit should be transported as required by the manufacturer.

8.3 Storage

The kit should be stored as required by the manufacturer. references [1] GB/T 29791.1-2013 Information provided by manufacturers of in vitro diagnostic medical devices (labeling) Part 1: Terminology, definitions Yihe General Requirements (ISO 118113-1:2009, IDT)

[2] YY/T 0316-2016 Application of medical device risk management to medical devices (ISO 14971:2007, IDT)

[3] YY 0466.1-2016 Medical devices are used for medical device labeling, marking and providing information symbols. Part 1: General Application requirements (ISO 15223-1:2012, IDT)

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 1717-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1717-2020

$105.00