YY/T 1690-2020Determination of residual of ethylene chlorohydrin(ECH) from plasticized polyvinyl chloride infusion equipments for single use (English PDF)
一次性使用聚氯乙烯输注器具中2-氯乙醇残留量测定方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1690-2020 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
February 21, 2020
Implementation date
January 1, 2021
Scope
YY/T 1690-2020 is the English-translated version of 一次性使用聚氯乙烯输注器具中2-氯乙醇残留量测定方法.
YY/T 1690-2020 is the Chinese pharmaceutical industry standard that gives the method for determining residual 2-chloroethanol in single-use polyvinyl chloride infusion devices, the by-product left when ethylene oxide sterilization meets chloride.
It sets out the reagents, the extraction of the device, the gas chromatographic determination and the calculation of the residue per device, so that the limit set in the product standards can be checked.
It applies to PVC infusion devices sterilized with ethylene oxide. It was issued on 21 February 2020 and has applied since 1 January 2021.
Found what you need?
Document preview — YY/T 1690-2020
National Standard of the People's Republic of China
- ICS
- 11.040.30
- Classification
- C 31
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 General
- 4 Preparation of extract
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
Please note that certain contents of this document may involve patents. The issuing agency of this document is not responsible for identifying these patents.
Introduction
Ethylene oxide (EO) has a broad-spectrum and high-efficiency sterilization effect. It is one of the high-efficiency chemical low-temperature sterilants and is widely used in the sterilization of medical devices.
Pan application. However, ethylene oxide is a toxic substance, and many articles are adsorbent. The residual ethylene oxide is hydrolyzed and then interacts with the product. Chlorine reacts to produce 2-chloroethanol (ECH).
Data shows that ECH is a flammable liquid that irritates the body surface, has acute toxicity, and is quickly absorbed through the skin at a toxic dose. body. ECH is slightly mutagenic, has the potential to produce fetal toxicity and teratogenic changes, and can cause damage to several organ systems in the body.
Injuries include lungs, kidneys, central nervous system and cardiovascular system. At present, GB/T 16886 specifies when using EO sterilized medical devices When ECH exists in the machine, the maximum allowable residual amount of ECH should also be specified.
A variety of analytical methods can be used to determine the residual amount of ECH, typical methods include gas chromatography (GC), gas chromatography/mass spectrometer combined Usage (GC/MS) etc. This standard uses headspace gas chromatography as the basic method and gives test procedures.
Due to the large differences in the clinical application of such devices, in some cases, the published literature methods include those given in this standard.
The method presented may not be applicable to all devices. Therefore, any method that shows that its analysis is reliable can be used. "Analytical reliability" means When the extraction liquid obtained under specific extraction medium and conditions is analyzed for ECH residual content, the selected method has sufficient precision, Accuracy, linearity, sensitivity and selectivity. Disposable PVC infusion equipment Determination method of 2-chloroethanol residue
1 Scope
This standard specifies the method for the determination of 2-chloroethanol (ECH) residues in disposable polyvinyl chloride infusion devices.
This standard applies to disposable polyvinyl chloride infusion devices sterilized with ethylene oxide.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated references, the latest version (including all amendments) applies to this document.
GB/T 6682 Analytical laboratory water specifications and test methods
GB/T 12808 Single-marked pipette for laboratory glassware
3 General
3.1 The room temperature in this standard, unless otherwise specified, should be 10°C~30°C.
3.2 The test water in this standard should meet the requirements of GB/T 6682.
3.3 The containers used in this standard shall be borosilicate glass containers if there are no special regulations.
3.4 The precision measurement involved in this standard should be measured with a pipette that meets the accuracy requirements in GB/T 12808.
4 Preparation of extract
4.1 General
There are two basic extraction methods used to determine the ECH residues of medical devices. The simulated use of extraction is the standard method, and the limit extraction Law is an acceptable alternative in certain situations. The selected extraction method should be able to represent the greatest risk to patients in the expected use of the product It is not only the pursuit of analysis efficiency or minimizing the apparent concentration of residues.
Small instruments should be placed in a suitable container for extraction. When the device is too large for complete extraction, it may be necessary to select several representative The device components are extracted to ensure the credibility of the data.
To select a representative part of the device, either of the following two methods can be used. If it contains several different materials, each group The proportion of the total mass of the sample should be consistent with the proportion of the total mass of the component in the total mass of the device under test. Another alternative is to choose The evaluation certificate is to test the component with the highest residual content on the device, and the selected method should be confirmed.
4.2 Simulated extraction (standard method)
Use the discussed liquid that represents the most unfavorable actual clinical contact and the extraction method and conditions for extraction, and then take part of the extraction The extract is tested. In the simulated use extraction method, water is usually used as the extraction liquid.
Due to the large differences in the clinical use of the equipment, especially the actual contact of the infusion equipment with a wide variety of media, the simulated immersion When mentioning, if the test medium produces interference under the test conditions specified in Chapter 5, other conditions demonstrated by methodology should be used.
4.3 Ultimate extraction (acceptable alternative method)
The limit extraction method is used to determine the total amount of residue on the device. The limit extraction method is an acceptable alternative and can provide useful information.
Information, the measured results indicate greater than or equal to the patient's acceptable dose. Because this extraction method eliminates the influence of time on dosimetry There is no guarantee that most of the residual amount measured will be released to the patient on the first day of contact with the device or at the end of the first month.
Note. If the limit extraction test results exceed the maximum allowable human dose, consider using simulated extraction (4.2) to prepare extracts for further testing.
5 Recommended determination method---limit extraction headspace gas chromatography
5.1 Reagents
ECH reference substance. purity not less than 95.0%, CAS number. 107-07-3.
5.2 Apparatus and equipment
Headspace-gas chromatograph (FID detector).
5.3 Working standard solution
Take a dry and clean 100mL volumetric flask, add about 40mL water, add a stopper, and accurately weigh. Take a certain amount of ECH and add capacity In the bottle, do not add the stopper, shake it gently, cover the stopper, and weigh it accurately. The difference between the two weighings is the weight of ECH contained in the solution. add water To the mark, prepare a standard stock solution with a concentration of about 2000mg/L.
Prepare ECH series standard solutions with a concentration range of 4mg/L~100mg/L with standard stock solution, and prepare at least 5 concentrations.
5.4 Gas chromatographic conditions (recommended)
5.4.1 Headspace conditions
a) Heating box temperature. 90°C;
b) Heating time. 30min.
5.4.2 Chromatographic conditions
a) Capillary column. 6% cyanopropyl phenyl-94% dimethyl polysiloxane (30m×0.25mm×1.4µm) or equivalent color Spectrum column;
Note. If an equivalent column is used, the chromatographic conditions may be inconsistent.
b) Inlet temperature. 250°C;
c) Injection volume. 1mL; Split ratio. 5.1;
d) Oven temperature. hold at 50°C for 3min, heat up to 100°C at a rate of 10°C/min, hold for 2min;
e) Flow rate. 1.5mL/min; Carrier gas. N2;
f) Detector. FID; temperature. 300°C.
5.5 Measurement and result analysis
5.5.1 Preparation of test solution
Take the complete product or representative parts for the test, cut into 0.5cm long pieces (or 10mm² flakes), take 1.0g into 20mL In the headspace bottle, precisely add 5 mL of water, seal, and equilibrate at 90°C for 30 min.
5.5.2 Determination of standard solutions and samples
Take 5mL each of the prepared standard solution and the prepared test solution, place them in a 20mL headspace bottle and seal them according to the headspace conditions and chromatography Condition determination.
5.5.3 Quantitative analysis
The external standard method is used to analyze the working standard solution and sample solution respectively, establish the working standard curve and regression equation, and calculate the sample The residual amount of ECH. ECH residual content can be expressed in absolute content or relative content.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 1690-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12808-2015 — Laboratory glassware - One mark pipettes
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
Secure payment via Stripe
Payments accepted
YY/T 1690-2020
$85.00