YY/T 1550.1-2017 is the Chinese pharmaceutical industry standard that describes how the sorption of a drug by a single-use infusion device is studied, that is how much of the drug is taken up by the tubing and the other parts on its way to the patient.
It is the first part of the YY/T 1550 series and sets out the preparation of the drug solution, the infusion under clinical or simulated clinical conditions, the sampling of the effluent and the comparison with a control, so that the loss can be quantified. Issued on 28 February 2017, it has applied since 1 January 2018.
Found what you need?
Document preview — YY/T 1550.1-2017
National Standard of the People's Republic of China
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword3
- Introduction4
- 1 Scope5
- 2 Normative references5
- 3 Terms and definitions5
- 4 Test methods6
- 5 Study report content8
Introduction
The compatibility study of infusion equipment and pharmaceutical products includes the study of drug sorption by equipment in the infusion process, and the study of leachable substances in the migration from equipment to drugs.
This part only deals with drug sorption studies for infusion equipment.
Guidelines for the study of leachable substance migrated from the equipment to the drugs will be given elsewhere in this series of standards.
Intravenous infusion is a unique method of drug provision that directly enters the body's blood circulatory system without passing through any biological barrier. The sorption of drugs on infusion equipment during clinical use will directly affect the therapeutic effect of drugs, i.e., effectiveness, especially for low-dose drugs. In addition, some treatments that require precise drug delivery, such as insulin or some highly toxic drugs, if sorption and desorption action occur in the infusion process, can cause doses at some time points to exceed the expected dose. Therefore, it is of great significance to establish and formulate guidelines for the study of the compatibility of drugs and devices, and to scientifically and standardly evaluate the compatibility of devices and drugs in drug delivery process.
Due to the wide variety of infusion drugs and the great differences in the clinical application of different infusion equipment, it is not possible to present a test method that is applicable to the compatibility study of all drugs and infusion equipment. When conducting drug compatibility studies of specific drugs and infusion devices, reference may be made to the method given in YY/T 1550, and other test methods with sufficient precision, accuracy, linearity, and sensitivity may also be selected.
1 Scope
This part of YY/T 1550 gives the study method of drug sorption during the process of contacting the single-use infusion device with drugs under the conditions of simulated clinical infusion or clinical actual infusion conditions.
This part applies to the study of drug sorption in the compatibility study between a specific infusion device and the drug to be infused or the typical drug selected after demonstration.
2 Normative references
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard.
GB/T 6682 Water for analytical laboratory use - Specification and test methods
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Drug compatibility
The evidence of no serious interactions between the infusion set and the drug that leads to changes in efficacy and stability or to toxicological risk.
3.2 Sorption
Sorption studies typically characterize changes in drug efficacy by measuring changes in drug concentration in infusion solution. For some treatment processes that require precise drug delivery, such as insulin or certain highly toxic drugs, it is advisable to consider determining the appropriate sampling time point to examine the sorption and desorption of the drug by infusion devices at different time points.
4 Test methods
4.2.1 Methodology study item
It should use the confirmed test methods to determine drug concentration changes in drug components in infusion solution. Generally, priority is given to the determination method of the drug content in the drug preparations to be studied. The commonly used drug content analysis methods include high performance liquid chromatography (HPLC), gas chromatography (GC or GC/MS), visible UV spectrophotometry (Vis-UV), and the like. The proposed method for concentration determination shall consider at least the following relevant methodological study items.
4.2.1.1 Specific properties
The auxiliary ingredient, related substances in the pharmaceutical preparations, infusion carriers during the preparation of the extracts, and potential leachable substances in the infusion instruments shall not interfere with the determination of the drug content. It should use appropriate methods to verify the specificity of the method to be used for determination of the content. For example, when the HPLC method is used to determine the drug content, the separation study of the system suitability test, the comparation of solution chromatogram of infusion carrier passing through the infusion device before and after adding the drug preparations.
4.2.1.2 Precision
It should use appropriate methods to examine the precision of the method to be used for determination of the content, for example, the same test solution is determined continuously for not less than 6 times, and the relative standard deviation (RSD) is calculated.
4.2.1.3 Stability
The change in drug concentration of the drug control solution is determined at least before and at the end of the experiment, to confirm the stability of the drug control solution itself that has not been in contact with the infusion set throughout the entire test period.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download YY/T 1550.1-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
YY/T 1550.2-2019 — Guidance on the study of compatibility between infusion equipment and pharmaceutical products - Part 2: Leachables - Known substances
Secure payment via Stripe
Payments accepted
YY/T 1550.1-2017
$75.00