Scope

YY/T 1258-2015 is the English-translated version of 同型半胱氨酸检测试剂(盒)(酶循环法).

YY/T 1258-2015 is the Chinese pharmaceutical industry standard for the homocysteine assay kit based on the enzymatic cycling method.

It specifies the requirements, the test methods, the labels, the instructions and the rules for packaging, transport and storage, covering the appearance, the blank absorbance, the traceability of the calibrator, the accuracy, the linear range, the precision, the interference and the stability of the reagents. Issued on 2 March 2015, it has applied since 1 January 2016.

Found what you need?

Document preview — YY/T 1258-2015

National Standard of the People's Republic of China

ICS
11.100
Classification
C 44

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative reference documents
  • 3 Request

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This standard specifies the requirements for homocysteine assay reagents (enzyme) (enzyme cycle), test methods, labels, instructions, packaging, Transportation and storage.

This standard is applicable to reagents (cartridges) for quantitative detection of homocysteine in human serum or plasma using an enzyme circulation method, The principle of photometric method, including manual reagents and reagents used in semi-automatic, fully automated biochemical analyzers.

2 Normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.

YY/T 0466.1 Symbols for medical devices for labeling, labeling and providing information on medical devices - Part 1. General requirements

3 Request

3.1 Appearance

Appearance should meet the following requirements.

a) kit components should be complete, complete, liquid without leakage;

b) packaging label text symbols should be clear.

3.2 Capacity

Should not be less than the marked value.

3.3 Reagent blank

The initial absorbance of the reagents for the ascending reaction is not greater than 0.05, and the initial absorbance of the reagent for the descending reaction is not less than 0.8.

3.4 Analysis of sensitivity

For the endpoint test, the absorbance change (deltaA) of the 10.0 µmol/L sample should be not less than 0.02.

For the rate test reagent, the absorbance change rate (deltaA/min) of the 10.0 µmol/L sample should be not less than 0.01.

3.5 Linearity

The linear range of reagent (box) should be covered [3.0,45.0] µmol/L.

a) linear correlation coefficient ︱ r︱ should not be less than 0.995;

b) The linear deviation should not exceed ± 1.0 µmol/L or the linear deviation should not exceed ± 10%.

3.6 Precision

3.6.1 Repeatability

3.6.1.1 Repeat the test (10.0 ± 2.0) µmol/L of the sample, the results of the coefficient of variation (CV) should not be greater than 5%.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 1258-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 1258-2015

$169.00