YY/T 1218-2013Thyroid-stimulating hormone quantitative labelling immunoassay kit (English PDF)
促甲状腺素定量标记免疫分析试剂盒
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YY/T 1218-2013 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
October 21, 2013
Implementation date
October 1, 2014
Scope
YY/T 1218-2013 is the English-translated version of 促甲状腺素定量标记免疫分析试剂盒.
YY/T 1218-2013 is the Chinese pharmaceutical industry standard for the kit that measures thyroid-stimulating hormone quantitatively by a labelled immunoassay.
It specifies the classification, the requirements, the test methods, the marking, the labelling, the instruction manual and the rules for packaging, transport and storage, covering the appearance, the traceability of the calibrator, the accuracy, the linear range, the detection limit, the precision, the hook effect and the stability. Issued on 21 October 2013, it has applied since 1 October 2014.
Found what you need?
Document preview — YY/T 1218-2013
National Standard of the People's Republic of China
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Classifications4
- 4 Requirements5
- 5 Test methods6
- 6 Identifications, labels and instructions8
- 7 Packaging, transportation and storage10
- Bibliography11
Foreword
This Standard is drafted according to the rules specified in GB/T 1.1-2009.
1 Scope
This Standard specifies the classification, requirements, test methods, marks, labels, instructions, packaging, transportation, and storage of the thyroid-stimulating hormone quantitative labelling immunoassay kit.
This Standard is applicable to the quantitative determination of thyroid-stimulating hormone (TSH) kit (hereinafter referred to as "TSH kit") based on the principle of double antibody sandwich method. It includes the immunoassay kit for quantitative determination of TSH by using labelling methods such as enzyme labelling, (electrical) chemiluminescent labelling, and (time resolution) fluorescence labelling AS capture antibody; and taking microplates, pipes, magnetic particles, microbeads and plastic beads etc. AS the carrier coated antibody. This Standard does not apply to.
a) Colloidal gold labelled TSH test strip;
b) Various types of radio-immunity or IRMA kit labelled with 125I and other radioactive isotopes.
2 Normative references
The articles contained in the following documents have become part of this Document when they are quoted herein. For the dated documents so quoted, all the modifications (Including all corrections) or revisions made thereafter shall be applicable to this document.
YY/T 0466.1-2009 Medical devices -- Symbols to be used with medical device labels, labelling and information to be supplied -- Part 1. General requirements
3 Classifications
According to different labelling methods, TSH kit can be divided into the enzyme-labelled TSH kit, (electrical) chemiluminescent labelled TSH kit, (time resolution) fluorescence labelled TSH kit and the like. According to the solid carrier, it can be divided into TSH kits with carriers of microplates, pipes, magnetic particles, microbeads, and plastic beads etc.
Two or three quality control products are set up in different areas of dose-response curves.
The coefficient of variation (CV) of measured value of quality control products shall comply with the provision of 4.5.2, among not-less-than 3-times independent analysis. The calculation method is the same as 5.5.1.
Note: "Among Independent analysis" include. Among different independent experiments, among different time periods within the validity of the kit, among different experiments with the same operator, and among different operators, etc.
5 Test methods
5.5.3 Precision between-batches
Two or three quality control products are set up in different areas of dose-response curves.
The coefficient of variation (CV) of measured value of quality control products shall comply with the provision of 4.5.2, among at least 3 batches of products for independent analysis. The calculation method is the same as 5.5.1.
5.6 Measured value of quality control products
Two or three quality control products are set up in different areas of dose-response curves.
The measured results of the kit shall comply with the provision of 4.6.
5.7 Specificity
The sample with specificity shall be prepared to a prescribed concentration by using the kit buffer system. The measured results of the kit shall comply with the provisions of 4.7.1, 4.7.2 and 4.7.3.
5.8 Stability
After the kit is preserved according to the provisions of 4.8.1 or 4.8.2, the inspection results shall comply with the provisions of 4.1, 4.2, 4.3, 4.4, 4.5.1, 4.5.2 and 4.6.
6 Identifications, labels and instructions
6.1 The identifications and labels of the kit's external packaging boxes shall comply with the provision of YY/T 0466.1, and at least contain the following contents.
a) Product name and specification;
b) Name, address and contact information of manufacturers;
c) Medical device registration certificate number and product standard number;
d) Product batch number;
e) Period of validity;
Bibliography [1] GB/T 3358.1 Statistical terms - Part 1. General statistical terms and terms used in probability [2] JJF 1001-2011 General Terms in Metrology and Their Definitions [3] Ye Yingwu. National Guide to Clinical Laboratory Procedures Third Edition Nanjing.
Southeast University Press, 2006 [4] YY/T 0316-2008 Medical Devices - application of risk management to medical devices [5] State Pharmacopoeia Commission. General principles of the radiation immunoassay kit, 2005 [6] State Pharmacopoeia Commission. Requirements for China Biological Products (2000 Edition)
[7] Guo Zuchao. Medical mathematical statistical method; Third Edition; Beijing. People's Medical Publishing House, 1988 […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 1218-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0466.1-2009 — Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0479-2026 — Medical diagnostic X-ray tube assemblies and X-ray source assemblies - Determination of maximum symmetric radiation field
Secure payment via Stripe
Payments accepted
YY/T 1218-2013
$125.00