YY/T 0972-2016Active implantable medical devices-Four-pole connector system for implantable cardiac rhythm management devices-Dimensional and test requirements (English PDF)
有源植入医疗器械植入式心律调节设备用四极连接器系统尺寸和试验要求
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0972-2016 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
March 23, 2016
Implementation date
January 1, 2017
Scope
YY/T 0972-2016 is the English-translated version of 有源植入医疗器械植入式心律调节设备用四极连接器系统尺寸和试验要求.
YY/T 0972-2016 fixes the dimensions and the tests for the four-pole connector system used between an implantable lead and an implantable pulse generator for pacing, sensing and defibrillation.
It gives the basic dimensions and performance requirements of the lead connector and of the connector cavity, the gauges used to check them, and the test methods for the two mating parts, with annexes on electrical isolation, dielectric strength, high-voltage current carrying, connector fatigue strength, sealing area material, seal zone creep, contact resistance stability and contact material requirements, referring to ASTM F562 and stainless steel data.
It does not replace the unipolar and bipolar connector standards, and it does not apply to systems delivering more than 1 000 V or 50 A, nor to sensors or special electrodes outside pacing, sensing and defibrillation.
Modified from ISO 27186:2010, it was issued on 23 March 2016 and has applied since 1 January 2017.
Found what you need?
Document preview — YY/T 0972-2016
National Standard of the People's Republic of China
- ICS
- 11.040.40
- Classification
- C 31
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Preface
- 1 Scope
- 2 normative reference document
- 3 Terms and definitions
- 4 requirements
- Appendix A (Normative Appendix) Electrical Isolation Test
- Appendix B (informative) Basic principles of Appendix A
- Appendix C (Normative Appendix) Dielectric Strength Test
- Appendix D (informative) Basic principles of Appendix C
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses the re-drafting method to modify the use of ISO 27186.:2010 (first edition) "active implantation of medical devices implantable cardiac rhythm Device quadrupole connector system size and test requirements ".
The main differences between this standard and ISO 27186.:2010 (first edition) are as follows.
--- For the standard cited in the standard, if China has been converted into domestic standards, then refer to our standards;
--- According to the Chinese version of the requirements, page number, font and font size, etc. have been modified, does not affect the degree of consistency;
1 Scope
This standard applies to quadrupole connector systems for implantable pacemaker devices with pacing, ECG perception and/or defibrillation. This standard Specifies the requirements for the part of the implantable electrode lead connector and the requirements for the inner cavity of the connector attached to the enclosed implanted pulse generator.
Set the basic dimensions and performance requirements and their adaptation test methods.
This standard is not intended to replace existing unipolar or bipolar connector standards (eg ISO 11318 and YY/T 0491). This standard does not Suitable for systems that can output high voltages above 1000V and/or 50A. This standard does not apply to those who do not support traditional pacing, ECG Knowledge and/or defibrillation function of the sensor or special electrode system.
This standard does not specify all connector characteristics. The standard is not clear functional compatibility, electrode wire safety and reliability and pulse generator with System adaptation requirements.
WARNING - If the implantable pulse generator is able to conduct a dangerous non-pacing stimulus signal through the contact portion of the lumen (eg, Defibrillation), it is not possible to use the connector cavity for low voltage only specified in this standard. Likewise, this standard provides for High voltage electrode connectors can not be used in electrode lines for low voltage therapy.
Note. Electrode conductors and pulse generator connectors that do not meet this standard may be safe, reliable, and may have clinical advantages.
2 Normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 74. 1985 Slotted terminal set screws (ISO 7436. 1983, MOD)
ASTMA276 stainless steel bar and profile standard (StandardSpecification forStainlessSteelBarsand Shapes Standard Specification for Titanium and Titanium Alloy Rods and Billets (StandardSpecification for Titaniumand TitaniumAloyUGISanobilets)
ASTM F562 Standard Specification for Forged Cobalt-Chromium-Molybdenum Alloy for Surgical Implantation (StandardSpecification forWught)
35Cobalt-35Nickel-20Chromium-10MolybdenumAloyforSurgicalImplantApplications ASTM F746-04 Standard Test Method for Dent or Fissure Corrosion of Metallic Surgical Implants (StandardTestMethod forPittingorCreviceCorrosionofMetalicSurgicalImplantMaterials)
Standard Test Method for Evaluation of Connection Properties of Electrical Conductor Materials by ASTMB896 (StandardTestMethods forEvaluating ConnectabilityCharacteristicsofElectricalConductorMaterials)
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Needle axial movement
In some designs, particularly in the design with a rotatable connector pin, the electrode lead connector pin is connected to the electrode lead connector body
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Normative references
ASTM A276 · ASTM B348 · ASTM F562 · ASTM F746-04 · ASTM B896
Similar standards
How to Download YY/T 0972-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0479-2026 — Medical diagnostic X-ray tube assemblies and X-ray source assemblies - Determination of maximum symmetric radiation field
YY/T 0492-2026 — Implantable leads
Secure payment via Stripe
Payments accepted
YY/T 0972-2016
$1,210.00