YY/T 0865.3-2013Ultrasonics—Hydrophones - Part 3: Properties of hydrophones for ultrasonic fields up to 40 MHz (English PDF)
超声水听器 第3部分:40MHz以下超声场用水听器的特性
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0865.3-2013 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
October 21, 2013
Implementation date
October 1, 2014
Scope
YY/T 0865.3-2013 is the English-translated version of 超声水听器 第3部分:40MHz以下超声场用水听器的特性.
YY/T 0865.3-2013 is the Chinese pharmaceutical industry standard that sets the performance requirements for hydrophones used to measure ultrasonic fields up to 40 MHz.
It is the third part of the YY/T 0865 series and covers the sensitivity of the hydrophone and its frequency response, the effective element size and the directional response, the linearity and the noise, and the information that must accompany a calibrated hydrophone. Issued on 21 October 2013, it has applied since 1 October 2014.
Found what you need?
Document preview — YY/T 0865.3-2013
National Standard of the People's Republic of China
- ICS
- 11.040.50
- Classification
- C 41
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
Foreword
YY/T 0865 "ultrasonic hydrophone" is divided into three parts.
--- Part 1. Measurement and the following features 40MHz medical ultrasound depicted;
--- Part 2. 40MHz or less water ultrasound hydrophone calibration;
Part --- Section 3. 40MHz or less water ultrasound hydrophone characteristics. This section YY/T Section 30865 of. This section drafted in accordance with GB/T 1.1-2009 given rules.
This section is equivalent to using the International Electrotechnical Commission standard IEC 62127-3:2007 "ultrasonic hydrophone - Part 3. 40MHz or less Ultrasound hydrophone water features. " Correspondence between the consistency of the standards of international documents and normative references of the following documents.
YY/T 0865.1-2011 ultrasonic hydrophone - Part 1. Measurement and characterization of medical ultrasonic fields of 40MHz or less portrayed (IEC 62127-1:2007, IDT)
This part of IEC 62127-3:2007 only made a very small amount of editorial changes did not affect the degree of consistency.
Introduction
Usually miniature ultrasonic hydrophones measuring space and time ultrasonic liquid medium field sound pressure distribution, many of those involved in the IEC standard Hydrophone various aspects of the device characteristics. Objective YY/T 0865 of this section is. the sum of all these requirements, for hydrophone characteristics establish a Parts of common standards. The main application areas of this part of the hydrophone is. measuring ultrasonic fields in water by the medical diagnostic equipment emits. Other doctors Science application areas are. treatment equipment, such as crushed stone, high-intensity focused ultrasound (HIFU) and sound field measurements treatments. In non-medical applications, Hydrophone in product development and quality control and other aspects are also widely used, including.
--- Ultrasonic cleaning tank super sound field depicted;
--- In the emission measurement system, the use of the characteristics of the sound field rendering (for example, an ultrasonic spectrometer, ultrasonic attenuation meter and speedometer);
--- In the reflection measurement system, used in depicting the characteristics of the sound field (for example, Doppler flow meter).
At the same time, the term "hydrophone" more widely understood here relates to a miniature piezoelectric hydrophone. Currently this type of instrument, in Application of ultrasound in various fields, especially for quantitative medical diagnostic equipment sound field structure is depicted. Other types of pressure sensors, such as one based The principle of fiber, some of the requirements of this section apply, others do not apply. If in the future these other "hydrophone" type of sound field measurements Occupy a more important role in the revision of the standard or independent of this part will be related to their properties.
Underwater acoustic hydrophone by the IEC 60500 and IEC 60565 covered, although there is overlap in the frequency range, but does not belong to this part of the Fan Domains. Underwater acoustic hydrophone for natural waters, even the ocean, which led to different technical concepts and requirements. In addition, the application of acoustic sound of water The main direction of the incident is generally perpendicular to the axis of acoustic hydrophone and assume in this section, which is located on the hydrophone axis.
In the past, ultrasound hydrophones used almost exclusively amplitude sensor, the current situation has changed, even more attention to the use of their additional phase information, However, only during the calibration may be used to determine the phase characteristics when the hydrophone. Therefore, in this section, in addition to the provisions of the hydrophone Sensitivity margin requirements, but as an option, phase requirements are also suggested. Ultrasonic hydrophone Part 3. 40MHz of ultrasonic field water hydrophone characteristics
1 Scope
YY/T 0865 this part of the provisions of the relevant hydrophone performance requirements. This section applies to.
--- Piezoelectric sensor, designed for measuring ultrasonic pulse produced by the device and continuous wave ultrasonic field hydrophone;
--- For measurements in the water hydrophone;
--- Mating or mating preamplifier hydrophone.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
IEC 62127-1 ultrasonic hydrophone Part 1. Measurement and characterization of medical ultrasonic fields 40MHz The following depiction (Ultrasonics- Hydrophones-Part 1. Measurementandcharacterizationofmedicalultrasonicfieldsupto40MHz)
IEC 62127-2 ultrasonic hydrophone Part 2. Calibration 40MHz of ultrasonic field (Ultrasonics-Hydrophones- Part 2. Calibrationforultrasonicfieldsupto40MHz)
3 Terms and Definitions
The following terms and definitions apply to this document.
Note: IEC 62127-1 and related definitions included in IEC 62127-2 apply to this section.
3.1 Directional response
In the center designated by the reference plane at the specified frequency, hydrophone response relationship between the direction of propagation of acoustic waves in the plane of incidence Description, usually graphically represented.
Note: See IEC 60565:2006.
3.2 Effective hydrophone radius
ah, ah3, ah6 The radius of the rigid element-receiving hydrophone, the angular width of their expected directional response function is equal to the observed angular width. Unit. m, m
Note 1. The angular width of the directional response function below a specified value of the peak is determined to specify the value of 3dB and 6dB radius respectively ah3 and ah6 FIG.
Note 2. The radius is usually a function of frequency, typical experimental data, see [1].
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
IEC 62127-1 · IEC 62127-2
Similar standards
How to Download YY/T 0865.3-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0865.2-2018 — Ultrasonics—Hydrophones - Part 2: Calibration for ultrasonic fields up to 40 MHz
YY/T 0865.1-2011 — Ultrasonic—Hydrophone - Part 1: Measurement and characterization of medical ultrasonic fields up to 40 MHz
YY/T 0865.1-2024 — Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields
Secure payment via Stripe
Payments accepted
YY/T 0865.3-2013
$255.00