YY/T 0841-2023Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment (English PDF)
This is a limited preview
Buy now to download the full PDF (50 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0841-2023 in 30 minutes.
Issued by
National Medical Products Administration
Level / Type
National · Recommended
Issue date
September 5, 2023
Implementation date
September 15, 2025
Scope
YY/T 0841-2023 (Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment) is available as an English-translated PDF.
YY/T 0841-2023 — This document specifies testing of medical electrical equipment and medical electrical system (hereafter referred to as ME equipment and ME systems) or parts of such equipment or systems, which comply with GB 9706.1, before putting into service, during maintenance, during inspection, after repair and in other services, or on occasion of recurrent tests.
Found what you need?
Document preview — YY/T 0841-2023
National Standard of the People's Republic of China
- ICS
- 11.040
Issued by: National Medical Products Administration
Contents
- Foreword...3
- Introduction...5
- 1 Scope...6
- 2 Normative references...6
- 3 Terms and definitions...7
- 4 Requirements...18
- 4.1 * General requirements...18
- 4.2 Testing before putting into service, after modifications, and after repair...20
- 4.3 * Recurrent test...20
- 5 * Tests...21
- 5.1 General...21
- 5.2 Visual inspection...21
- 5.3 Measurements...22
- 5.4 Functional test...36
- 6 Results of test and evaluation...37
- 6.1 Reporting of results...37
- 6.2 Evaluation...37
- Annex A (Informative) General guidance and rationale...39
- Annex B (Informative) Sequence of testing...50
Foreword
This document is drafted in accordance with the rules provided in GB/T 1.1-2020
Directives for standardization - Part 1.Rules for the structure and drafting of
standardizing documents.
This document replaces YY/T 0841-2011 Medical electrical equipment - Recurrent test
and test after repair of medical electrical equipment. Compared with YY/T 0841-2011,
in addition to structural adjustment and editorial modification, the main technical
revisions are as follows.
-- Add the definitions of "configuration" and "line-to-earth voltage" (see 3.8 and
3.17);
-- Add some terms in GB 9706.1-2020 (see 3.28, 3.31, 3.33, 3.35);
-- Delete the definition of "normal condition" (see 3.26 of the 2011 edition);
-- Change the measuring of protective earth resistance to adapt to the test of ME
systems in GB 9706.1-2020 (see 5.3.2; 5.3.2 of the 2011 edition);
-- Add the measurement of insulation resistance (see 5.3.3);
-- Add the method of measuring the equipment leakage currents, and explain the
relevant contents (see 5.3.4.1);
-- Add some required values (see Table 2).
This document adopts IEC 62353.2014 Medical electrical equipment – Recurrent test
and test after repair of medical electrical equipment by modification.
The technical differences between this document and IEC 62353.2014 and their reasons
are as follows.
-- Use the normatively referenced GB 9706.1 to replace IEC 60601-1.2005 and
IEC 60601-1.2005+AMD 1.2012 to adapt to our country's technical conditions;
-- Use the normatively referenced GB 4793.1 to replace IEC 61010-1 (see Annex
C) to adapt to our country's technical conditions;
-- Use the normatively referenced GB 4793.5 to replace IEC 61010-031 (see
Annex C) to adapt to our country's technical conditions;
-- Use the normatively referenced GB/T 17045 to replace IEC 61140 (see 6.2) to
adapt to our country's technical conditions;
-- Use the normatively referenced GB/T 18216.1 to replace IEC 61557-1 (see
Annex C) to adapt to our country's technical conditions;
-- Use the normatively referenced GB/T 18216.2 to replace IEC 61557-2 (see
Annex C) to adapt to our country's technical conditions;
-- Use the normatively referenced GB/T 18216.4 to replace IEC 61557-4 (see
Annex C) to adapt to our country's technical conditions.
The following editorial changes have also been made to this document.
-- Delete some explanatory content in the Scope and move it to the Introduction;
-- Move the general requirements for testing from the Scope to 4.1;
-- Use the informatively referenced GB/T 5465.2 to replace IEC 60417 (see 3.45,
3.46, 3.47, Annex A);
-- Add some notes.
1 Scope
This document specifies testing of medical electrical equipment and medical electrical
system (hereafter referred to as ME equipment and ME systems) or parts of such
equipment or systems, which comply with GB 9706.1, before putting into service,
during maintenance, during inspection, after repair and in other services, or on occasion
of recurrent tests.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this
document and are indispensable for its application. For dated references, only the
edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies.
GB 4793.1, Safety requirements for electrical equipment for measurement,
control and laboratory use - Part 1.General requirements (GB 4793.1-2007, IEC
61010-1.2001, IDT)
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
Some of the definitions are necessarily different from those in GB 9706.1, as
different measuring methods are used.
4 Requirements
The responsible party may omit certain tests based on manufacturers' written
information or accompanying documents.
ME systems shall be visually inspected to determine whether the ME system
configuration is still the same as at the time of the last inspection, or whether any
equipment making up the ME system has been exchanged, added or removed.
5 Tests
For Class I ME equipment, it shall be demonstrated that the protective earth conductor
connects all accessible conductive parts, which may become live in case of a fault, in a
proper and safe way to either the protective earth terminal of the mains plug for
plugged-in equipment or to the protective earth point for permanently installed
equipment.
ME equipment is separated from mains, and the equipment leakage current is measured
according to Figure 6.
6 Results of test and evaluation
The evaluation of safety of ME equipment or ME system shall be performed by
electrically skilled persons (as defined in GB 17045) who have the appropriate training
for testing the equipment under test. If using the measurement equipment listed in
Annex C, measurement uncertainties do not need to be taken into consideration for the
limits.
Annex A
(Informative)
General guidance and rationale
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 50 pages — is available in the English PDF.
Referenced standards
Normative references
GB 4793.1 · GB 4793.1-2007
How to Download YY/T 0841-2023
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
YY/T 0479-2026 — Medical diagnostic X-ray tube assemblies and X-ray source assemblies - Determination of maximum symmetric radiation field
YY/T 0492-2026 — Implantable leads
Secure payment via Stripe
Payments accepted
YY/T 0841-2023
$915.00