YY/T 0841-2023Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (50 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0841-2023 in 30 minutes.

Issued by

National Medical Products Administration

Level / Type

National · Recommended

Issue date

September 5, 2023

Implementation date

September 15, 2025

Scope

YY/T 0841-2023 (Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment) is available as an English-translated PDF.

YY/T 0841-2023 — This document specifies testing of medical electrical equipment and medical electrical system (hereafter referred to as ME equipment and ME systems) or parts of such equipment or systems, which comply with GB 9706.1, before putting into service, during maintenance, during inspection, after repair and in other services, or on occasion of recurrent tests.

Found what you need?

Document preview — YY/T 0841-2023

National Standard of the People's Republic of China

ICS
11.040

Issued by: National Medical Products Administration

Contents

  • Foreword...3
  • Introduction...5
  • 1 Scope...6
  • 2 Normative references...6
  • 3 Terms and definitions...7
  • 4 Requirements...18
  • 4.1 * General requirements...18
  • 4.2 Testing before putting into service, after modifications, and after repair...20
  • 4.3 * Recurrent test...20
  • 5 * Tests...21
  • 5.1 General...21
  • 5.2 Visual inspection...21
  • 5.3 Measurements...22
  • 5.4 Functional test...36
  • 6 Results of test and evaluation...37
  • 6.1 Reporting of results...37
  • 6.2 Evaluation...37
  • Annex A (Informative) General guidance and rationale...39
  • Annex B (Informative) Sequence of testing...50

Foreword

This document is drafted in accordance with the rules provided in GB/T 1.1-2020

Directives for standardization - Part 1.Rules for the structure and drafting of

standardizing documents.

This document replaces YY/T 0841-2011 Medical electrical equipment - Recurrent test

and test after repair of medical electrical equipment. Compared with YY/T 0841-2011,

in addition to structural adjustment and editorial modification, the main technical

revisions are as follows.

-- Add the definitions of "configuration" and "line-to-earth voltage" (see 3.8 and

3.17);

-- Add some terms in GB 9706.1-2020 (see 3.28, 3.31, 3.33, 3.35);

-- Delete the definition of "normal condition" (see 3.26 of the 2011 edition);

-- Change the measuring of protective earth resistance to adapt to the test of ME

systems in GB 9706.1-2020 (see 5.3.2; 5.3.2 of the 2011 edition);

-- Add the measurement of insulation resistance (see 5.3.3);

-- Add the method of measuring the equipment leakage currents, and explain the

relevant contents (see 5.3.4.1);

-- Add some required values (see Table 2).

This document adopts IEC 62353.2014 Medical electrical equipment – Recurrent test

and test after repair of medical electrical equipment by modification.

The technical differences between this document and IEC 62353.2014 and their reasons

are as follows.

-- Use the normatively referenced GB 9706.1 to replace IEC 60601-1.2005 and

IEC 60601-1.2005+AMD 1.2012 to adapt to our country's technical conditions;

-- Use the normatively referenced GB 4793.1 to replace IEC 61010-1 (see Annex

C) to adapt to our country's technical conditions;

-- Use the normatively referenced GB 4793.5 to replace IEC 61010-031 (see

Annex C) to adapt to our country's technical conditions;

-- Use the normatively referenced GB/T 17045 to replace IEC 61140 (see 6.2) to

adapt to our country's technical conditions;

-- Use the normatively referenced GB/T 18216.1 to replace IEC 61557-1 (see

Annex C) to adapt to our country's technical conditions;

-- Use the normatively referenced GB/T 18216.2 to replace IEC 61557-2 (see

Annex C) to adapt to our country's technical conditions;

-- Use the normatively referenced GB/T 18216.4 to replace IEC 61557-4 (see

Annex C) to adapt to our country's technical conditions.

The following editorial changes have also been made to this document.

-- Delete some explanatory content in the Scope and move it to the Introduction;

-- Move the general requirements for testing from the Scope to 4.1;

-- Use the informatively referenced GB/T 5465.2 to replace IEC 60417 (see 3.45,

3.46, 3.47, Annex A);

-- Add some notes.

1 Scope

This document specifies testing of medical electrical equipment and medical electrical

system (hereafter referred to as ME equipment and ME systems) or parts of such

equipment or systems, which comply with GB 9706.1, before putting into service,

during maintenance, during inspection, after repair and in other services, or on occasion

of recurrent tests.

2 Normative references

The following documents, in whole or in part, are normatively referenced in this

document and are indispensable for its application. For dated references, only the

edition cited applies. For undated references, the latest edition of the referenced

document (including any amendments) applies.

GB 4793.1, Safety requirements for electrical equipment for measurement,

control and laboratory use - Part 1.General requirements (GB 4793.1-2007, IEC

61010-1.2001, IDT)

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply.

Some of the definitions are necessarily different from those in GB 9706.1, as

different measuring methods are used.

4 Requirements

The responsible party may omit certain tests based on manufacturers' written

information or accompanying documents.

ME systems shall be visually inspected to determine whether the ME system

configuration is still the same as at the time of the last inspection, or whether any

equipment making up the ME system has been exchanged, added or removed.

5 Tests

For Class I ME equipment, it shall be demonstrated that the protective earth conductor

connects all accessible conductive parts, which may become live in case of a fault, in a

proper and safe way to either the protective earth terminal of the mains plug for

plugged-in equipment or to the protective earth point for permanently installed

equipment.

ME equipment is separated from mains, and the equipment leakage current is measured

according to Figure 6.

6 Results of test and evaluation

The evaluation of safety of ME equipment or ME system shall be performed by

electrically skilled persons (as defined in GB 17045) who have the appropriate training

for testing the equipment under test. If using the measurement equipment listed in

Annex C, measurement uncertainties do not need to be taken into consideration for the

limits.

Annex A

(Informative)

General guidance and rationale

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 50 pages — is available in the English PDF.

Referenced standards

How to Download YY/T 0841-2023

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
50 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0841-2023

$915.00