YY/T 0814-2010Standard test method for evaluating trans-vinylene yield in irradiated ultra-high-molecular-weight polyethylene fabricated forms intended for surgical implants by infrared spectroscopy (English PDF)
红外光谱法评价外科植入物用辐射后超高分子量聚乙烯制品中反式亚乙烯基含量的标准测试方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0814-2010 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
December 27, 2010
Implementation date
June 1, 2012
Scope
YY/T 0814-2010 is the English-translated version of 红外光谱法评价外科植入物用辐射后超高分子量聚乙烯制品中反式亚乙烯基含量的标准测试方法.
YY/T 0814-2010 is the Chinese pharmaceutical industry standard that gives the test method for evaluating the trans-vinylene yield of irradiated ultra-high molecular weight polyethylene in the forms intended for surgical implants, the material being analysed by infrared spectroscopy.
It sets out the specimens, the spectral measurement and the calculation of the yield, which is a measure of the radiation dose the material has absorbed. Issued on 27 December 2010, it applies from 1 June 2012.
Found what you need?
Document preview — YY/T 0814-2010
National Standard of the People's Republic of China
- ICS
- 11.040.40
- Classification
- C 35
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative reference documents
- 3 Terms and definitions
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses the re-drafting method to refer to ASTM F2381-2004 "Infrared Spectroscopy for Evaluating Surgical Implants with Radiation Ultra- Amount of polyethylene products in the trans-vinylidene content of the standard test method "preparation.
The technical differences between this standard and ASTM F2381-2004 are as follows.
--- on the normative reference documents, this standard has made a technical differences in the adjustment to meet China's technical conditions, adjust the situation The situation is reflected in Chapter 2, "Normative references", as follows.
- Replace the ASTM F2102 with YY/T 0772.4.
--- removed Chapter 12 "Keyword";
--- change Appendix X1 to Appendix A, the same.
1 Scope
This test method describes the determination of the number of trans-vinylidene groups in medical implants of ultra-high molecular weight polyethylene (UHMWPE) Method, should use infrared spectroscopy to analyze the material. The test method is based on YY/T 0772.4.
The applicability of IR spectroscopy has been described in other literature reports. This method utilizes CH absorption centered at 1370 cm-1 The thickness of the normalized area of the peak (area) is verified by the inter-laboratory study (ILS) according to ASTM E691.
This standard does not attempt to address all the security issues involved, even those related to its use. Indeed It is the responsibility of the user of this standard to establish appropriate safety and health practices and to apply the limits of management clearly before application.
2 Normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.
YY/T 0772.4 Surgical implants - Ultrahigh molecular weight polyethylene - Part 4. Test method for oxidation index ASTM E691 Guidelines for laboratory test methods for the determination of precision (Practice forconductinganinter-laboratorystudytodetermineprecisionofatestmethod Performance Description and Measurement of ASTM E1421 Fourier Transform Infrared (FT-IR) Spectrometer. Level 0 and Level 1 fordescribingandmeasuringperfomanceoffouriertransforminfrared (FTIR) spectrometers. Level zeroandlevelonetests)
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Trans - vinyleneindex
The ratio of the absorption peak area between 950 cm-1 and 980 cm-1 and the absorption peak area between 1330 cm-1 and 1396 cm-1.
3.2 Positioning depth
depthlocator Measure the average distance from the joint surface or the study surface to the acquisition spectrum and calculate the collection point corresponding to the TVI.
3.3 Trans-vinyleneindexprofile
A pattern in which the transethylene index varies with the distance from the articular surface or the surface of the study surface. The graphic is TVI-DL song
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 0814-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0772.4-2009 — Implants for surgery - Ultra-high-molecular-weight polyethylene - Part 4: Oxidation index measurement method
YY/T 0772.4-2022 — Implants for surgery-Ultra-high-molecular-weight polyethylene - Part 4: Oxidation index measurement method
YY/T 0297-2026 — General requirements for clinical investigation of medical devices
Secure payment via Stripe
Payments accepted
YY/T 0814-2010
$135.00