Valid

YY/T 0813-2010Standard test method for in situ determination of network parameters of crosslinked ultra high molecular weight polyethylene(UHMWPE) (English PDF)

交联超高分子量聚乙烯(UHMWPE)分子网状结构参数的原位测定标准方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0813-2010 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

December 27, 2010

Implementation date

June 1, 2012

Scope

YY/T 0813-2010 is the English-translated version of 交联超高分子量聚乙烯(UHMWPE)分子网状结构参数的原位测定标准方法.

YY/T 0813-2010 is the Chinese pharmaceutical industry standard that gives the test method for determining in situ the network parameters of crosslinked ultra-high molecular weight polyethylene, by measuring the swelling of a specimen immersed in o-xylene.

From that swelling the crosslink density, the molecular weight between crosslinks and the number of repeat units between them are derived, for material crosslinked by ionizing radiation or chemically. Issued on 27 December 2010, it applies from 1 June 2012.

Found what you need?

Document preview — YY/T 0813-2010

National Standard of the People's Republic of China

ICS
11.040.40
Classification
C 35

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

The standard reference method using redrafted ASTM F2214-2002 "crosslinked ultrahigh molecular weight polyethylene (UHMWPE) molecules Mesh In situ determination of structural parameters of the standard method "establishment. Technical differences between this standard and ASTM F2214-2002 follows.

--- Deleted the Chapter 15, "keyword";

--- In Appendix X1 to Appendix A, and Appendix X2 to Appendix B, remains unchanged.

1 Scope

This test method describes how immersion measured in o-xylene ultra high molecular weight polyethylene (hereinafter referred to as UHMWPE)

Swelling of the sample, to ionizing radiation or by chemical crosslinking of UHMWPE crosslink density, molecular weight between cross-linking points and repeating The number of cells was measured. Test techniques and methods of the standard will be used in the above measurement examples will be explained.

This test method is used to measure height changes when UHMWPE samples immersed in o-xylene solvent. The degree of swelling measured volume Suppose a given sample is cross-linked and isotropic dimensional change in all directions are the same. This test method is avoided due to solvent evaporation or temperature change Technology may lead to uncertainty.

This standard does not attempt to all security issues related to the elaborate, even those safety issues associated with their use. Really Li appropriate safety and health practices and regulatory limitations prior to use clear applicability of this standard is the user's own responsibility.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

ASTM D2765 Standard Test Method for Determination of cross-linked polyethylene plastic swelling degree and gel content (Testmethodsfordeter-minationofgelcontentandswelratioofcrosslinkedethyleneplastics) ASTM E691 inter-laboratory test methods to guide precision measurement standards (Practiceforconductinganinter-laboratorystudytodeterminetheprecisionofatestmethod)

3 Terms and Definitions

The following terms and definitions apply to this document.

3.1 Crosslink density

nud The average number of crosslinking points per unit volume of the sample contained theoretically [mol/dm3].

3.2 Molecular weight between crosslinking points

Crosslinking between the theoretical sample point average molecular weight [g/mol].

3.3 The degree of swelling swelratio

Volume ratio of the volume of the sample material does not swell in a swollen equilibrium state.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Normative references

ASTM D2765

Similar standards

How to Download YY/T 0813-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0813-2010

$165.00