Valid

YY/T 0748.1-2009Ultrasonics—Pulse-echo scanner - Part 1: Techniques for calibrating spatial measurement systems and measurement of system point-spread function response (English PDF)

超声脉冲回波扫描仪 第1部分:校准空间测量系统和系统点扩展函数响应测量的技术方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (30 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0748.1-2009 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

November 25, 2009

Implementation date

December 1, 2010

Scope

YY/T 0748.1-2009 is the English-translated version of 超声脉冲回波扫描仪 第1部分:校准空间测量系统和系统点扩展函数响应测量的技术方法.

YY/T 0748.1-2009 is the Chinese pharmaceutical industry standard, identical to IEC 61391-1:2006, that describes how to calibrate the spatial measurement tools of ultrasound pulse-echo scanners and how to measure their point-spread function.

It works in the 0.5 MHz to 15 MHz frequency range and applies to mechanical sector scanners, electronic phased array sector scanners, electronic linear array scanners, electronic convex array sector scanners, water-bath scanners built on these four mechanisms, and reconstruction systems.

The methods rely on test phantoms and on digital analysis of the image, with visual checks also included; normative annexes support the measurements. Manufacturers can use it to state performance specifications, and users to verify that equipment performs to them. Issued on 25 November 2009, it has applied since 1 December 2010.

Found what you need?

Document preview — YY/T 0748.1-2009

National Standard of the People's Republic of China

ICS
11.140.50
Classification
C 41

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions

Foreword

This part of IEC 61391-1:2006 "ultrasonic pulse-echo scanners - Part 1. Techniques for calibrating spatial measurement systems and system point spread function Art method of measuring the number of response "degree of consistency as equivalent.

This section of the Appendix A, Appendix B and Appendix C is a normative appendix.

Terminology Part 3 defined, appear in standard text indicated in bold.

This section is expected to form part of two or more of publication.

--- Part 1 relates to a system for calibrating spatial measurement systems and the point spread function response technology and methods of measurement;

--- Part 2 will involve the system sensitivity, dynamic range and low contrast resolution measurements. This section YY/T Section 10748 of.

This part of the standardization of medical ultrasound equipment for medical appliances National Standardization Technical Committee Technical Committee (SAC/TC10/SC2) Centralized.

This section drafted by. State Food and Drug Administration of Hubei Medical Device Quality Supervision and Inspection Center.

Introduction

Ultrasonic pulse echo scanner with a thin, narrow beam of pulsed ultrasound scanning body region of interest, and received back from the tissue interface Waves, thereby generating ultrasound tissue image within the scan plane. The use of various types of ultrasonic transducers are working in the ultrasonic signal transmitter (pick Closed) mode. In medical practice, the widespread use of ultrasound scanner for many soft tissues and organs in the human body for imaging.

Test methods described in this section has been widely recognized and for all types of devices. Manufacturers can use this part of the party Method to develop technical performance specifications of their products, the user can use this standard method to test the performance of these technologies, these measurements are not available in Movies Under loud instrument working normally, in the appendix describes the typical phantom. The structure of the phantom is not detailed provisions, but describes The structure of the specific modes to be announced together with the type of application and the internal structure of the overall test results and test. The phantom has a similar s product.

Performance parameters and select the corresponding measurements provided for manufacturer's technical requirements and expected the same of diagnostic applications, in different Comparison provides a basis for similar types of manufacturers of devices. The results by the standard tests used to obtain permits than Than the manufacturer's specifications, and is expected to recommend the use of set of results and data obtained by the method, it is determined whether the device is suitable for performance diagnosis When broken applications, it will provide a useful criterion. This section focuses on the image measured by digital technology, but also includes for through Through the visual inspection method. Discuss other visual inspection methods can be found in the way YY/T 0703-2008 (IEC 61390:1996, IDT) 1).

1) Figures in square brackets for the reference number.

Diagnostic system has more than one specific system optional components, such as when the ultrasonic transducers, each identified option constitutes a separate system. If, however, the majority of meaningful machine control settings and accessories were tested, it is considered fully evaluated sex machine can. Of course, the device can further evaluation, but wish to use as a case rather than the conventional requirement.

1 Scope

YY/T 0748 provisions of this section within the 0.5MHz ~ 15MHz ultrasonic frequency range, the calibration space measurement tools and ultrasound imaging The method of the point spread function of the device, this section covers the following types based on the principle of ultrasonic echo ultrasound scanner.

--- Mechanical sector scanner;

--- Electronic phased array sector scanner;

--- Electronic linear array scanner;

--- Electronic convex array sector scanner;

--- Based on the above four scanning mechanism bladders scanner;

--- Reconstruction system.

2 Normative references

The following documents contain provisions which, through reference YY/T 0748 and become part of the provisions of this section. For dated references, All subsequent amendments (not including errata content) or revisions do not apply to this section, however, encourage the agreement on this section Whether the parties can study the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

GB/T 16540-1996 acoustic characterization of ultrasonic fields in the frequency range of 0.5MHz ~ 15MHz and measuring hydrophone Control law (eqv IEC 61102:1991)

YY/T 0458-2003 simulated Doppler blood flow phantom technical requirements (IEC 61685:2001, MOD)

3 Terms and Definitions

The following terms and definitions apply YY/T 0748 to the present section.

3.1 A-scan

Data acquisition type one-dimensional mode, collecting echo information from a single point in the axis of the ultrasonic beam. Echo amplitude information With respect to the propagation time or distance displayed.

3.2 Acoustic coupling medium

A material is typically a gel or other liquid, to ensure between the transducer and the skin of the patient, or the transducer and the sealing surface of the phantom Acoustic contiguity.

3.4 Automatic time-gain compensation

Automatic working time gain compensation, based on the depth of the ultrasonic pulse amplitude decay associated with the observed decrease in the amplitude of the echo is based.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 30 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 0748.1-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
30 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0748.1-2009

$465.00