Valid

YY/T 0744-2009Particular specifications for mobile C-arm X-ray equipment (English PDF)

移动式C形臂X射线机专用技术条件

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0744-2009 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

November 25, 2009

Implementation date

December 1, 2010

Scope

YY/T 0744-2009 is the English-translated version of 移动式C形臂X射线机专用技术条件.

YY/T 0744-2009 is the Chinese standard "Particular specifications for mobile C-arm X-ray equipment". Its scope clause reads: This standard specifies classification and composition as well as requirements and test methods for mobile C-arm X-ray equipment (hereinafter referred to as C-arm X-ray equipment).

This standard is applicable to the X-ray equipment equipped with mobile C-arm mechanical support device and this product is mainly used for the positioning and inspection by medical institutes in the surgery. Its clauses include terms and definitions; classification and composition.

Found what you need?

Document preview — YY/T 0744-2009

National Standard of the People's Republic of China

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • 1 Scope
  • 2 Normative References
  • 3 Terms and Definitions
  • 4 Classification and Composition
  • 5 Requirements
  • 6 Test Methods

1 Scope

This standard specifies classification and composition as well as requirements and test methods for mobile C-arm X-ray equipment (hereinafter referred to as C-arm X-ray equipment).

This standard is applicable to the X-ray equipment equipped with mobile C-arm mechanical support device and this product is mainly used for the positioning and inspection by medical institutes in the surgery.

2 Normative References

The following standards contain provisions which, through reference in this text, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards. For undated references, the latest edition of the normative document referred to applies.

GB 9706.1-2007 Medical Electrical Equipment - Part 1: General Requirements for Safety (IEC 60601-1: 1988, IDT)

GB 9706.3-2000 Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of High-voltage Generators of Diagnostic X-ray Generators (idt IEC 60601-2-7: 1998)

GB 9706.11-1997 Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of X-ray Source Assemblies and X-ray Tube Assemblies for Medical Diagnosis (idt IEC 60601-2-28: 1993)

GB 9706.12-1997 Medical Electrical Equipment - Part 1: General Requirements for Safety 3. Collateral Standard: General Requirements for Radiation Protection in Diagnostic X-ray equipment (idt IEC 60601-1-3: 1994)

GB 9706.14-1997 Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Associated Equipment of X-ray Equipment (idt IEC 60601-2-32: 1994)

GB 9706.15-2008 Medical Electrical Equipment - Part 1: General Requirements for Safety - 1. Collateral Standard: Safety Requirements for Medical Electrical Systems (IEC 60601-1-1: 2000, IDT)

GB/T 10149 Terminology and Symbol for Medical X-ray Equipment

GB/T 10151-2008 Medical Diagnostic X-ray Equipment - Specifications for High Voltage Cable Plugs and Sockets

GB/T 19042.1-2008 Evaluation and Routine Testing in Medical Imaging Departments - Part 3-1: Acceptance Tests - Imaging Performance of X-ray Equipment for Radiography and Radioscopic Systems (IEC 61223-3-1: 1999, IDT)

GB/T 19042.3-2005 Evaluation and Routine Testing in Medical Imaging Departments - Part3-3: Acceptance Tests - Imaging Performance of X-ray Equipment for Digital Subtraction Angiography (DSA) (IEC 61223-3-3: 1996, IDT)

YY 0076-1992 Coating Classifications for Metal Product - Technical Conditions

YY/T 0106-2008 General Specifications for Medical Diagnostic X-ray Equipment

YY/T 0291-2007 The Environmental Requirements and Test Methods for Medical X-ray Equipment

YY 0605-2005 Medical Electrical Equipment - Part 1-2: General Requirements for Safety - Collateral Standards: Electromagnetic Compatibility Requirements and Tests (IEC 60601-1-2: 2001, IDT)

3 Terms and Definitions

For the purpose of this standard, the terms and definitions established in GB/T 10149, GB/T 19042.1-2003 and GB/T 19042.3-2005 apply.

4 Classification and Composition

4.1 Classification

According to the classification by product structure, it belongs to the mobile equipment.

4.2 Composition

C-arm X-ray equipment shall be composed of X ray generator system, mobile C-arm support frame and X-ray image system at least.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download YY/T 0744-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0744-2009

$179.00