Scope

YY/T 0707-2008 is the English-translated version of 移动式摄影X射线机专用技术条件.

YY/T 0707-2008 is the Chinese standard "Particular specifications for mobile radiography X-ray equipment". Its scope clause reads: This standard specifies terms, classification and composition, requirements as well as test methods for the mobile radiography X-ray equipment (hereinafter referred to as X-ray equipment).

This standard is only applicable to X-ray equipment for special photography function powered by single phase A.C. power supply and/or internal power supply. Its clauses include terms and definitions; classification and composition; requirements.

Found what you need?

Document preview — YY/T 0707-2008

National Standard of the People's Republic of China

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • 1 Scope
  • 2 Normative References
  • 3 Terms and Definitions
  • 4 Classification and Composition
  • 5 Requirements
  • 6 Test Methods

1 Scope

This standard specifies terms, classification and composition, requirements as well as test methods for the mobile radiography X-ray equipment (hereinafter referred to as X-ray equipment).

This standard is only applicable to X-ray equipment for special photography function powered by single phase A.C. power supply and/or internal power supply.

2 Normative References

The following documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments to (excluding amending error in the text), or revisions of, any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to study whether the latest edition of these documents is applicable. For undated references, the latest edition of the normative document is applicable to this standard.

GB 5579 High-voltage Cable Plug and Socket Connections for Medical X-ray Equipment

GB 9706.1-2007 Medical Electrical Equipment - Part 1: General Requirements for Safety (IEC 60601-1: 1988, IDT)

GB 9706.3-2000 Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of High-voltage Generators of Diagnostic X-ray Generators (idt IEC 60601-2-7: 1998)

GB 9706.11-1997 Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of X-ray Source Assemblies and X-ray Tube Assemblies for Medical Diagnosis (idt IEC 60601-2-28: 1993)

GB 9706.12-1997 Medical Electrical Equipment - Part 1: General Requirements for Safety 3. Collateral Standard: General Requirements for Radiation Protection in Diagnostic X-ray equipment (idt IEC 60601-1-3: 1994)

GB 9706.14-1997 Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Associated Equipment of X-ray Equipment (idt IEC 60601-2-32: 1994)

GB/T 10149 Terminology and Symbol for Medical X-ray Equipment

GB/T 19042.1-2003 Evaluation and Routine Testing in Medical Imaging Departments - Part 3-1: Acceptance Tests - Imaging Performance of X-ray equipment for Radiographic and Radioscopic systems (IEC 61223-3-1: 1999, IDT)

YY 0505-2005 Medical Electrical Equipment - Part 1-2: General Requirements for Safety - Collateral Standards: Electromagnetic Compatibility Requirements and Tests (IEC 60601-1-2: 2001, IDT)

YY 0076-1992 Coating Classifications for Metal Product - Technical Conditions

YY/T 0291-2007 The Environmental Requirements and Test Methods for Medical X-ray Equipment

3 Terms and Definitions

For the purpose of this standard, the terms and definitions in the GB/T 10149 apply.

4 Classification and Composition

4.1 Classification

The safety classification shall be in accordance with those specified in GB 9706.1-2007.

4.2 Composition

X-ray equipment at least shall be equipped with the following main components:

a) X ray generator system;

b) Mechanical support device.

5 Requirements

5.1 Operating conditions

5.1.1 Environment conditions

Unless otherwise specified, the operating environment of X-ray equipment shall meet the following conditions:

a) Environment temperature: 10°C~40°C;

b) Relative humidity: 30%~75%;

c) Atmospheric pressure: 700hPa ~1060hPa.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download YY/T 0707-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0707-2008

$115.00