YY/T 0681.9-2011Test methods for sterile medical device package - Part 9: Burst testing of flexible package seals using internal air pressurization weight restraining plates (English PDF)
无菌医疗器械包装试验方法 第9部分:约束板内部气压法软包装密封胀破试验
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0681.9-2011 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
December 31, 2011
Implementation date
June 1, 2013
Scope
YY/T 0681.9-2011 is the English-translated version of 无菌医疗器械包装试验方法 第9部分:约束板内部气压法软包装密封胀破试验.
YY/T 0681.9-2011 is the Chinese pharmaceutical industry standard that gives the burst test for the seals of a flexible package, the package being restrained between weighted plates while it is pressurised internally with air, so that the minimum bursting strength of its peripheral seal is determined.
It is the ninth part of the YY/T 0681 series and sets out the apparatus, the rate of pressurisation and the way the result is recorded. Issued on 31 December 2011, it has applied since 1 June 2013.
Found what you need?
Document preview — YY/T 0681.9-2011
National Standard of the People's Republic of China
- Classification
- C 31
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Summary of Test Method
Foreword
YY/T 0681 "sterile medical devices packaging materials, test methods", consists of the following components.
--- Part 1. accelerated aging test guidelines;
--- Part 2. sealing strength flexible barrier material;
--- Part 3. Unconstrained pressure within the package of anti-sabotage;
--- Part 4. Determination of staining solution penetrate breathable packaging seal leakage;
--- Part 5. coarse leak was detected internal pressure (bubble method);
--- Part 6. flexible packaging material and ink coating chemical resistance evaluation;
--- Part 7. Evaluation of flexible packaging material with adhesive tape or coating ink fastness;
--- Part 8. coating layer weight determination;
--- Part 9. constraint plate internal pressure bursting test method flexible seal;
--- Part 10. Classification breathable packaging material and microbial tests. This section YY/T Section 90681 of. This section drafted in accordance with GB/T 1.1-2009 given rules.
YY/T 0681 Part revised adoption ASTM F2054-00 "constraint-board internal pressure bursting test method flexible sealing methods."
This part of the National Technical Committee of Standardization for medical infusion set (SAC/TC106) centralized.
This section is drafted. Shandong Medical Devices Product Quality Inspection Center, Ltd. Shandong Xinhua.
Drafters of this section. Cheng Yu Qian, Zhang Jing, in Xiaohui, Zhong Wenquan.
1 Scope
Test methods YY/T 0681 provisions of this section, the provisions of the flexible plate is disposed within the constraints of internal pressure to test its periphery The minimum bursting strength of a seal.
This test applies only to the periphery of the flexible seal (usually a combination of the bag). Especially for its peelable seal has characterized (by the end Remove the peel after a user contents) packaging.
This method is recommended for users to pay special attention may be required to design and production constraints board fixture. About stress factors and structural design considerations See Informative Annex C.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
YY/T 0681.2 Test methods for packaging sterile medical devices - Part 2.
YY/T 0681.3 Test methods for packaging sterile medical devices - Part 3. Unconstrained pressure within the package of anti-sabotage
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1 Or a combination of flexible packaging bags
flexiblepackage Sealing the packaging material on at least one flexible packaging structure (e.g., paper, polyethylene, etc.).
3.2 Constraints board restrainingplates
When the package to be made into pressure contact with the surface of the packaging and rigid panels restrict expansion.
4 Summary of Test Method
4.1 on a single instrument for the test pressure inside the package is filled until the packing breakage. In most cases rupture occurred in a sealed area or Several. Inflatable and pressure equipment requirements increase to maintain the internal pressure before the seal is broken. In the pressurization process, the packaging should be placed in two Between rigid parallel plates (plate bound), to limit the expansion and deformation of the packaging, but so that the sealing surrounding area unconstrained. An insert inside the package A sensor for detecting the internal pressure of the package rupture. Depending on the application, this test method requires the use of two configurations restricting plate, described as follows.
4.1.1 opening packaging configurations. three for the peripheral seal, the fourth side open packaging. This configuration is commonly used in the production of preformed packaging. Configuration uses described in Figure 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download YY/T 0681.9-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY/T 0681.2-2010 — Test methods for sterile medical device package - Part 2: Seal strength of flexible barrier materials
YY/T 0681.3-2010 — Test methods for sterile medical device package - Part 3: Internal pressurization failure resistance of unrestrained packages
YY/T 0681.10-2011 — Test methods for sterile medical device package - Part 10: Test for microbial barrier ranking of porous package material
Secure payment via Stripe