YY/T 0616.2-2016Medical glove for single use - Part 2: Requirements and testing for shelf life determination (English PDF)
一次性使用医用手套 第2部分:测定货架寿命的要求和试验
This is a limited preview
Buy now to download the full PDF (22 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0616.2-2016 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
January 26, 2016
Implementation date
January 1, 2017
Scope
YY/T 0616.2-2016 is the English-translated version of 一次性使用医用手套 第2部分:测定货架寿命的要求和试验.
YY/T 0616.2-2016 is the Chinese pharmaceutical industry standard that sets the requirements for determining and stating the shelf life of single-use medical gloves, together with the labelling and the disclosure of the test methods used.
It is the second part of the YY/T 0616 series and applies to existing products, to new ones and to designs that have changed significantly, and it explains what is expected where an existing design has no ageing data of its own. Issued on 26 January 2016, it has applied since 1 January 2017.
Found what you need?
Document preview — YY/T 0616.2-2016
National Standard of the People's Republic of China
- ICS
- 11.140
- Classification
- C 48
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative reference documents
- 3 Terms and definitions
Foreword
YY/T 0616 "One-time use of medical gloves" is divided into two parts.
- Part 1. Biology evaluation requirements and testing;
- Part 2. Requirements and tests for determining shelf life. This part is part 2 of YY/T 0616.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This section refers to EN 455-4.:2009 "Disposable medical gloves Part 4. Requirements and tests for determining shelf life".
Introduction
Medical gloves are expected to be used as a barrier to infection. To ensure its effectiveness, the gloves are necessary for hand, impermeable and adequate Of the physical strength, so that it does not occur in the use of failure. The national standard for medical gloves 1) gives these requirements.
This standard requires manufacturers to conduct stability tests prior to product launch to estimate the shelf life of any new or technically improved gloves Life, and at the same time the actual time stability study. The actual time stability test can be seen as requiring the manufacturer to supervise the post-market product The contents of the governor. These requirements are expected to ensure that the manufacturer has sufficient data to support the declaration of the shelf life of its products before listing Submitted to the regulatory body for review.
1) These standards include GB 7543, GB 10213, GB 24786 and GB 24787 and so on.
1 Scope
YY/T 0616 this part of the provisions of the disposable use of gloves shelf life requirements. Also specify the label and the test used Method related to the disclosure of information requirements.
This section applies to existing, new and designed products with significant changes. It is reasonable to have an existing design that does not have available aging data Of the time period to produce data.
This section does not specify the bulk size. Need to pay attention to the bulk of the difficulties in circulation and control. The maximum number of recommended production batches The amount of 500000.
2 Normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 19633 (all parts) final sterilization of medical equipment packaging
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Arrhenius formula Arrheniusequation
Activation energy (EA), absolute temperature (T) and degradation rate constant [k (T)].
Note. The life of the shelf life of the rubber product is based on the Arrhenius principle of the chemical reaction rate. The Arrhenius formula has the following basic form. -EA Where. A - constant in minutes per minute (min-1); EA - activation energy in joules per mole (J/mol); R - General gas constant (8.314J · mol-1 · K-1);
T --- absolute temperature, the unit is Kelvin (K); k (T) - the rate constant of the degradation process, in minutes per minute (min-1).
Another form of expression of the Arrhenius formula is. lnk (T) = lnA- RT ()
The time required for the physical performance to fall below the threshold is inversely proportional to the rate constant k (T).
3.2 Sales package
Is expected to flow to the consumer, with multiple gloves or a pair of gloves packaging.
Note. For example, the initial packaging (peeled packaging) of the sterile product or the dispensing box of the non-sterile product.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 22 pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 19633
Similar standards
How to Download YY/T 0616.2-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 19633.1-2024 — Packaging for terminally sterilized medical devices - Part 1: Requirements for materials, sterile barrier systems and packaging systems
GB/T 19633.2-2024 — Packaging for terminally sterilized medical devices - Part 2: Validation requirements for forming, sealing and assembly processes
YY/T 0616.1-2016 — Medical gloves for single use - Part 1: Requirements and testing for biological evaluation