Valid

YY/T 0616.4-2018Medical glove for single use - Part 4: Test method for the puncturation resistance (English PDF)

一次性使用医用手套 第4部分:抗穿刺试验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (20 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0616.4-2018 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

December 20, 2018

Implementation date

January 1, 2020

Scope

YY/T 0616.4-2018 is the English-translated version of 一次性使用医用手套 第4部分:抗穿刺试验方法.

YY/T 0616.4-2018 is the Chinese pharmaceutical industry standard that gives the test for the puncture resistance of single-use medical gloves. It is the fourth part of the YY/T 0616 series and sets the test conditions, the procedure and the reporting: the probe and its geometry, the rate of penetration and the force recorded at puncture.

The method judges resistance to blunt puncture and is not designed to assess resistance to a sharp device such as a hypodermic needle. Issued on 20 December 2018, it has applied since 1 January 2020.

Found what you need?

Document preview — YY/T 0616.4-2018

National Standard of the People's Republic of China

ICS
11.140
Classification
C 48

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Instruments

Foreword

YY/T 0616 "Disposable Medical Gloves" consists of the following.

--- Part 1. Biological evaluation requirements and tests;

--- Part 2. Determination of shelf life requirements and tests;

--- Part 3. Method for determining the actual time lapse date by using finished gloves in storage;

--- Part 4. Anti-puncture test method. This part is the fourth part of YY/T 0616.

This part is drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This part of YY/T 0616 specifies the test conditions, test procedures and results report for the puncture resistance of disposable medical gloves.

This section applies to the evaluation of the puncture resistance of disposable medical gloves.

Note. The method given in this section is not designed to evaluate the ability of an anti-sharp device (such as an injection needle) to puncture.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 2941 Rubber Physical Testing Methods General Procedures for Sample Preparation and Regulation

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Puncture resistance

The ability of a medical glove to resist puncture is characterized by the force required to puncture the sample.

3.2 Puncture displacement

The displacement produced by the puncture device starting to contact the sample to puncture the sample.

4 Instruments

4.1 Thickness Gauge

The thickness gauge conforming to GB/T 2941 has an accuracy of 0.01 mm and is used to determine the thickness of the medical glove sample.

4.2 Testing machine

The following conditions should be met.

a) The specimen should be firmly fixed and the two clamps can move at a uniform rate;

b) capable of collecting data on the load as a function of displacement until the sample is punctured;

c) the error of the machine within its load range should not exceed ± 2%;

d) The compression unit should be configured. The compression unit of the test machine shall be capable of being connected to the upper and lower arms of the test machine. The compression unit should have enough To penetrate the moving range of the sample.

4.3 Puncture device

4.3.1 The piercer should be manufactured to the dimensions shown in Figure 1. The puncturing device should be made of stainless steel with a Rockwell hardness of not less than 35.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download YY/T 0616.4-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
20 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0616.4-2018

$105.00