YY/T 0286.5-2021Special infusion sets - Part 5: Bottle-type and bag-type infusion sets for single use (English PDF)
专用输液器 第5部分:一次性使用吊瓶式和袋式输液器
This is a limited preview
Buy now to download the full PDF (25 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0286.5-2021 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
March 9, 2021
Implementation date
April 1, 2022
Scope
YY/T 0286.5-2021 is the English-translated version of 专用输液器 第5部分:一次性使用吊瓶式和袋式输液器.
YY/T 0286.5-2021 is the Chinese standard "Special infusion sets - Part 5: Bottle-type and bag-type infusion sets for single use". Its scope clause reads: This part of YY/T 0286 stipulates that the liquid storage container is not larger than 500mL, and the disposable bottle is mainly used for liquid infusion.
Type and bag type infusion set (hereinafter referred to as bottle type and bag type infusion set) to ensure that it is compatible with infusion containers and intravenous devices.
This section applies to bottle-type and bag-type infusion sets whose liquid storage container is not larger than 500mL and whose main purpose is to divide liquid infusion.
This section does not apply to burette infusion sets that require precise control of the infusion dose. Its clauses include general requirements.
Found what you need?
Document preview — YY/T 0286.5-2021
National Standard of the People's Republic of China
- Classification
- C 31
- Replacing
- YY 0286.5-2008
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 General requirements
1 Scope
This part of YY/T 0286 stipulates that the liquid storage container is not larger than 500mL, and the disposable bottle is mainly used for liquid infusion.
Type and bag type infusion set (hereinafter referred to as bottle type and bag type infusion set) to ensure that it is compatible with infusion containers and intravenous devices.
This section applies to bottle-type and bag-type infusion sets whose liquid storage container is not larger than 500mL and whose main purpose is to divide liquid infusion.
This section does not apply to burette infusion sets that require precise control of the infusion dose.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article
Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document.
GB/T 6682 Analytical laboratory water specifications and test methods
GB 8368 Gravity infusion type disposable infusion set
GB/T 14233.1-2008 Medical transfusion, blood transfusion, injection equipment inspection methods Part 1.Chemical analysis methods
GB 15811 Sterile injection needle for single use
3 General requirements
3.1
Typical hanging bottle and bag type infusion set components and their terms are shown in Figure 1.
Note. Figure 1 shows the configuration of a typical bottle/bag infusion set, if it can play the same role, other configurations can also be used.
3.2
Bottle-type and bag-type infusion sets should have a protective cover to keep their interior sterile before use.
3.3
If a separate intake device is used, the intake device should comply with GB 8368.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 6682Water for analytical laboratory use - Specification and test methods
- GB 8368Infusion sets for single use -- Gravity feed
- GB/T 14233.1-2008Test methods for infusion, transfusion, injection equipments for medical use - Part 1: Chemical analysis methods
- GB 15811Sterile hypodermic needles for single use
Similar standards
Editions of YY/T 0286.5
| Edition | Title | Revision | Status |
|---|---|---|---|
| YY/T 0286.5-2021 | Special infusion sets - Part 5: Bottle-type and bag-type infusion sets for single use | current edition | Current |
| YY 0286.5-2008 | Special infusion sets - Part 5: Bottle-type and bag-type infusion sets for single use | previous edition | Superseded |
This page sells the current edition, YY/T 0286.5-2021. Earlier editions are listed for reference only.
How to Download YY/T 0286.5-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 15811-2016 — Sterile hypodermic needles for single use
GB 15811-2025 — Sterile hypodermic needles for single use
GB 8368-2018 — Infusion sets for single use -- Gravity feed
Secure payment via Stripe
Payments accepted
YY/T 0286.5-2021
$150.00