YY/T 0127.5-2014Biological evaluation of medical devices used in dentistry - Part 5: Inhalation toxicity test (English PDF)
口腔医疗器械生物学评价 第5部分:吸入毒性试验
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for YY/T 0127.5-2014 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Recommended
Issue date
June 17, 2014
Implementation date
July 1, 2015
Scope
YY/T 0127.5-2014 is the English-translated version of 口腔医疗器械生物学评价 第5部分:吸入毒性试验.
YY/T 0127.5-2014 is the Chinese pharmaceutical industry standard that gives the inhalation toxicity test for the medical devices used in dentistry.
It is the fifth part of the YY/T 0127 series and applies to a device or a component of one that is markedly volatile at room temperature or under its conditions of use, setting out the animals, the exposure chamber and the concentration of the vapour, the duration of the exposure, the observations made during and after it and the interpretation of the result. Issued on 17 June 2014, it has applied since 1 July 2015.
Found what you need?
Document preview — YY/T 0127.5-2014
National Standard of the People's Republic of China
- ICS
- 11.060.10
- Classification
- C 33
- Replacing
- YY/T 0127.5-1999
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Appliances and equipment
Foreword
This section is "Oral Biological evaluation of medical devices" series standard part of the standard.
YY/T 0268 "Dentistry Oral Biological evaluation of medical devices Module 1. Evaluation and testing" oral biology Medical Devices Evaluation of the pilot project selection criteria as a guide.
YY/T 0127 and YY/T 0244 "Test methods for dental materials biological short-term systemic toxicity test. the oral route" oral health Device specific biological test method standards, where YY/T 0127 is divided into the following sections.
--- YY/T 0127.1 Test methods for dental materials biological hemolysis test;
--- YY/T 0127.2 Biological evaluation of medical devices oral Unit 2. Test methods for acute systemic toxicity test. Intravenous way;
--- YY/T 0127.3 Dental Materials and biological test methods - Part 3. Application Test of the root canal;
--- YY/T 0127.4 Test methods for dental materials Biology Unit 2. Biological test methods of dental materials Bone implants trials;
--- YY/T 0127.5 Oral Biological evaluation of medical devices - Part 5. Biological test methods of dental materials inhalation toxicity test;
--- YY/T 0127.6 Biological Evaluation of Dental Materials Unit 2. Biological test methods of dental materials dominant lethal test;
--- YY/T 0127.7 Biological Evaluation of Dental Materials Unit 2. Biological test methods of dental materials Pulp and dentine usage test;
Biological Evaluation --- YY/T 0127.8 Dental Materials Unit 2. Biological test methods of dental materials subcutaneous implantation test;
--- YY/T 0127.9 Biological Evaluation of Dental Materials Unit 2. Biological test methods of dental materials cytotoxicity test. Joan Fat cover method and molecular filtration method;
--- YY/T 0127.10 Biological evaluation of medical devices oral Unit 2. Test methods for Salmonella typhimurium reply projections Variable test (Ames test);
--- YY/T 0127.11 dentistry for preclinical evaluation of biocompatibility of medical devices oral Unit 2. Dental Materials Biological test methods of pulp capping test;
--- YY/T 0127.12 Dentistry Oral Biological evaluation of medical devices Module 2. Test methods micronucleus test;
--- YY/T 0127.13 Biological evaluation of medical devices oral Unit 2. Test methods oral mucosa irritation test;
--- YY/T 0127.14 Oral Biological evaluation of medical devices Unit 2. Test methods for acute oral systemic toxicity tests;
--- YY/T 0127.15 Biological evaluation of medical devices oral Unit 2. Test methods subacute and subchronic systemic toxicity Test the oral route;
--- YY/T 0127.16 Oral Biological evaluation of medical devices Unit 2. Test methods for mammalian cells in vitro chromosomal Aberration test;
--- YY/T 0127.17 Oral Biological evaluation of medical devices - Part 17. mouse lymphoma cells (TK) gene mutation test. This section YY/T Section 50127 of. This section drafted in accordance with GB/T 1.1-2009 given rules.
This section instead of YY/T 0127.5-1999 "Biological Evaluation of Dental Materials Unit 2. Test methods for inhalation toxicity testing." With YY/T 0127.5-1999 following major technical changes, these changes are based on OECD436.2009 and OECD 403.2008 in which the content.
--- Modify the acute inhalation toxicity of definition, "in the short term (24h or less than 24h)" read "in the short term (4h ~ 6h);
--- Remove the "median lethal dose LD50", "lethal concentration LC50", the definition of "dynamic exposure device";
--- Increased "concentration", "a finite concentration", the definition of "limit test";
--- Chapter 5, "experimental animals," added "animal welfare" of the content;
--- Added "static body inhalation device" in exposure mode selection;
--- In the "dynamic systemic inhalation device," added gas mixing device, shown in Figure 2, 5;
--- The exposure time is usually defined as rats 6h, mice typically 4h;
--- To increase the content of "limit test and the main test", delete the words "maximum tolerated dose trial";
--- The number of test animals from "n = 10" to "n = 6";
--- After the test period was observed from the "7d" to "14d";
--- Results of the evaluation, the LC50 no longer as criteria, but at a dose level of ">=5000mg/m³ test, whether an animal Obvious symptoms of poisoning or death "as the criteria;
1 Scope
YY/T 0127 This section provides oral inhalation toxicity testing of medical devices.
This section applies to the evaluation at room temperature or inhalation toxicity has significant volatility oral medical devices or components thereof under application conditions.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 16886.2 Biological evaluation of medical devices - Part 2. Animal welfare requirements
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1 Acute inhalation toxicity
In the short period of time (4h ~ 6h), a continuous suction side effects after the test substance is caused.
3.2 Concentration
Mass per unit volume of air being test substance (mg/L, mg/m3).
3.3 Limit concentration
The maximum concentration of inhalation toxicity test requirements, the test substance is determined by the physical state. When using GSH classification system, steam limit Given concentration of 20000mg/m³, or the test substance reach the maximum possible concentration.
3.4 Limit test
Single animals inhaled a clear concentration of test substance is completed inhalation toxicity tests.
3.5 Median lethal time
medianlethaltime; LT50 Overall a substance in the test animals, causing 50% of the time the animals died.
4 Appliances and equipment
4.2 Analytical balance. Indexing is 0.0001g.
4.1 Flowmeter. LF meter 100L/h, 200L/h, 4% accuracy
4.3 GC
4.4 Static exposure apparatus
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of YY/T 0127.5
| Edition | Title | Revision | Status |
|---|---|---|---|
| YY/T 0127.5-2014 | Biological evaluation of medical devices used in dentistry - Part 5: Inhalation toxicity test | current edition | Current |
| YY/T 0127.5-1999 | Biological evaluation of medical devices used in dentistry - Part 5: Inhalation toxicity test | previous edition | Superseded |
This page sells the current edition, YY/T 0127.5-2014. Earlier editions are listed for reference only.
How to Download YY/T 0127.5-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16886.2-2011 — Biological evaluation of medical devices -- Part 2: Animal welfare requirements
GB/T 16886.2-2026 — Biological evaluation of medical devices - Part 2: Animal welfare requirements
YY/T 0127.6-1999 — Biological evaluation of dental materials - Unit 2: Biological test methods of dental materials - Dominant lethal test
Secure payment via Stripe
Payments accepted
YY/T 0127.5-2014
$145.00