Valid

YY 1412-2016Cardiopulmonary bypass systems - Centrifugal pump (English PDF)

心肺转流系统 离心泵

Open the YY 1412-2016 preview as PDF

Preview — first pages of YY 1412-2016 (full document: 17 pages)

This is a limited preview

Buy now to download the full PDF (17 pages)

Issued by

NMPA

Level / Type

Industry · Mandatory

Issue date

March 23, 2016

Implementation date

January 1, 2018

Scope

YY 1412-2016 is the English-translated version of 心肺转流系统 离心泵.

YY 1412 is the mandatory Chinese standard for the centrifugal pumps used in cardiopulmonary bypass and ECMO, the pump heads that move a patient's entire circulation while the heart is stopped or supported. It sets the requirements such a pump has to meet and the test methods that verify them, covering the flow it delivers against pressure, the haemolysis it causes as blood passes through it, the seal and bearing integrity over hours or days of continuous running, the coupling to the drive and the behaviour if drive is lost. Centrifugal pumps replaced roller pumps for long runs precisely because they damage blood less, so haemolysis is the measurement that justifies the design. Being a YY standard without the /T suffix, compliance is compulsory in China.

Document preview — YY 1412-2016

National Standard of the People's Republic of China

ICS
11.040.40
Classification
C45

Issued by: National Medical Products Administration

Contents

  • 1 Scope
  • 2 Normative reference documents
  • 3 Terms and definitions
  • 4.1 Classification

Foreword

The technical content of this standard is mandatory. This standard is drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuer of this document does not assume responsibility for the identification of these patents. This standard is proposed by the State Food and Drug Administration. This standard is defined by the National Standard Committee on Medical Extracorporeal Circulation Equipment (SAC/TC158) and is responsible for the interpretation. The drafting unit. the State Food and Drug Administration Guangzhou Medical Device Quality Supervision and Inspection Center, Maike Wei (Shanghai) Medical Equipment Limited. The main drafters of this standard. Li Shi, Wang Ping, Fan Xiang, Li Aijun, Gu Xiaowei. Cardiopulmonary bypass system centrifugal pump

1 Scope

YY 1412 is the mandatory Chinese standard for the centrifugal pumps used in cardiopulmonary bypass and ECMO, the pump heads that move a patient's entire circulation while the heart is stopped or supported. It sets the requirements such a pump has to meet and the test methods that verify them, covering the flow it delivers against pressure, the haemolysis it causes as blood passes through it, the seal and bearing integrity over hours or days of continuous running, the coupling to the drive and the behaviour if drive is lost. Centrifugal pumps replaced roller pumps for long runs precisely because they damage blood less, so haemolysis is the measurement that justifies the design. Being a YY standard without the /T suffix, compliance is compulsory in China.

This standard specifies the terminology and definition, classification, composition, parameters, requirements, test methods, signs, and use of CPR centrifugal pumps. Brochures, packaging, transportation, storage. This standard applies to cardiopulmonary bypass system centrifugal pump (hereinafter referred to as centrifugal pump). The centrifugal pump for medical units for surgery and rescue, For cardiopulmonary bypass and extracorporeal membrane oxygenation surgery in the blood perfusion or local perfusion, can be used independently and/or supporting the use of artificial heart-lung machine. This standard does not apply.

--- Roller pump; - extracorporeal circulation;

--- gas filter; Attract the pump

--- centrifugal pump head.

2 Normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document.

GB/T 191 packaging and storage icon Medical electrical equipment - Part 1. General requirements for safety

GB 9706.1 General rules for the use of industrial products

GB/T 9969 Environmental requirements and test methods for medical appliances GB/T 14710-2009

YY/T 0466.1 Symbols for medical devices for labeling, labeling and providing information on medical devices - Part 1. General requirements

YY/T 1145 Artificial heart - lung machine terminology

3 Terms and definitions

YY/T 1145 and the following terms and definitions apply to this document.

3.1 Centrifugal pump pump head centrifugalpump-head Centrifugal centrifugal force centrifugal force of the disposable perfusion device. 4 classification, composition, parameters

4.1 Classification

4.1.1 according to the different ways of blood flow are divided into. centrifugal constant flow, centrifugal pulsating.

4.1.2 According to the maximum speed is divided into.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

Similar standards

YY/T 1561|YY 1271|YY 1290|YY/T 1414|YY 1413

How to Buy YY 1412-2016

  1. 1Add to cart. Click the "Buy YY 1412-2016" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY 1412-2016

$150.00

$130.00for partners