YY 0875-2013Linear stapler and cartridge (English PDF)
直线型吻合器及组件
This is a limited preview
Buy now to download the full PDF (16 pages)
Need quotation for your management?
Get a formal quotation for YY 0875-2013 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Mandatory
Issue date
October 21, 2013
Implementation date
October 1, 2014
Scope
YY 0875-2013 is the English-translated version of 直线型吻合器及组件.
YY 0875-2013 is the Chinese pharmaceutical industry standard covering linear stapler and cartridge. It was issued on 21 October 2013 and has been in force since 1 October 2014, as a first edition.
The document is under the responsibility of the National Medical Products Administration. This page is published from the official record of the 2013 edition. The figures, limits and tables the standard contains are those of the document itself, delivered in full with the English translation.
Found what you need?
Document preview — YY 0875-2013
National Standard of the People's Republic of China
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- 1 Scope
- 2 Normative references
- 3 Usage state
- 3.1 Cartridges
- 3.2 Reusable stapler
- 3.3 Disposable stapler
- 4 Structural types and materials
- 5 Requirements
- 6 Test methods
- 7 Marking and instructions for use
- 8 Packaging, transportation, storage and validity period
1 Foreword
YY 0875-2013 was issued by National Medical Products Administration of the People's Republic of China on 21 October 2013 and has been in force since 1 October 2014.
The YY prefix, without a suffix, marks a mandatory standard: within its scope, compliance is required.
The document runs to 16 pages in English translation.
2 Scope Preview
This standard specifies the structural types and materials, requirements, test methods, and marking, instructions for use, packaging, transportation and storage for linear staplers. This standard is applicable to linear staplers (hereinafter referred to as staplers). Staplers are suitable for sewing up the stump and incision of tissues and organs in digestive tract reconstruction and visceral organ resection operations.
YY 0875-2013 carries no ICS number and no Chinese Standard Classification code.
This catalogue holds 944 other YY standards.
Of the 199 YY standards that do carry an ICS number, 198 (99%) fall under ICS 11, in the field of health care technology.
3 Normative references
GB/T 228 — Metallic materials - Tensile testing at ambient temperature
GB/T 230.1 — Metallic materials - Rockwell hardness test - Part 1: Test method (Scales A, B, C, D, E, F, G, H, K, N, T)
GB/T 1220 — Stainless steel bars
GB/T 3280 — Cold rolled stainless steel plate, sheet and strip
GB/T 10610 — Geometrical product specifications (GPS) - Surface texture: Profile method - Rules and procedures for the assessment of surface texture
GB/T 12672 — Acrylonitrile-butadiene-styrene (ABS) resin
GB/T 13810 — Wrought titanium and titanium alloy for surgical implants
GB/T 16886.1 — Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
GB/T 16886.5 — Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicity
GB/T 16886.7 — Biological evaluation of medical devices - Part 7: Ethylene oxide sterilization residuals
GB/T 16886.10 — Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization
GB/T 19633 — Packaging for terminally sterilized medical devices
YY/T 0149-2006 — Medical instruments of stainless steel - Test methods of corrosion resistance
YY/T 0171-2008 — Surgical instruments - Packaging, marking and instructions
YY/T 0294.1 — Surgical instruments - Metallic materials - Part 1: Stainless steel
HG/T 2503 — Polycarbonate resin
ISO 13782 — :1996 Implants for surgery - Metallic materials - Unalloyed tantalum for surgical implant applications
4 About this standard
Issued by: National Medical Products Administration of the People's Republic of China
English translation: about 16 pages
5 Related standards
Other editions:
YY 0875-2023 (later edition)
Standards on related subjects:
YY/T 0908-2013 — Single-use filter for syringe
YY 0881-2013 — Single-use Huber needles used for implantable drug-supplying devices
YY 0876-2013 — Linear cutter stapler and cartridge
YY/T 0492-2026 — Implantable leads
6 Classification and status
Chinese Standard Classification (CCS): C 36
Prefix YY: mandatory standard.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
Similar standards
How to Download YY 0875-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY 0875-2013
$235.00