YY 0290.10-2009Ophthalmic optics - Intraocular lenses - Part 10: Phakic intraocular lenses (English PDF)
眼科光学 人工晶状体 第10部分:有晶体眼人工晶状体
This is a limited preview
Buy now to download the full PDF (23 pages)
Need quotation for your management?
Get a formal quotation for YY 0290.10-2009 in 30 minutes.
Issued by
NMPA
Level / Type
Industry · Mandatory
Issue date
June 16, 2009
Implementation date
December 21, 2010
Scope
YY 0290.10-2009 is the English-translated version of 眼科光学 人工晶状体 第10部分:有晶体眼人工晶状体.
YY 0290.10-2009 is the Chinese pharmaceutical industry standard for the phakic intraocular lens, the lens implanted to correct refractive error while the natural crystalline lens stays in place.
It is the tenth part of the YY 0290 series and sets the requirements and the test methods particular to such lenses, covering the dioptric power and the imaging quality, the dimensions and the vaulting over the natural lens, the materials and their biological evaluation, and the information the manufacturer must supply.
It does not cover multifocal phakic lenses nor those that correct astigmatism by another method. Issued on 16 June 2009, it has applied since 21 December 2010.
Found what you need?
Document preview — YY 0290.10-2009
National Standard of the People's Republic of China
- ICS
- 11.040.70
- Classification
- C 40
Issued by: National Medical Products Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions YY 0290.1
- 4 Optical requirements
Foreword
YY 0290 "IOL optics" is divided into nine sections.
--- Part 1. Terminology;
--- Part 2. Optical properties and test methods;
--- Part 3. Mechanical properties and test methods;
--- Part 4. Labelling and information;
--- Part 5. biocompatibility;
--- Part 6. Validity of the transport and stability;
--- Part 8. basic requirements;
--- Part 9. multifocal intraocular lens;
--- Part 10. Phakic IOL. This is Part 10 YY 0290 of.
The partial modification of the use of ISO 11979-10:2006 "Part 10 ophthalmic intraocular lens implants. phakic intraocular lens Shaped body. " This part of ISO 11979-10:2006 The main differences are as follows.
--- Its normative references have been modified;
--- Optical spectral transmission of the content requirements detailed requirements;
--- Optical imaging quality requirements in the comments directly to the requirements;
--- Mechanical requirements to determine their position size based on the contents of phakic intraocular lens design principle be refined;
--- Delete ISO standards in Appendix A and Appendix B of clinical investigation section sample size statistics.
1 Scope
This section applies to YY 0290 to correct the refractive phakic intraocular lens for the main purpose, which does not include the use of multiple Coke or other method of obtaining the same time as the optical compensation myopia phakic intraocular lens for correcting astigmatism and phakic intraocular lens Like body.
This section gives a phakic intraocular lens (PIOL) special requirements in other parts of the YY 0290 which was not given. other With the general requirements of the intraocular lens.
2 Normative references
The following documents contain provisions which, through reference in this section YY 0290 constitute provisions of this section. Cited documents dated, its All subsequent amendments (excluding corrections) or revisions do not apply to this section, however, encourage an agreement under this section Parties to study the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
YY 0290.1 IOL optics - Part 1. Terminology (YY 0290.1-2008, ISO 11979-1:2006, MOD)
YY 0290.2 IOL optics - Part 2. Optical properties and test methods (YY 0290.2-2009, ISO 11979-2:1999, MOD)
YY 0290.3 IOL optics - Part 3. Mechanical properties and test methods (YY 0290.3-2008, ISO 11979-3:2006, IDT)
YY 0290.4 optics IOL Part 4. Labelling and information (YY 0290.4-2008, ISO 11979-4. 2000, IDT)
YY 0466 medical equipment used with medical device labels, signs and symbols provide information (YY 0466-2003, ISO 15233. 2000, IDT)
3 Terms and Definitions
YY 0290.1 terms and definitions established in this section apply to YY 0290.
4 Optical requirements
4.1 General Requirements
This provision applies to the clinical application of state optical characteristics and performance requirements of the phakic IOL under.
4.2 Optical power
YY 0290.2 The requirements apply.
4.3 Image quality
YY 0290.2 The requirements apply.
NOTE: To determine the amount of negative power has the image quality of the phakic IOL, you may need to modify the measuring device (such as increasing the converging group, it may be a suitable Combined numerical aperture microscope objective, or other).
4.4 Spectral transmittance
Each type of IOL should be given at a wavelength of 300nm ~ 1100nm range for the optical power of artificial crystal -15D Like body or equivalent spectral transmittance of the recording (for example, recorded in the owner's manual or on the packaging).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 23 pages — is available in the English PDF.
Referenced standards
Normative references
- YY 0290.1Ophthalmic implants - Intraocular lenses - Part 1: Terminology
- YY 0290.2Ophthalmic optics - Intraocular lenses - Part 2: Optical properties and test methods
- YY 0290.3Ophthalmic optics—Intraocular lenses - Part 3: Mechanical properties and test methods
- YY 0290.4Ophthalmic implants - Intraocular lenses - Part 4: Labelling and information
- YY 0466Medical devices -- Symbols to be used with medical device labels labelling and information to be supplied
Similar standards
How to Download YY 0290.10-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YY 0290.1-1997 — Intraocular lenses - Part 1: Terminology
YY 0290.1-2008 — Ophthalmic implants - Intraocular lenses - Part 1: Terminology
YY 0290.2-1997 — Intraocular lenses - Part 2: Optical properties and test methods
Secure payment via Stripe
Payments accepted
YY 0290.10-2009
$75.00