Scope

YY 0018-2016 is the English-translated version of 骨接合植入物金属接骨螺钉.

YY 0018-2016 is the Chinese standard "Implants for osteosynthesis - Metallic bone screws". Its scope clause reads: This Standard specifies the terms and definitions, classification, requirements, test methods, manufacture, sterilization, packaging and information supplied by manufacturer of implants for osteosynthesis - metallic bone screws.

This Standard applies to metallic bone screws (hereinafter referred to as "bone screws"), which is used for internal fracture fixation in case of orthopedic surgery, excluding spine and specially designed bone screws. Its clauses include terms and definitions; classification.

Found what you need?

Document preview — YY 0018-2016

National Standard of the People's Republic of China

Replacing
YY 0018-2008

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Contents
  • Foreword I
  • 1 Scope
  • 2 Normative References
  • 3 Terms and Definitions
  • 4 Classification
  • 5 Requirements
  • 6 Test Method
  • 7 Manufacture
  • 8 Sterilization
  • 9 Packaging
  • 10 Information Supplied by Manufacturer
  • Appendix A (Informative) Significance of Each Parameter in Mechanical Property Requirements of this Standard
  • Appendix B (Informative) List of Approved Method Standards for Chemical Analysis
  • Appendix C (Informative) List of Approved Method Standards for Metallographic Inspection
  • Appendix D (Normative) Description for Determination Method of Maximum Torque and Breaking Angle
  • Bibliography

1 Scope

This Standard specifies the terms and definitions, classification, requirements, test methods, manufacture, sterilization, packaging and information supplied by manufacturer of implants for osteosynthesis - metallic bone screws.

This Standard applies to metallic bone screws (hereinafter referred to as "bone screws"), which is used for internal fracture fixation in case of orthopedic surgery, excluding spine and specially designed bone screws.

2 Normative References

The following documents for the application of this Document are essential. For dated reference, only the edition cited applies. For undated reference, the latest edition of the normative document (including any amendments) applies.

GB 4234 Stainless Steel for Surgical Implants

GB/T 4340.1 Metallic Materials - Vickers Hardness - Part 1: Test Method

GB/T 10610 Geometrical Product Specifications (GPS) - Surface Texture: Profile Method - Rules and Procedures for the Assessment of Surface Texture

GB/T 13810 Wrought Titanium and Titanium Alloy for Surgical Implants

GB/T 16886.5 Biological Evaluation of Medical Devices - Part 5: Test for in Vitro Cytotoxicity

GB 23102 Implants for surgery - Metallic Materials - Wrought Titanium -6Aluminium-7Niobium Alloy

YY/T 1074 Implants for Surgery - Measuring Method for Pitting Corrosion Potential on Stainless Products

YY 0341 General Technological Requirements for Non - Active Metallic Surgical Implants for Osteosynthesis

YY/T 0343 Liquid Penetrant Inspection of Metallic Surgical Implants

YY 0605.9 Implants for Surgery - Metallic Materials - Part 9: Wrought High Nitrogen Stainless Steel

YY/T 0640 Non-active Surgical Implants - General Requirements

YY/T 0662 Implants for Surgery - Metal Bone Screws with Asymmetrical Thread and Spherical Under-surface - Mechanical Requirements and Test Methods

YY/T 1504 Implants for Surgery - Metallic Bone Screws - Axial Pull-out Force Test Methods

YY/T 1505 Implants for Surgery - Metallic Bone Screws - Self-tapping Performance Test Methods

YY/T 1506 Implants for Surgery - Metallic Bone Screws - Rotary Torque Test Methods

ISO 5835 Implants for surgery - Metal Bone Screws with Hexagonal Drive Connection, Spherical Under-Surface of Head, Asymmetrical Thread - Dimensions

ISO 9268 Implants for surgery - Metal bone Screws with Conical Under-Surface of Head - Dimensions

3 Terms and Definitions

For the purpose of this document, the following terms and definitions apply.

3.1 Screw thread

Spiral groove on the surface of cylinder or cone. Protruding screw-type ridge is referred to as thread including crest and bottom.

3.2 Buttress thread

A kind of asymmetrical thread contour characterized by pressure flank approximately perpendicular to screw axis.

3.3 Screw head

Other end opposite to screw trailing end, which is used in combination with tool inserting screws.

3.4 Screw length

Entire measuring length from screw head to end.

3.5 Pitch

Distance between crests of adjacent threads.

3.6 Core diameter

Minimum diameter measured from thread root in screw threaded portion, also known as small diameter or root diameter.

3.7 Thread diameter

Maximum diameter measured from thread crest in screw threaded portion, also known as the maximum diameter.

3.8 Thread length

The length of threaded portion in screw measured from thread runout to screw end.

3.9 Thread runout

The intersection part between threaded portion and screw or screw head in screw.

3.10 Size

Marking indicating nominal thread diameter in screw.

3.11 Pilot hole

The hole drilled in the bone where screw trailing end inserts. Generally, pilot hole is slightly larger than core diameter of screw. Part of pilot hole may be larger to perform clearance fit if screw is used for broken bone pressuring.

3.12 Solid core

Screw excluding blank pipe along y-direction.

3.13 Cancellous screw

Screw that is mainly used for implanting cancellous bone, generally, it is provided with HB thread- alternative to be full or not.

3.14 Cortical screw

Screw that is mainly used for implanting cortical screw, generally, it is provided with HA thread with full thread.

3.15 Nontapping screw

Screw without slug slot on its trailing end. Where it is used for medium hard or hard skeleton, screw tap is generally required to insert the pilot hole prior to nontapping screw insertion.

3.16 Self-tapping screw

Screw with multiple slug slots on its end, which is used for tapping screw shape during insertion.

3.17 Partially threaded screw

Screw whose part from end to head not completely covered by thread while smooth bar is existing between both.

3.18 Gage length

Distance from fixture (e.g. chuck) to bottom of screw head.

3.19 Grip length

Length of thread fastened in fixture or other equipment.

3.20 Maximum torque

Maximum torque value of screw recorded before its torsion shear breaking, in N·m.

3.21 Breaking angle

Rotary angle of screw during its torsion faults, displayed as rapid decrease of indicated torque.

3.22 Axial pullout strength

Drawing force required to pull out the bone screw from inserted material or pull it out until damage, in N.

3.23 Insertion depth

Depth of thread section inserted in the testing material.

3.24 Insertion torque

Torque required for overcoming the friction force between screw and testing material when screw is inserted in testing material.

3.25 Removal torque

Torque required for overcoming the friction force between screw and testing material when screw is removed from testing material (e.g. counter clockwise rotation is adopted for right hand thread).

3.26 Self-tapping force

The value of axial force required by self-tapping screw to perform self-tapping, in N.

3.27 Torsional yield strength

Proportional limit that the screw can reach, in N. Translation method is adopted for determination with translation amount of 2°.

4 Classification

4.1 Types of bone screws

Bone screws include many different categories with types as shown in Table 1 and specific description methods as follows:

- HA, with spherical undersurface of screw head and shallow saw-tooth asymmetrical thread;

- HB, with spherical undersurface of screw head and deep saw-tooth asymmetrical thread;

- HC, with conical undersurface of screw head and symmetrical thread;

- HD, with conical undersurface of screw head and asymmetrical thread;

Note: Special construction or specification is specified by manufacturer in accordance with clinical demand.

Table 1 Type of Bone Screws

Thread types Bone screws

HA HB HC HD Undersurface of screw head

Spherical

Conical

Drive connection

Hexagonal

Slot Cross recess Cross-recessed head

Compound drive connection

4.2 HA bone screw

HA bone screw is as shown in Figure 1 with sizes in Table 2.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of YY 0018

EditionTitleRevisionStatus
YY 0018-2016Implants for osteosynthesis - Metallic bone screwscurrent editionCurrent
YY 0018-2008Implants for osteosynthesis - Metallic bone screwsprevious editionSuperseded

This page sells the current edition, YY 0018-2016. Earlier editions are listed for reference only.

How to Download YY 0018-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY 0018-2016

$135.00