Valid

YS/T 928.4-2013Methods for chemical analysis of nickel cobalt manganese composite hydrogen oxide - Part 4: Determination of iron, calcium, magnesium, copper, zinc, silicon, aluminium, sodium contents - Inductively coupled plasma atomic emission spectrometric (English PDF)

镍、钴、锰三元素氢氧化物化学分析方法 第4部分:铁、钙、镁、铜、锌、硅、铝、钠量的测定 电感耦合等离子体原子发射光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (10 pages)

Need quotation for your management?

Get a formal quotation for YS/T 928.4-2013 in 30 minutes.

Issued by

Ministry of Industry and Information Technology of the People’s Republic of China

Level / Type

National · Recommended

Issue date

October 17, 2013

Implementation date

March 1, 2014

Scope

YS/T 928.4-2013 is the English-translated version of 镍、钴、锰三元素氢氧化物化学分析方法 第4部分:铁、钙、镁、铜、锌、硅、铝、钠量的测定 电感耦合等离子体原子发射光谱法.

YS/T 928.4-2013 - This Part of YS/T 928 specifies the method for the determination of iron, calcium, magnesium, copper, zinc, silicon, aluminum and sodium content in nickel cobalt manganese composite hydrogenoxide.

This Part is applicable to the determination of iron, calcium, magnesium, copper, zinc, silicon, aluminum and sodium content in nickel cobalt manganese composite hydrogenoxide. See Table

Found what you need?

Document preview — YS/T 928.4-2013

National Standard of the People's Republic of China

ICS
77.120.60
Classification
H 13

Issued by: Ministry of Industry and Information Technology of the People’s Republic of China

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Method Summary...4
  • 3 Reagents...5
  • 4 Instrument...6
  • 5 Analytical Procedures...7
  • 6 Calculation and Expression of Analysis Results...8
  • 7 Precision...8
  • 8 Test Report...10

Foreword

YS/T 928 Methods for Chemical Analysis of Nickel Cobalt Manganese Composite

Hydrogenoxide includes the following six parts.

---Part 1.Determination of Chloride Ion Contents - Silver Chloride Turbidimetry;

---Part 2.Determination of Nickel Contents - Dimethylglyoxime Gravimetric;

---Part 3.Determination of Nickel, Cobalt, Manganese Content - Inductively Coupled

Plasma Atomic Emission Spectrometric;

---Part 4.Determination of Iron, Calcium, Magnesium, Copper, Zinc, Silicon, Aluminum,

Sodium Contents - Inductively Coupled Plasma Atomic Emission Spectrometric;

---Part 5.Determination of Lead Contents - Inductively Coupled Plasma Mass

Spectrometry;

---Part 6.Determination of Sulfate Ion Contents - Ion Chromatography.

This is Part 4 of YS/T 928.

This Part was drafted in accordance with the rules provided in GB/T 1.1-2009.

This Standard shall be under the jurisdiction of National Technical Committee 243 on

Nonferrous Metals of Standardization Administration of China (SAC/TC 243).

The responsible drafting organizations of this Standard. Jinchuan Group Co., Ltd.; Foshan

BRUNP Recycling Technology Co., Ltd.; Beijing BGRIMM Research Institute of Mining &

Metallurgy.

The drafting organizations of this Part. Jinchuan Group Co., Ltd.; Foshan BRUNP Recycling

Technology Co., Ltd.

The participating drafting organizations of this Part. Zhejiang Huayou Cobalt Co., Ltd.; Tianjin

Maolian Technology Co., Ltd.; CITIC Guoan MGL Power Technology Co., Ltd.

1 Scope

This Part of YS/T 928 specifies the method for the determination of iron, calcium, magnesium,

copper, zinc, silicon, aluminum and sodium content in nickel cobalt manganese composite

hydrogenoxide.

This Part is applicable to the determination of iron, calcium, magnesium, copper, zinc, silicon,

aluminum and sodium content in nickel cobalt manganese composite hydrogenoxide. See Table

1 for the determination scope.

Table 1 -- Determination Scope

2 Method Summary

Use hydrochloric acid to dissolve the test portion and adopt an inductively coupled plasma

atomic emission spectrometer to directly conduct the determination. In accordance with the

working curve method, calculate the concentration of each element. Express the determination

results in mass fraction.

Element Determination Scope (w)/%

3 Reagents

All reagents used in this Part are of top-grade purity, and only pure water with an electrical

resistivity of not less than 18.2 Mohm - cm shall be used in the analysis.

3.1 Hydrochloric acid (rho = 1.19 g/mL).

3.2 Nitric acid (rho = 1.42 g/mL).

3.3 Hydrochloric acid (1 + 1).

3.4 Nitric acid (1 + 1).

3.8 Copper standard stock solution. weigh-take 0.2000 g of pure copper (wCu >= 99.99%) in a

300 mL beaker, slowly add 30 mL of nitric acid (3.4), use a watch glass to cover it; at a low

temperature, dissolve it and drive out nitrogen oxides, then, remove and cool it. Use water to

wash the watch glass and beaker wall. Transfer to a 1,000 mL volumetric flask, use water to

dilute to the scale and mix it well. 1 mL of this solution contains 200 µg of copper.

3.13 Aluminum, magnesium, calcium, copper, iron and zinc standard solutions. accurately

transfer-take 10.00 mL of the standard stock solutions (3.5, 3.6, 3.7, 3.8, 3.9 and 3.10) in a 200

mL volumetric flask. Use water to dilute to the scale and mix it well. 1 mL of this solution

contains 10 µg of aluminum, magnesium, calcium, copper, iron and zinc.

3.14 Sodium standard solution. accurately transfer-take 10.00 mL of the standard stock solution

(3.11) in a 200 mL volumetric flask. Use water to dilute to the scale, mix it well, and

immediately transfer it into a dry plastic bottle. 1 mL of this solution contains 10 µg of sodium.

3.15 Silicon standard solution. accurately transfer-take 10.00 mL of the standard stock solution

(3.12) in a 200 mL volumetric flask. Use water to dilute to the scale, mix it well, and

immediately transfer it into a dry plastic bottle. 1 mL of this solution contains 10 µg of silicon.

4 Instrument

In terms of the inductively coupled plasma atomic emission spectrometer, the spectral lines of

the various element are shown in Table 2; the working parameters of the instrument for sodium

determination are shown in Table 3; the working parameters of the instrument for the

determination of other elements are shown in Table 4.

5 Analytical Procedures

5.1 Test Portion

Weigh-take two portions of 0.20 g of specimen, accurate to 0.0001 g.

5.2 Blank Test

Along with the specimen, conduct the blank test.

5.3 Treatment of Test Portion

Place the test portion (5.1) in a 100 mL polytetrafluoroethylene beaker, add 20 mL of

hydrochloric acid (3.3), use a watch glass to cover it, dissolve it with slight heat. After the test

portion is completely dissolved, remove it, cool it, then, use water to wash the watch glass and

beaker wall. Transfer it to a 200 mL volumetric flask, use water to dilute to the scale and mix it

well. On an inductively coupled plasma atomic emission spectrometer, conduct the

determination.

5.4 Drawing of Working Curve

7 Precision

7.1 Repeatability

Under repeatability conditions, obtain the determined values of two independent test results.

Within the average value range provided in Table 5, the absolute difference between the two

test results does not exceed the repeatability limit (r), and the circumstances of exceeding the

repeatability limit (r) does not exceed 5%. The repeatability limit (r) is calculated using the

linear interpolation method and the extrapolation method in accordance with the data in Table

5.

8 Test Report

The test report shall include the following content.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.

Referenced standards

How to Download YS/T 928.4-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
10 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 928.4-2013