YS/T 928.4-2013Methods for chemical analysis of nickel cobalt manganese composite hydrogen oxide - Part 4: Determination of iron, calcium, magnesium, copper, zinc, silicon, aluminium, sodium contents - Inductively coupled plasma atomic emission spectrometric (English PDF)
镍、钴、锰三元素氢氧化物化学分析方法 第4部分:铁、钙、镁、铜、锌、硅、铝、钠量的测定 电感耦合等离子体原子发射光谱法
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for YS/T 928.4-2013 in 30 minutes.
Issued by
Ministry of Industry and Information Technology of the People’s Republic of China
Level / Type
National · Recommended
Issue date
October 17, 2013
Implementation date
March 1, 2014
Scope
YS/T 928.4-2013 is the English-translated version of 镍、钴、锰三元素氢氧化物化学分析方法 第4部分:铁、钙、镁、铜、锌、硅、铝、钠量的测定 电感耦合等离子体原子发射光谱法.
YS/T 928.4-2013 - This Part of YS/T 928 specifies the method for the determination of iron, calcium, magnesium, copper, zinc, silicon, aluminum and sodium content in nickel cobalt manganese composite hydrogenoxide.
This Part is applicable to the determination of iron, calcium, magnesium, copper, zinc, silicon, aluminum and sodium content in nickel cobalt manganese composite hydrogenoxide. See Table
Found what you need?
Document preview — YS/T 928.4-2013
National Standard of the People's Republic of China
- ICS
- 77.120.60
- Classification
- H 13
Issued by: Ministry of Industry and Information Technology of the People’s Republic of China
Contents
- Foreword...3
- 1 Scope...4
- 2 Method Summary...4
- 3 Reagents...5
- 4 Instrument...6
- 5 Analytical Procedures...7
- 6 Calculation and Expression of Analysis Results...8
- 7 Precision...8
- 8 Test Report...10
Foreword
YS/T 928 Methods for Chemical Analysis of Nickel Cobalt Manganese Composite
Hydrogenoxide includes the following six parts.
---Part 1.Determination of Chloride Ion Contents - Silver Chloride Turbidimetry;
---Part 2.Determination of Nickel Contents - Dimethylglyoxime Gravimetric;
---Part 3.Determination of Nickel, Cobalt, Manganese Content - Inductively Coupled
Plasma Atomic Emission Spectrometric;
---Part 4.Determination of Iron, Calcium, Magnesium, Copper, Zinc, Silicon, Aluminum,
Sodium Contents - Inductively Coupled Plasma Atomic Emission Spectrometric;
---Part 5.Determination of Lead Contents - Inductively Coupled Plasma Mass
Spectrometry;
---Part 6.Determination of Sulfate Ion Contents - Ion Chromatography.
This is Part 4 of YS/T 928.
This Part was drafted in accordance with the rules provided in GB/T 1.1-2009.
This Standard shall be under the jurisdiction of National Technical Committee 243 on
Nonferrous Metals of Standardization Administration of China (SAC/TC 243).
The responsible drafting organizations of this Standard. Jinchuan Group Co., Ltd.; Foshan
BRUNP Recycling Technology Co., Ltd.; Beijing BGRIMM Research Institute of Mining &
Metallurgy.
The drafting organizations of this Part. Jinchuan Group Co., Ltd.; Foshan BRUNP Recycling
Technology Co., Ltd.
The participating drafting organizations of this Part. Zhejiang Huayou Cobalt Co., Ltd.; Tianjin
Maolian Technology Co., Ltd.; CITIC Guoan MGL Power Technology Co., Ltd.
1 Scope
This Part of YS/T 928 specifies the method for the determination of iron, calcium, magnesium,
copper, zinc, silicon, aluminum and sodium content in nickel cobalt manganese composite
hydrogenoxide.
This Part is applicable to the determination of iron, calcium, magnesium, copper, zinc, silicon,
aluminum and sodium content in nickel cobalt manganese composite hydrogenoxide. See Table
1 for the determination scope.
Table 1 -- Determination Scope
2 Method Summary
Use hydrochloric acid to dissolve the test portion and adopt an inductively coupled plasma
atomic emission spectrometer to directly conduct the determination. In accordance with the
working curve method, calculate the concentration of each element. Express the determination
results in mass fraction.
Element Determination Scope (w)/%
3 Reagents
All reagents used in this Part are of top-grade purity, and only pure water with an electrical
resistivity of not less than 18.2 Mohm - cm shall be used in the analysis.
3.1 Hydrochloric acid (rho = 1.19 g/mL).
3.2 Nitric acid (rho = 1.42 g/mL).
3.3 Hydrochloric acid (1 + 1).
3.4 Nitric acid (1 + 1).
3.8 Copper standard stock solution. weigh-take 0.2000 g of pure copper (wCu >= 99.99%) in a
300 mL beaker, slowly add 30 mL of nitric acid (3.4), use a watch glass to cover it; at a low
temperature, dissolve it and drive out nitrogen oxides, then, remove and cool it. Use water to
wash the watch glass and beaker wall. Transfer to a 1,000 mL volumetric flask, use water to
dilute to the scale and mix it well. 1 mL of this solution contains 200 µg of copper.
3.13 Aluminum, magnesium, calcium, copper, iron and zinc standard solutions. accurately
transfer-take 10.00 mL of the standard stock solutions (3.5, 3.6, 3.7, 3.8, 3.9 and 3.10) in a 200
mL volumetric flask. Use water to dilute to the scale and mix it well. 1 mL of this solution
contains 10 µg of aluminum, magnesium, calcium, copper, iron and zinc.
3.14 Sodium standard solution. accurately transfer-take 10.00 mL of the standard stock solution
(3.11) in a 200 mL volumetric flask. Use water to dilute to the scale, mix it well, and
immediately transfer it into a dry plastic bottle. 1 mL of this solution contains 10 µg of sodium.
3.15 Silicon standard solution. accurately transfer-take 10.00 mL of the standard stock solution
(3.12) in a 200 mL volumetric flask. Use water to dilute to the scale, mix it well, and
immediately transfer it into a dry plastic bottle. 1 mL of this solution contains 10 µg of silicon.
4 Instrument
In terms of the inductively coupled plasma atomic emission spectrometer, the spectral lines of
the various element are shown in Table 2; the working parameters of the instrument for sodium
determination are shown in Table 3; the working parameters of the instrument for the
determination of other elements are shown in Table 4.
5 Analytical Procedures
5.1 Test Portion
Weigh-take two portions of 0.20 g of specimen, accurate to 0.0001 g.
5.2 Blank Test
Along with the specimen, conduct the blank test.
5.3 Treatment of Test Portion
Place the test portion (5.1) in a 100 mL polytetrafluoroethylene beaker, add 20 mL of
hydrochloric acid (3.3), use a watch glass to cover it, dissolve it with slight heat. After the test
portion is completely dissolved, remove it, cool it, then, use water to wash the watch glass and
beaker wall. Transfer it to a 200 mL volumetric flask, use water to dilute to the scale and mix it
well. On an inductively coupled plasma atomic emission spectrometer, conduct the
determination.
5.4 Drawing of Working Curve
7 Precision
7.1 Repeatability
Under repeatability conditions, obtain the determined values of two independent test results.
Within the average value range provided in Table 5, the absolute difference between the two
test results does not exceed the repeatability limit (r), and the circumstances of exceeding the
repeatability limit (r) does not exceed 5%. The repeatability limit (r) is calculated using the
linear interpolation method and the extrapolation method in accordance with the data in Table
5.
8 Test Report
The test report shall include the following content.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
Referenced standards
How to Download YS/T 928.4-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 928.1-2013 — Methods for chemical analysis of nickel cobalt manganese composite hydrogenoxide. Part 1: Determination of chloride ion contents. Silver chloride turbidimetry
YS/T 928.2-2013 — Methods for chemical analysis of nickel cobalt manganese composite hydrogenoxide. Part 2: Determination of nickel cntents. Dimethylglyoxime gravimetric
YS/T 928.3-2013 — Methods for chemical analysis of nickel cobalt manganese composite hydrogenoxide. Part 3: Determination of nickel, cobalt, manganese content. Inductively coupled plasma atomic emission spectromertric
Secure payment via Stripe
Payments accepted
YS/T 928.4-2013
$145.00