YS/T 928.3-2013Methods for chemical analysis of nickel cobalt manganese composite hydrogenoxide. Part 3: Determination of nickel, cobalt, manganese content. Inductively coupled plasma atomic emission spectromertric (English PDF)
镍、钴、锰三元素氢氧化物化学分析方法 第3部分:镍、钴、锰量的测定电感耦合等离子体原子发射光谱法
This is a limited preview
Buy now to download the full PDF (8 pages)
Need quotation for your management?
Get a formal quotation for YS/T 928.3-2013 in 30 minutes.
Issued by
Ministry of Industry and Information Technology of the People’s Republic of China
Level / Type
National · Recommended
Issue date
October 17, 2013
Implementation date
March 1, 2014
Scope
YS/T 928.3-2013 is the English-translated version of 镍、钴、锰三元素氢氧化物化学分析方法 第3部分:镍、钴、锰量的测定电感耦合等离子体原子发射光谱法.
YS/T 928.3-2013 - This Part of YS/T 928 specifies the method for the determination of nickel, cobalt and manganese content in nickel cobalt manganese composite hydrogenoxide.
This Part is applicable to the determination of nickel, cobalt and manganese content in nickel cobalt manganese composite hydrogenoxide. See Table 1 for the determination scope. Table 1 -- Determination Scope
Found what you need?
Document preview — YS/T 928.3-2013
National Standard of the People's Republic of China
- ICS
- 77.120.60
- Classification
- H 13
Issued by: Ministry of Industry and Information Technology of the People’s Republic of China
Contents
- Foreword...3
- 1 Scope...4
- 2 Method Summary...4
- 3 Reagents...4
- 4 Instrument...6
- 5 Analytical Procedures...6
- 6 Calculation and Expression of Analysis Results...7
- 7 Precision...8
- 8 Test Report...8
Foreword
YS/T 928 Methods for Chemical Analysis of Nickel Cobalt Manganese Composite
Hydrogenoxide includes the following six parts.
---Part 1.Determination of Chloride Ion Contents - Silver Chloride Turbidimetry;
---Part 2.Determination of Nickel Contents - Dimethylglyoxime Gravimetric;
---Part 3.Determination of Nickel, Cobalt, Manganese Content - Inductively Coupled
Plasma Atomic Emission Spectrometric;
---Part 4.Determination of Iron, Calcium, Magnesium, Copper, Zinc, Silicon, Aluminum,
Sodium Contents - Inductively Coupled Plasma Atomic Emission Spectrometric;
---Part 5.Determination of Lead Contents - Inductively Coupled Plasma Mass
Spectrometry;
---Part 6.Determination of Sulfate Ion Contents - Ion Chromatography.
This is Part 3 of YS/T 928.
This Part was drafted in accordance with the rules provided in GB/T 1.1-2009.
This Standard shall be under the jurisdiction of National Technical Committee 243 on
Nonferrous Metals of Standardization Administration of China (SAC/TC 243).
The responsible drafting organizations of this Standard. Jinchuan Group Co., Ltd.; Foshan
BRUNP Recycling Technology Co., Ltd.; Beijing BGRIMM Research Institute of Mining &
Metallurgy.
The drafting organizations of this Part. Jinchuan Group Co., Ltd.; Foshan BRUNP Recycling
Technology Co., Ltd.
The participating drafting organizations of this Part. Hunan Nonferrous Metals Research
Institute; Yingde Jiana Metal Technology Co., Ltd.; CITIC Guoan MGL Power Technology Co.,
Ltd.; Tianjin Maolian Technology Co., Ltd.
1 Scope
This Part of YS/T 928 specifies the method for the determination of nickel, cobalt and
manganese content in nickel cobalt manganese composite hydrogenoxide.
This Part is applicable to the determination of nickel, cobalt and manganese content in nickel
cobalt manganese composite hydrogenoxide. See Table 1 for the determination scope.
Table 1 -- Determination Scope
2 Method Summary
Use hydrochloric acid to dissolve the test portion, use yttrium as the internal standard, and adopt
an inductively coupled plasma atomic emission spectrometer to determine the elements to be
analyzed.
3 Reagents
Unless it is otherwise stated, only reagents confirmed to be analytically pure and pure water
with an electrical resistivity of not less than 18.2 Mohm - cm shall be used in the analysis.
3.1 Hydrochloric acid (rho = 1.19 g/mL).
3.2 Nitric acid (rho = 1.42 g/mL).
3.3 Hydrochloric acid (1 + 1).
3.4 Nitric acid (1 + 1).
Element Determination Scope/%
3.7 Nickel standard stock solution. weigh-take 2.0000 g of pure nickel (wNi >= 99.99%) in a 300
mL beaker, add 40 mL of hydrochloric acid (3.1) and 5 mL of nitric acid (3.2); heat to dissolve
it. Boil to remove nitrogen oxides, remove and cool it, then, use water to wash the watch glass
and beaker wall. Transfer to a 500 mL volumetric flask, use water to dilute to the scale and mix
it well. 1 mL of this solution contains 4 mg of nickel.
3.10 Nickel cobalt manganese standard solution 955.accurately transfer-take 15.00 mL, 20.00
mL and 30.00 mL of nickel standard stock solution (3.7), and 2.00 mL, 3.00 mL and 5.00 mL
of cobalt standard stock solution (3.8) and manganese standard stock solution (3.9) in a group
of 200 mL volumetric flasks. Respectively add 2.00 mL of yttrium internal standard solution A
(3.5), use water to dilute to the scale and mix it well.
3.11 Nickel cobalt manganese standard solution 811.accurately transfer-take 15.00 mL, 20.00
mL and 25.00 mL of nickel standard stock solution (3.7), and 5.00 mL, 7.00 mL and 10.00 mL
of cobalt standard stock solution (3.8) and manganese standard stock solution (3.9) in a group
of 200 mL volumetric flasks. Respectively add 2.00 mL of yttrium internal standard solution A
(3.5), use water to dilute to the scale and mix it well.
3.12 Nickel cobalt manganese standard solution 523.accurately transfer-take 10.00 mL, 15.00
mL and 18.00 mL of nickel standard stock solution (3.7), and 10.00 mL, 12.00 mL and 15.00
mL of cobalt standard stock solution (3.8), and 10.00 mL, 15.00 mL and 20.00 mL of manganese
standard stock solution (3.9) in a group of 200 mL volumetric flasks. Respectively add 2.00 mL
of yttrium internal standard solution A (3.5), use water to dilute to the scale and mix it well.
3.13 Nickel cobalt manganese standard solution 424.accurately transfer-take 10.00 mL, 12.00
mL and 15.00 mL of nickel standard stock solution (3.7) and cobalt standard stock solution
(3.8), and 15.00 mL, 25.00 mL and 30.00 mL of manganese standard stock solution (3.9) in a
group of 200 mL volumetric flasks. Respectively add 2.00 mL of yttrium internal standard
solution A (3.5), use water to dilute to the scale and mix it well.
4 Instrument
The working parameters of the inductively coupled plasma atomic emission spectrometer are
shown in Table 2.
5 Analytical Procedures
5.1 Test Portion
Weigh-take two portions of 0.20 g of specimen, accurate to 0.0001 g.
5.2 Blank Test
Along with the specimen, conduct the blank test.
5.3 Treatment of Test Portion
Place the test portion (5.1) in a 300 mL beaker, add 20 mL of hydrochloric acid (3.3), use a
watch glass to cover it; completely dissolve it at low temperature. Remove and cool it, then,
use water to wash the watch glass and beaker wall.
5.4 Drawing of Working Curve
On the ICP optical spectrometer, in accordance with the condition parameters provided in Table
2 and Table 3, use yttrium internal standard solution B (3.6) and nickel cobalt manganese
standard solutions (3.10, 3.11, 3.12, 3.13, 3.14 and 3.15) to measure the intensity values of the
nickel, cobalt and manganese standard solutions.
6 Calculation and Expression of Analysis Results
In accordance with Formula (1), calculate the mass fraction wx of the element being determined
and express it as a percentage.
7 Precision
7.1 Repeatability
Under repeatability conditions, obtain the determined values of two independent test results.
Within the average value range provided in Table 5, the absolute difference between the two
test results does not exceed the repeatability limit (r), and the circumstances of exceeding the
repeatability limit (r) does not exceed 5%. The repeatability limit (r) is calculated using the
linear interpolation method and the extrapolation method in accordance with the data in Table
4.
8 Test Report
The test report shall include the following content.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.
Referenced standards
How to Download YS/T 928.3-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 928.1-2013 — Methods for chemical analysis of nickel cobalt manganese composite hydrogenoxide. Part 1: Determination of chloride ion contents. Silver chloride turbidimetry
YS/T 928.2-2013 — Methods for chemical analysis of nickel cobalt manganese composite hydrogenoxide. Part 2: Determination of nickel cntents. Dimethylglyoxime gravimetric
YS/T 928.3-2026 — Chemical analysis methods of nickel cobalt manganese ternary precursor - Part 3: Determination of nickel, cobalt and manganese contents - Na2EDTA titration method and inductively coupled plasma atomic emission spectrometry
Secure payment via Stripe
Payments accepted
YS/T 928.3-2013
$85.00