YS/T 745.7-2010Methods for chemical analysis of copper anode slime. Part 7: Determination of bismuth content. Flame atomic absorption spectrometric method and Na2EDTA titrimetric method (English PDF)
铜阳极泥化学分析方法 第7部分:铋量的测定 火焰原子吸收光谱法和Na2EDTA滴定法
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for YS/T 745.7-2010 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
November 22, 2010
Implementation date
March 1, 2011
Scope
YS/T 745.7-2010 is the English-translated version of 铜阳极泥化学分析方法 第7部分:铋量的测定 火焰原子吸收光谱法和Na2EDTA滴定法.
YS/T 745.7-2010 — 1 Scope YS/T 745 method specifies the method for determination of bismuth in copper anode mud content. This method is applicable to the determination of bismuth in copper anode mud, the measurement range. 1.00% to 5.00%.
Found what you need?
Document preview — YS/T 745.7-2010
National Standard of the People's Republic of China
- ICS
- 77.120.01
- Classification
- H 14
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Method, flame atomic absorption spectrometry
- 2 Method summary
- 3 Reagents
- 4 Instrument
Foreword
YS/T 745 "Methods for chemical analysis of copper anode mud" is divided into nine sections.
--- Part 1. Determination of copper content iodometry;
--- Part 2. gold and silver content determination fire assay gravimetric method;
--- Part 3. the amount of platinum and palladium contents - fire assay enrichment - Inductively coupled plasma atomic emission spectrometry;
--- Part 4. Determination of the amount of selenium iodometry;
--- Part 5. Determination of tellurium content dichromate method;
--- Part 6. Determination of lead content Na2EDTA titration;
--- Part 7. Determination of bismuth content - Flame atomic absorption spectrometric method and Na2EDTA titration;
--- Part 8. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry;
--- Part 9. Determination of antimony content - Flame atomic absorption spectrometry.
This is Part 7.
This section is in accordance with GB/T 1.1-2009 given rules drafted.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized.
This section is responsible for drafting unit. Daye Nonferrous Metals Corporation.
This section is drafted. Daye Nonferrous Metals Corporation.
Participated in the drafting of this section. Beijing Institute of Mining and Metallurgy, Jinchuan Group Limited, Northern Copper Co., Ltd., Yunnan Copper shares Parts Co., Dongling Smelting limited liability company.
The method of one of the main drafters of. Costume Hujun Kai, Ho Mei, Zhang Wei, Yindong Xia, Yuan Yuxia, Pan Lijuan, Liu Xiaoli, often wing Xiang, Ma Lijun, Zheng Wenying, Chen Yu Bin, car Hongfang.
Method Two main drafters. Ho Mei, Hujun Kai, Yuan Yuxia, Wang Lin, Chang wing Xiang, Ma Lijun, Zheng Wenying, Yu Chen Bin, car Hongfang.
Methods for chemical analysis of copper anode slime Part 7. Determination of bismuth content Flame atomic absorption spectrometry and titration Na2EDTA
1 Method, flame atomic absorption spectrometry
1 Scope
YS/T 745 method specifies the method for determination of bismuth in copper anode mud content.
This method is applicable to the determination of bismuth in copper anode mud, the measurement range. 1.00% to 5.00%.
2 Method summary
Sample with a mixed acid dissolved, antimony tartrate eliminate interference, the use of air - acetylene flame atomic absorption spectrometer wavelength 223.1nm Bismuth measured absorbance, calculated according to the quality of working curves bismuth score.
3 Reagents
Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity.
3.1 hydrochloride (rho1.19g/mL).
3.2 hydrochloric acid (119).
Nitrate 3.3 (rho1.42g/mL).
3.4 mixed acid. hydrochloric acid, nitric acid (31).
3.5 tartaric acid solution (200g/L).
3.6 Bismuth standard solution. Weigh 0.5000g of bismuth (>=99.99%), placed in 250mL beaker, add 50mL of nitric acid (11), cover Dish surface, low heat until completely dissolved, boiled to remove nitrogen oxides, removed, cooled, treated with nitric acid (124) and the cup wall detersive dish, transferred 1000mL volumetric flask, and dilute to volume with nitric acid (124), and mix. This solution 1mL containing 0.5mg bismuth.
4 Instrument
Atomic absorption spectrometer, with a bismuth hollow cathode lamp.
Under optimum working conditions for those who can reach the following indicators can be used.
--- Sensitivity. a solution consistent with the measurement matrix solution, measuring the characteristic concentration of bismuth standard solution should be less than 0.35µg/mL.
--- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed the average absorbance of 1.0% the lowest concentration of standard solution used (instead of "zero" concentration of the solution) absorbance measured 10 times, and the standard deviation is not more than the highest standard concentration 0.5% average standard solution absorbance.
--- Working curve. The curve will be divided into five sections according to concentration, than the difference between the absorbance of the absorbance values of the highest and the lowest segment should not less than 0.75.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
How to Download YS/T 745.7-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 745.1-2010 — Methods for chemical analysis of copper anode slime. Part 1: Determination of copper content. Iodine titration method
YS/T 745.10-2023 — Methods for chemical analysis of copper anode slime - Part 10: Determination of iridium and rhodium content - nickel matte assay - inductively coupled plasma mass spectrometry
YS/T 745.11-2023 — Methods for chemical analysis of copper anode slime - Part 11: Determination of indium content - Flame atomic absorption spectrometry
Secure payment via Stripe
Payments accepted
YS/T 745.7-2010
$165.00