Valid

YS/T 600-2009Analysis method of hydrogen in liquid aluminum and aluminum alloys the method of the closed gas loop circulation (English PDF)

Preview PDF

Also coversYST600-2009

This is a limited preview

Buy now to download the full PDF (8 pages)

Need quotation for your management?

Get a formal quotation for YS/T 600-2009 in 30 minutes.

Issued by

Ministry of Industry and Information Technology of the PRC

Level / Type

National · Recommended

Issue date

December 4, 2009

Implementation date

June 1, 2010

Scope

YS/T 600-2009 (Analysis method of hydrogen in liquid aluminum and aluminum alloys the method of the closed gas loop circulation) is available as an English-translated PDF.

YS/T 600-2009 is the Chinese standard "Analysis method of hydrogen in liquid aluminum and aluminum alloys the method of the closed gas loop circulation".

Its scope clause reads: This Standard specifies the measurement principle, instrument requirements, test conditions, test procedures, and test report of the closed gas loop circulation method for measuring hydrogen content in liquid aluminum and aluminum alloys.

This Standard applies to the determination of hydrogen content in liquid aluminum and aluminum alloys. Its clauses include measurement principle; test conditions; test procedures.

It was issued by the Ministry of Industry and Information Technology of the PRC on 2009-12-04 and took effect on 2010-06-01.

Found what you need?

Document preview — YS/T 600-2009

National Standard of the People's Republic of China

ICS
77.040.99
Classification
H 12

Issued by: Ministry of Industry and Information Technology of the PRC

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Measurement principle...4
  • 3 Instrument requirements...6
  • 4 Test conditions...7
  • 5 Test procedures...7
  • 6 Test report...8

1 Scope

This Standard specifies the measurement principle, instrument requirements, test conditions, test procedures, and test report of the closed gas loop circulation method for measuring hydrogen content in liquid aluminum and aluminum alloys.

This Standard applies to the determination of hydrogen content in liquid aluminum and aluminum alloys.

2 Measurement principle

The closed gas loop circulation method uses a circulation system to promote the diffusion of hydrogen in the aluminum melt into a quantitative volume of inert gas, until the hydrogen partial pressure reaches equilibrium. It uses the thermal conductivity test principle to test the change in thermal conductivity of circulating gas due to hydrogen, and measure the partial pressure of hydrogen Pi. The calculation method of hydrogen content is as shown in formula (1):

where:

[H] - the hydrogen content, in cubic centimeter per 100 grams of aluminum (cm3/100 g Al);

Pi - the hydrogen partial pressure, in kilopascal (kPa);

K - the alloy correction coefficient, determined by referring to formula (2). The correction coefficient K of commonly used aluminum and aluminum alloys is shown in Table 1;

S0 - the solubility of hydrogen in pure aluminum, which is a function of temperature, as shown in formula (3), in cubic centimeter per 100 grams of aluminum (cm3/100 g Al).

3.5 Repeatability: relative standard deviation <= 2.5 %.

3.6 Calibration error: <= 5 %.

3.7 Directly display hydrogen content.

4 Test conditions

4.1 Environmental requirements: temperature 0 °C ~ 50 °C, no electromagnetic

interference that affects the normal operation of the instrument, and no corrosive gases.

4.2 Carrier gas source: selected according to the requirements of the instrument.

4.3 Hydrogen measuring probe: selected according to the requirements of the

instrument, and it will not pollute the aluminum melt being measured under the test conditions.

4.4 Temperature measurement probe: selected according to the requirements of the

instrument, and it will not pollute the aluminum melt being measured under the test conditions.

5 Test procedures

5.1 Instrument calibration

5.1.1 The instrument shall be carefully inspected and tested before use.

5.1.2 The instrument shall be tested with hydrogen in nitrogen standard gas and meet the requirement of calibration error.

5.2 Instrument preheating

Before using the instrument, it shall be powered on and preheated for 10 minutes.

5.3 Probe preheating

The hydrogen measuring probe shall be fully preheated according to the requirements of the selected instrument before use.

5.4 Data measurement

When measuring hydrogen, the measurement shall be repeated multiple times. When the difference between two consecutive data does not exceed the requirements in Table

2, the measurement is completed. The temperature shall be measured simultaneously with each measurement.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

Referenced standards

How to Download YS/T 600-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 600-2009

$105.00