Scope

YS/T 575.24-2009 is the English-translated version of 铝土矿石化学分析方法 第24部分:碳和硫含量的测定 红外吸收法.

YS/T 575.24-2009 — This Part specifies the determination of carbon and sulfur content in aluminum ores. This Part is applicable to the determination of carbon and sulfur content in aluminum ores.

The range of determination (mass fraction) is: for carbon, 0.02% ~ 10.00%; for sulfur, 0.020% ~ 12.00%.

Found what you need?

Document preview — YS/T 575.24-2009

National Standard of the People's Republic of China

ICS
77.120.10
Classification
H 30

Issued by: Ministry of Industry and Information Technology of the People’s Republic of China

Contents

  • Foreword...3
  • 1 Scope...5
  • 2 Method Summary...5
  • 3 Reagents and Materials...5
  • 4 Instruments and Equipment...6
  • 5 Sample...6
  • 6 Analytical Procedures...6
  • 7 Analysis Result...8
  • 8 Precision...8
  • 9 Quality Assurance and Control...9

Foreword

YS/T 575 Method for Chemical Analysis of Aluminum Ores is divided into 24 parts:

---Part 1: Determination of Aluminum Oxide Content - EDTA Titrimetric Method;

---Part 2: Determination of Silicon Dioxide Content - Gravimetric-molybdenum

Blue Photometric Method;

---Part 3: Determination of Silicon Dioxide Content - Molybdenum Blue

Photometric Method;

---Part 4: Determination of Iron Oxide Content - Dichromate Titrimetric Method;

---Part 5: Determination of Iron Oxide Content - Orthophenanthroline Photometric

Method;

---Part 6: Determination of Titanium Dioxide Content - Diantipyrylmethane

Photometric Method;

---Part 7: Determination of Calcium Oxide Content Flame Atomic Absorption

Spectrophotometric Method;

---Part 8: Determination of Magnesium Oxide Content - Flame Atomic Absorption

Spectrophotometric Method;

---Part 9: Determination of Potassium Oxide and Sodium Oxide Content - Flame

Atomic Absorption Spectrophotometric Method;

---Part 10: Determination of Manganese Oxide Content - Flame Atomic Absorption

Spectrophotometric Method;

---Part 11: Determination of Chromium Oxide Content - Flame Atomic Absorption

Spectrophotometric Method;

---Part 12: Determination of Vanadium Pentoxide Content - N-Benzoy-N-

Phenylhydroxylamine Photometric Method;

---Part 13: Determination of Zinc Content - Flame Atomic Absorption

Spectrophotometric Method;

---Part 14: Determination of the Total Content of Rare Earth Oxide

Tribromoarsenazo Photometric Method;

---Part 15: Determination of Gallium Oxide Content - Rhodamine B-extraction

Photometric Method;

Methods for Chemical Analysis of Aluminum Ores -

Part 24: Determination of Carbon Content and Sulfur

Content - Infrared Absorption Method

1 Scope

This Part specifies the determination of carbon and sulfur content in aluminum ores.

This Part is applicable to the determination of carbon and sulfur content in aluminum

ores. The range of determination (mass fraction) is: for carbon, 0.02% ~ 10.00%; for

sulfur, 0.020% ~ 12.00%.

2 Method Summary

Place the sample in a high-frequency burner; under oxygen-rich conditions, heat and

burn it through a high-frequency induction furnace. The carbon and sulfur are

respectively oxidized to carbon dioxide and sulfur dioxide. Through excess oxygen,

they are loaded into the measuring cell of their respective infrared gas analyzer.

Carbon dioxide and sulfur dioxide respectively have extremely strong characteristic

absorption bands at 4.262 µm and 7.40 µm. The absorption energy is proportional to

its concentration. In accordance with the changes of energy received by the detector,

detect the carbon and sulfur content. Other gas components do not interfere with the

determination.

3 Reagents and Materials

3.1 Magnesium perchlorate: anhydrous; granular.

3.2 Alkali asbestos: granular.

3.3 Glass wool.

3.4 Tungsten particles: C <= 0.0008%, S <= 0.0005%; particle size: 0.4 mm ~ 0.8 mm.

3.5 Pure iron: purity is greater than 99.8%; carbon and sulfur contents are smaller than

0.002%; particle size: 0.8 mm ~ 1.68 mm.

3.6 Oxygen: purity is greater than 99.95%.

6.3 Calibration Test

6.3.1 In 3 ~ 5 porcelain crucibles (4.6), respectively weigh-take 0.2000 g ~ 0.4000 g of

corresponding standard samples. Cover 1.8 g of tungsten particles (3.4). Place them

on the crucible holder of a high-frequency burner; let in the oxygen stream and burn it.

Calibrate the low carbon and low sulfur channels of the instrument.

6.3.2 In 3 ~ 5 porcelain crucibles (4.6), respectively weigh-take 0.2 g of pure iron (3.5).

Weigh-take 0.1000 g of benchmark calcium carbonate (3.8); record its mass. Cover

0.2 g of pure iron (3.5) and 1.8 g of tungsten particles (3.4). Place them on the crucible

holder of a high-frequency burner; let in the oxygen stream and burn it. Calibrate the

high carbon channel of the instrument. Or, suitable standard samples with a high

carbon content may also be adopted to calibrate the high carbon channel.

6.3.3 In 3 ~ 5 porcelain crucibles (4.6), respectively weigh-take 0.2 g of pure iron (3.5).

Weigh-take 0.1000 g of potassium sulphate (3.9); record its mass. Cover 0,2 g of pure

iron (3.5) and 1.8 g of tungsten particles (3.4). Place them on the crucible holder of a

high-frequency burner; let in the oxygen stream and burn it. Calibrate the high sulfur

channel of the instrument. Or, suitable standard samples with a high sulfur content may

also be adopted to calibrate the high sulfur channel.

6.4 Times of Determination

Conduct three parallel determinations; take the average value.

6.5 Specimen

Weigh-take 0.1 g ~ 0.2 g of sample, accurate to 0.0001 g; record it as m.

6.6 Blank Test

Weigh-take 0.400 g of pure iron (3.5), place it in a crucible. Cover 1.8 g of tungsten

particles (3.4). Place on the crucible holder of a high-frequency burner; let in the

oxygen stream and burn it. Repeat enough times, till a low and relatively consistent

reading is obtained. Record at least three readings; calculate and record the average

blank value.

6.7 Sample Determination

In accordance with the requirements of the instrument, input the sample No.; place the

porcelain crucible on the balance. Add 0.20 g of pure iron (3.5); weigh-take 0.1000 g

of sample, accurate to 0.0001 g; record its mass. Cover 0.2 g of pure iron (3.5) and 1.8

g of tungsten particles (3.4). Place on the crucible holder; in accordance with the

instrument's instruction, initiate the analysis function and analyze the samples.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

How to Download YS/T 575.24-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 575.24-2009

$125.00