YS/T 575.1-2007Methods for chemical analysis of bauxite - Part 1: Determination of aluminium oxide content - EDTA titrimetric method (English PDF)
Also coversYST575.1-2007
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for YS/T 575.1-2007 in 30 minutes.
Issued by
National Development and Reform Commission
Level / Type
National · Recommended
Issue date
November 14, 2007
Implementation date
May 1, 2008
Scope
YS/T 575.1-2007 (Methods for chemical analysis of bauxite - Part 1: Determination of aluminium oxide content - EDTA titrimetric method) is available as an English-translated PDF.
YS/T 575.1-2007 — This Part specifies the determination method of aluminium oxide content in bauxite. This Part is applicable to the determination of aluminium oxide content in bauxite. The determination range is 40%~80%.
Found what you need?
Document preview — YS/T 575.1-2007
National Standard of the People's Republic of China
- ICS
- 71.100.10
- Classification
- Q 52
Issued by: National Development and Reform Commission
Contents
- Foreword...3
- 1 Scope...6
- 2 Method summary...6
- 3 Reagents...6
- 4 Specimen...8
- 5 Analysis steps...8
- 6 Expression of analysis results...9
- 7 Precision...10
- 8 Quality assurance and control...10
Foreword
YS/T 575-2007 "Methods for chemical analysis of bauxite" is a modification to
YS/T 575-2006 (formerly GB/T 3257-1999). It has 24 parts in total.
- Part 1.Determination of aluminum oxide content - EDTA titrimetric method;
- Part 2.Determination of silicon dioxide content - Gravimetric-molybdenum
blue photometric method;
- Part 3.Determination of silicon dioxide content - Molybdenum blue
photometric method;
- Part 4.Determination of iron oxide content - Potassium titrimetric method;
- Part 5.Determination of iron oxide content - Orthophenanthroline
photometric method;
- Part 6.Determination of titanium dioxide content - Diantipyrylmethane
photometric method;
- Part 7.Determination of calcium oxide content - Flame atomic absorption
spectrophotometric method;
- Part 8.Determination of magnesium oxide content - Flame atomic
absorption spectrophotometric method;
- Part 9.Determination of potassium oxide, sodium oxide content - Flame
atomic absorption spectrophotometric method;
- Part 10.Determination of manganese oxide content - Flame atomic
absorption spectrophotometric method;
- Part 11.Determination of chromium oxide content - Flame atomic
absorption spectrophotometric method;
- Part 12.Determination of vanadium pentoxide content - N-benzoyl-N-
phenylhydroxylamine photometric method;
- Part 13.Determination of zinc content - Flame atomic absorption
spectrophotometric method;
- Part 14.Determination the total content of rare earth oxide Tribromo-
arsenazo photometric method;
- Part 15.Determination of gallium oxide content - Rhodamine B-extraction
photometric method;
- Part 16.Determination of phosphorus pentoxide content - Molybdenum
blue spectrophotometric method;
- Part 17.Determination of sulfur content - Direct combustion-iodometric
method;
- Part 18.Determination of total carbon content - Non-aqueous titrimetric
method after combustion;
- Part 19.Determination of the loss on ignition - Gravimetric method;
- Part 20.Preparation of pre-dried sample;
- Part 21.Determination of organic carbon content titrimetric method;
- Part 22.Determination of hydroscopic moisture in analytical samples -
Gravimetric method;
- Part 23.Determination of element contents X-ray fluorescence
spectrometric method;
- Part 24.Determination of carbon content and sulfur content - Infrared
absorption method.
This Part is Part 1.
This Part replaces YS/T 575.1-2006 (formerly GB/T 3257.1-1999).
This Part is a modification to YS/T 575.1-2006.Compared with YS/T 575.1-
2006, the main changes in this Part are as follows.
- modified lead acetate standard solution in YS/T 575.1-2006 to zinc standard
solution, potassium fluoride solution to sodium fluoride;
- deleted the definition of "titer";
- unified the drying temperature of the specimen as 110°C±5°C;
- added precision.
This Part was proposed by and shall be under the jurisdiction of National
Technical Committee on Non-ferrous Metals of Standardization Administration
of China.
Main drafting organization of this Part. China Aluminum Corporation Zhengzhou
Research Institute.
The drafting organization of this Part. China Aluminum Corporation Shanxi
Branch.
Main drafters of this Part. Huang Anping, Yuan Xiaoke, He Xiaodong, He
Ruihong.
This Part shall be interpreted by National Technical Committee on Non-ferrous
Metals of Standardization Administration of China.
Version of standard substituted by this Part is.
- YS/T 575.1-2006 (formerly GB/T 3257.1-1999).
Methods for chemical analysis of bauxite - Part 1.
Determination of aluminium oxide content - EDTA
titrimetric method
1 Scope
This Part specifies the determination method of aluminium oxide content in
bauxite.
This Part is applicable to the determination of aluminium oxide content in
bauxite. The determination range is 40%~80%.
2 Method summary
The specimen is melted and decomposed by sodium carbonate-boric acid or
sodium hydroxide, is extracted by hot water and is acidized by hydrochloric acid.
Use lactic acid masked titanium or in the presence of EDTA, use sodium
hydroxide to separate and remove impurity elements such as iron and titanium.
Then in the weakly acidic solution, make aluminum complex with excessive
EDTA.
3 Reagents
3.1 Anhydrous sodium carbonate.
3.2 Boric acid.
3.3 Sodium hydroxide.
3.4 Sodium fluoride.
3.5 Hydrochloric acid (rho1.19g/mL).
3.6 Hydrochloric acid (1+1).
3.7 Hydrochloric acid (2+98).
3.8 Sodium hydroxide solution (400g/L).
3.9 Sodium hydroxide (100g/L).
3.18 Aluminum standard solution
3.18.1 Place metal aluminum shavings (99.99%) in a 100mL beaker. Add 25mL
of water and 25mL of hydrochloric acid (3.6). Heat to boil 5min~10min. Then
remove. After pouring the solution, use water to completely clean. Then use
absolute ethanol to wash 3 times. Place on a watch glass that is padded with
filter paper. Put into a 110°C±5°C drying oven to dry 5min. Take it out and place
in a dryer to cool.
3.19 Zinc standard solution (0.0200mol/L)
Weigh 1.3076g of high-purity zinc in a 300mL beaker. Add 50mL of water. Cover
the watch glass. Along with the beaker wall, add 15mL of nitric acid (1+1).
Slightly heat till it is completely dissolved and evaporated to 10mL~15mL. Cool
to room temperature. Use water to wash the watch glass and beaker wall. Move
into a 1000mL volumetric flask. Dilute to the scale and shake well.
4 Specimen
Use a mortar to grind the specimen. Through a 74µm sieve, place the well-
ground specimen at 110°C±5°C to dry 2h. Place in a dryer. Cool to room
temperature for use.
5 Analysis steps
5.1 Test portion
Weigh 0.25g of specimen (4), to the nearest of 0.0001g.
5.2 Determination times
It shall conduct two determinations independently to a same specimen. Take
the average value.
5.3 Determination
5.3.1 Test portion decomposition by any of the following methods
5.3.3 Titration
Add 20mL of acetic acid-sodium acetate buffer (3.14) to the solution that is
separated after 5.3.2.1 or 5.3.2.2.Heat and boil 2min~3min. Remove it. Cool it
under tap water to room temperature. Add 2 drops of xylenol orange indicator
solution (3.17).
6 Expression of analysis results
Calculate the mass fraction (%) of aluminum oxide according to the formula as
below.
7 Precision
7.1 Repeatability
Measured values of two independent test results are obtained under repeatable
conditions.
7.2 Tolerance
The difference between laboratory analysis results shall not be greater than the
tolerances listed in Table 1.
8 Quality assurance and control
In analysis, use standard sample or control sample to verify. Or, at least use
standard sample or control sample to verify the analysis method once a year.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
How to Download YS/T 575.1-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 575.16-2007 — Methods for chemical analysis of bauxite. Part 16: Determination of phosphorus pentoxide content. Molybdenum blue spectrophotometric method
YS/T 575.17-2007 — Methods for chemical analysis of bauxite. Part 17: Determination of sulfur content. Direct combustion-iodometric method
YS/T 575.19-2021 — Methods for chemical analysis of bauxite - Part 19: Determination of loss on ignition - Gravimetric method
Secure payment via Stripe
Payments accepted
YS/T 575.1-2007
$65.00