Valid

YS/T 555.7-2009Methods for chemical analysis of molybdenum concentrate. Determination of calcium oxide content. Flame atomic absorption spectrometry (English PDF)

钼精矿化学分析方法氧化钙量的测定火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (4 pages)

Need quotation for your management?

Get a formal quotation for YS/T 555.7-2009 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

December 4, 2009

Implementation date

June 1, 2010

Scope

YS/T 555.7-2009 is the English-translated version of 钼精矿化学分析方法氧化钙量的测定火焰原子吸收光谱法.

YS/T 555.7-2009 — This section provides the determination of calcium oxide content of molybdenum concentrate. This section applies to the determination of calcium oxide content of molybdenum concentrate. Measuring range. 0.08% - 4.80%.

Found what you need?

Document preview — YS/T 555.7-2009

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 14;D43
Replacing
YS/T 555.7-2006

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument
  • 5 Sample

Foreword

YS/T 555 "Methods for chemical analysis of molybdenum concentrate" includes 11 parts.

YS/T 555.1 Methods for chemical analysis of molybdenum concentrate molybdenum content of lead molybdate assay gravimetric method YS/T 555.2 Methods for chemical analysis of molybdenum concentrate - Determination of silicon dioxide content and weight of molybdenum blue spectrophotometric method YS/T 555.3 Methods for chemical analysis of molybdenum concentrate arsenic content - Atomic Fluorescence Spectrometry and DDTC-Ag spectrophotometry YS/T 555.4 Methods for chemical analysis of molybdenum concentrate tin content - Atomic Fluorescence Spectrometry YS/T 555.5 Methods for chemical analysis of molybdenum concentrate phosphorus content of molybdenum blue spectrophotometric determination of phosphorus YS/T 555.6 Methods for chemical analysis of molybdenum concentrate copper, lead, bismuth, zinc content - Flame Atomic Absorption Spectrometry YS/T 555.7 Methods for chemical analysis of molybdenum concentrate calcium oxide content by flame atomic absorption spectrometry YS/T 555.8 Methods for chemical analysis of molybdenum concentrate - Determination of tungsten content - Thiocyanate spectrophotometric method YS/T 555.9 Methods for chemical analysis of molybdenum concentrate the amount of potassium and sodium contents - Flame Atomic Absorption Spectrometry YS/T 555.10 Methods for chemical analysis of molybdenum concentrate rhenium contents - Thiocyanate spectrophotometric Determination of YS/T 555.11 Methods for chemical analysis of molybdenum concentrate oil and moisture content of the total weight of the law this is Part 7.

"The method concentrates - Determination of calcium content" in this section instead of YS/T 555.7-2006 (formerly GB/T 15079.7-1994).

This portion of YS/T 555.7-2006 compared to the main changes are as follows.

Determination of calcium --- revision for the determination of calcium oxide content;

--- Increasing the molybdenum substrate method to eliminate interference;

--- Increasing the precision of the terms;

--- Text format has been modified, supplemented with quality assurance and control provisions.

The non-ferrous metal part by the National Standardization Technical Committee and centralized.

This section is responsible for drafting unit. Jinduicheng Molybdenum Group Co., Ltd., China Nonferrous Metals Industry Institute of Standards and Metrology and Quality.

Participated in the drafting of this section. Luoyang Luanchuan Molybdenum Group Co., Jiangxi Copper Company (Dexing) mine development of new technologies limited the company.

1 Scope

This section provides the determination of calcium oxide content of molybdenum concentrate.

This section applies to the determination of calcium oxide content of molybdenum concentrate. Measuring range. 0.08% - 4.80%.

2 Method summary

Sample prior to 500 °C muffle furnace burning to remove large amounts of sulfur, carbon, oil, and then acid decomposition. Hydrochloric acid in a suitable medium, strontium salt and lanthanum salts as release agents, atomic absorption spectrometer at a wavelength of 422.7nm, air - acetylene flame measured absorbance of calcium oxide.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity.

3.1 nitrate (rho1.42g/mL), pure class distinctions.

3.2 hydrochloric acid (rho1.19g/mL), pure class distinctions.

3.3 Hydrofluoric acid (rho1.13g/mL).

3.4 perchloric acid (rho1.68g/mL), pure class distinctions.

3.5 HCl (1 + 1).

3.6 strontium chloride and lanthanum chloride mixed solution. Weigh 10g pure spectrum of strontium chloride (SrCl2 · 6H2O) and lanthanum chloride 20g pure spectrum, placed 400mL beaker, add a small amount of water, dissolved by heating, cooling, transferred to 200mL volumetric flask, dilute with water to volume, and mix.

3.7 calcium oxide standard solution. Weigh 0.1785g advance at 105 °C drying 1h and was cooled to room temperature inside the dryer calcium carbonate (base Quasi reagent), placed in 300mL beaker, covered with a watch glass, was added 10mL of hydrochloric acid (3.5) low-temperature heating to dissolve completely cooled and transferred to 1000mL Volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 100µg calcium oxide. Store in plastic bottle.

3.8 molybdenum substrate solution (5mg/mL). Weigh 0.7500g of high purity molybdenum trioxide reagent in 200mL beaker, add 30mL water and 1mL ammonia (rho0.90g/mL, superior grade pure), after dissolved by heating, boiling 5min, cooled and transferred to 100mL volumetric flask, dilute to the mark with water Degree, and mix.

4 Instrument

Atomic absorption spectrometer, with a calcium hollow cathode lamp.

Under optimum working conditions for those who can reach the following indicators can be used.

--- Precision minimum requirements. measuring the absorbance of the highest standard solution 10 times the standard deviation should not exceed the average absorbance 1.0%. Lowest measured standard solution (not a "zero" standard solution) absorbance of 10 times the standard deviation should not exceed the maximum standard 0.5% average standard solution absorbance.

--- Characteristic concentration. the test solution and measurement matrix consistent solution, characterized in calcium concentration should not exceed 0.08µg/mL.

--- Linear standard curve. The standard curve is divided into five sections according to concentration, than the difference between the absorbance of the absorbance difference between the highest and the lowest segment not less than 0.7.

5 Sample

Specimens shall be pre-stripped oil and moisture, particle size less than 0.090mm. After the sample should be 100 °C ~ 105 °C baking 1h, dry place

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

How to Download YS/T 555.7-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 555.7-2009

$125.00