Valid

YS/T 555.10-2009Methods for chemical analysis of molybdenum concentrate. Determination of rhenium content. Thiocyanate spectrophotometry (English PDF)

钼精矿化学分析方法铼量的测定硫氰酸盐分光光度法

Preview PDF

This is a limited preview

Buy now to download the full PDF (4 pages)

Need quotation for your management?

Get a formal quotation for YS/T 555.10-2009 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

December 4, 2009

Implementation date

June 1, 2010

Scope

YS/T 555.10-2009 is the English-translated version of 钼精矿化学分析方法铼量的测定硫氰酸盐分光光度法.

YS/T 555.10-2009 — This section provides the determination of rhenium content of molybdenum concentrate. This section applies to the determination of the rhenium content of molybdenum concentrate. Measurement range. 0.0010% to 0.20%.

Found what you need?

Document preview — YS/T 555.10-2009

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 14
Replacing
YS/T 555.11-2006

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument

Foreword

YS/T 555 "Methods for chemical analysis of molybdenum concentrate" includes 11 parts.

YS/T 555.1 Methods for chemical analysis of molybdenum concentrate molybdenum content of lead molybdate assay gravimetric method YS/T 555.2 Methods for chemical analysis of molybdenum concentrate - Determination of silicon dioxide content and weight of molybdenum blue spectrophotometric method YS/T 555.3 Methods for chemical analysis of molybdenum concentrate arsenic content - Atomic Fluorescence Spectrometry and DDTC-Ag spectrophotometry YS/T 555.4 Methods for chemical analysis of molybdenum concentrate tin content - Atomic Fluorescence Spectrometry YS/T 555.5 Methods for chemical analysis of molybdenum concentrate phosphorus content of molybdenum blue spectrophotometric determination of phosphorus YS/T 555.6 Methods for chemical analysis of molybdenum concentrate copper, lead, bismuth, zinc content - Flame Atomic Absorption Spectrometry YS/T 555.7 Methods for chemical analysis of molybdenum concentrate calcium oxide content by flame atomic absorption spectrometry YS/T 555.8 Methods for chemical analysis of molybdenum concentrate - Determination of tungsten content - Thiocyanate spectrophotometric method YS/T 555.9 Methods for chemical analysis of molybdenum concentrate the amount of potassium and sodium contents - Flame Atomic Absorption Spectrometry YS/T 555.10 Methods for chemical analysis of molybdenum concentrate rhenium contents - Thiocyanate spectrophotometric Determination of YS/T 555.11 Methods for chemical analysis of molybdenum concentrate oil and moisture content of the total weight of the law this section 10.

"Concentrates - Methods of measuring the amount of rhenium" in this section instead of YS/T 555.11-2006 (formerly GB/T 15079.11-1994).

This portion of YS/T 555.11-2006 compared to the main changes are as follows.

--- Increasing the precision of the terms;

--- Text format has been modified, supplemented with quality assurance and control provisions.

The non-ferrous metal part by the National Standardization Technical Committee and centralized.

This section is responsible for drafting unit. Jinduicheng Molybdenum Group Co., Ltd., China Nonferrous Metals Industry Institute of Standards and Metrology and Quality.

Participated in the drafting of this section. JCC (Dexing) New Mining Technology Development Company Limited.

1 Scope

This section provides the determination of rhenium content of molybdenum concentrate.

This section applies to the determination of the rhenium content of molybdenum concentrate. Measurement range. 0.0010% to 0.20%.

2 Method summary

Samples to fusion with sodium peroxide, flooding out. In pH12 ~ pH13 solution, rhenium and the four phenylarsonic chloride hydrochloride formed over rhenium acid tetraphenyl Arsine, extracted with chloroform, and molybdenum separation. With 6mol/L hydrochloric acid, and extracted tin dichloride reduction, color thiocyanate, extracted with ethyl acetate Take, on a spectrophotometer at a wavelength of 430nm measured absorbance.

3 Reagents

3.1 sodium peroxide.

3.2 tartaric acid.

3.3 chloroform.

3.4 ethyl acetate.

3.5 hydrochloride (rho1.19g/mL).

3.6 sulfuric acid solution (1 + 1).

3.7 hydrochloric acid solution (1 + 1).

3.8 Sodium hydroxide solution (400g/L).

3.9 solution of potassium thiocyanate (350g/L).

3.10 stannous chloride solution (200g/L). Weigh 200g of tin dichloride in 1000mL beaker, was added a solution of hydrochloric acid (3.7) were dissolved and Volume to 1000mL, the time is now equipped with.

3.11 disodium ethylenediamine tetraacetate (EDTA) solution (100g/L).

3.12 four phenylarsonic chloride hydrochloride solution (10g/L).

3.13 tetracene arsine chloride hydrochloride bath. in 1000mL of water were added 10mL tetracene arsine chloride hydrochloride solution (3.12), 8mL hydroxide Sodium solution (100g/L), and mix.

3.14 ethanol solution (98 + 2).

3.15 rhenium standard stock solution. Weigh 0.1000g powder metal rhenium (Re mass fraction greater than or equal to 99.99%) in the 150mL beaker, Hydrochloric acid solution was added 20mL (1 + 1), 5mL solution of nitric acid (1 + 1), heated until completely dissolved, cooled to room temperature, transferred to 1000mL container Volumetric flask, dilute to the mark and mix. This solution 1mL containing 100µg rhenium.

3.16 Rhenium standard solution. Pipette 20.00mL rhenium standard stock solution (3.15) in 500mL volumetric flask, dilute to the mark, mix uniform. 1mL solution containing 4µg rhenium.

3.17 resorcinol products yellow indicator (1g/L).

4 Instrument

Spectrophotometer.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

How to Download YS/T 555.10-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 555.10-2009

$125.00