Valid

YS/T 514.6-2009Methods for chemical analysis of high-titanium slag and rutile. Part 6: Determination of manganese monoxide content. Flame atomic absorption spectrometry (English PDF)

高钛渣、金红石化学分析方法 第6部分:一氧化锰量的测定 火焰原子吸收光谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (4 pages)

Need quotation for your management?

Get a formal quotation for YS/T 514.6-2009 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

December 4, 2009

Implementation date

June 1, 2010

Scope

YS/T 514.6-2009 is the English-translated version of 高钛渣、金红石化学分析方法 第6部分:一氧化锰量的测定 火焰原子吸收光谱法.

YS/T 514.6-2009 — YS/T 514 This part provides high titanium slag and rutile in a determination of manganese oxide content. This section applies to high titanium slag and rutile in a determination of manganese oxide content. Measurement range. 0.10 to 5.00%.

Found what you need?

Document preview — YS/T 514.6-2009

National Standard of the People's Republic of China

ICS
77.120.90
Classification
H 14;D42
Replacing
YS/T 514.9-2006

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument
  • 5 Sample
  • 6 Step, Analysis
  • 6.1 Sample

Foreword

YS/T 514 "high titanium slag and rutile chemical analysis method" is divided into 10 parts.

--- Part 1. Determination of titanium dioxide content of ammonium ferric sulfate titration;

--- Part 2. Determination of total iron content of dichromate method;

--- Part 3. Determination of sulfur content of high frequency infrared absorption method;

--- Part 4. Determination of the amount of silica weighing method, the molybdenum blue spectrophotometric method;

--- Part 5. aluminum oxide content - EDTA titration;

--- Part 6. Determination of a manganese oxide content by flame atomic absorption spectrometry;

--- Part 7. calcium oxide, magnesium oxide content - Flame atomic absorption spectrometry;

--- Part 8. Determination of the amount of phosphorus antimony molybdenum blue spectrophotometric method;

--- Part 9. calcium oxide, magnesium oxide, manganese oxide, phosphorus, chromium oxide and vanadium pentoxide content - Inductively coupled plasma Daughters emission spectrometry;

--- Part 10. Determination of the amount of carbon frequency infrared absorption method.

This section YS/T 514 Part 6.

The partial replacement of YS/T 514.9-2006 "high titanium slag and rutile measured chemical analysis of a manganese oxide content of a persulfate Arsenite volumetric method. " this portion of YS/T 514.9-2006 compared to the main changes are as follows.

--- Manganese oxide content was determined by a flame atomic absorption spectrometry;

--- Increasing the precision and quality assurance provisions.

The non-ferrous metal part by the National Standardization Technical Committee and centralized.

This section is responsible for drafting unit. Zunyi Titanium Co., Ltd., China Nonferrous Metals Industry Standards and Metrology Institute for Quality.

Participated in the drafting of this section. Jinchuan Group Co., Ltd. Fushun Titanium.

1 Scope

YS/T 514 This part provides high titanium slag and rutile in a determination of manganese oxide content.

This section applies to high titanium slag and rutile in a determination of manganese oxide content. Measurement range. 0.10 to 5.00%.

2 Method summary

Sample to fusion with sodium peroxide with dilute hydrochloric acid leaching. Atomic absorption spectrophotometer, at a wavelength of 279.5nm, air - acetylene Determination of manganese flame absorbance, thereby calculating the amount of a sample of manganese oxide.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical reagent or distilled or deionized water or equivalent purity.

3.1 sodium peroxide.

3.2 HCl (1 + 1).

3.3 sulfate (1 + 4).

3.4 manganese standard stock solution. Weigh 0.1000g pure manganese (Mn mass fraction >=99.99%), with 20mL of sulfuric acid (3.3) dissolved shift Into 1000mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 0.1mg of manganese.

3.5 Manganese standard solution. Pipette 10.00mL manganese standard stock solution (3.4) into 100mL volumetric flask, dilute to the mark with water, mix uniform. This solution 1mL manganese 10µg.

4 Instrument

Atomic absorption spectrometer, with a manganese hollow cathode lamp.

Under optimum working conditions for those who can reach the following indicators can be used.

--- Characteristic concentration. a solution in the matrix is consistent with the measured solution, the concentration of Mn characteristic should not exceed 0.03µg/mL.

--- Precision. measuring the absorbance of 10 with the highest concentration of standard solution, the standard deviation should not exceed the average absorbance of 1.0%, with the lowest concentration of standard solution (not "zero" concentration of the standard) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum concentration 0.5% of the mean absorbance of the standard solution.

--- Linear curve. The curve is divided into five sections according to concentration, absorbance difference absorbance difference between the highest and the lowest segment of the segment Ratio of not less than 0.7.

5 Sample

5.1 Sample size should be less than 90µm.

5.2 Sample required in advance at 105 °C ~ 110 °C drying 2h, placed in a desiccator to cool to room temperature.

6 Step, Analysis

6.1 Sample

Weigh 0.1g sample, accurate to 0.0001g.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.

How to Download YS/T 514.6-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
4 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 514.6-2009