Valid

YS/T 514.10-2009Methods for chemical analysis of high titanium slag and rutile. Part 10: Determination of carbon content. High frequency infrared absorption method (English PDF)

高钛渣、金红石化学分析方法 第10部分:碳量的测定 高频红外吸收法(有黑印,不清晰)

Preview PDF

This is a limited preview

Buy now to download the full PDF (3 pages)

Need quotation for your management?

Get a formal quotation for YS/T 514.10-2009 in 30 minutes.

Issued by

Ministry of Industry and Information Technology

Level / Type

National · Recommended

Issue date

December 4, 2009

Implementation date

June 1, 2010

Scope

YS/T 514.10-2009 is the English-translated version of 高钛渣、金红石化学分析方法 第10部分:碳量的测定 高频红外吸收法(有黑印,不清晰).

YS/T 514.10-2009 — YS/T 514 This part provides high titanium slag and rutile measured carbon content. This section applies to high titanium slag and rutile measured carbon content. Measurement range. 0.0010% to 3.50%.

Found what you need?

Document preview — YS/T 514.10-2009

National Standard of the People's Republic of China

ICS
77.120.90
Classification
H 14;D42
Replacing
YS/T 514.4-2006

Issued by: Ministry of Industry and Information Technology

Contents

  • Foreword
  • 1 Scope
  • 2 Principle of the method
  • 3 Reagents and materials
  • 3.1 Tungsten particles. particle size of 0.4mm ~ 0.8mm, carbon content 4 Instrument
  • 5 Sample
  • 6 Step, Analysis
  • 7 Precision
  • 7.1 Repeatability

Foreword

YS/T 514 "high titanium slag and rutile chemical analysis method" is divided into 10 parts.

--- Part 1. Determination of titanium dioxide content of ammonium ferric sulfate titration;

--- Part 2. Determination of total iron content of dichromate method;

--- Part 3. Determination of sulfur content of high frequency infrared absorption method;

--- Part 4. Determination of the amount of silica weighing method, the molybdenum blue spectrophotometric method;

--- Part 5. aluminum oxide content - EDTA titration;

--- Part 6. Determination of a manganese oxide content by flame atomic absorption spectrometry;

--- Part 7. calcium oxide, magnesium oxide content - Flame atomic absorption spectrometry;

--- Part 8. Determination of the amount of phosphorus antimony molybdenum blue spectrophotometric method;

--- Part 9. calcium oxide, magnesium oxide, manganese oxide, phosphorus, chromium oxide and vanadium pentoxide content - Inductively coupled plasma Daughters emission spectrometry;

--- Part 10. Determination of the amount of carbon frequency infrared absorption method.

This section YS/T 514 Part 10.

The partial replacement of YS/T 514.4-2006 "high titanium slag and rutile chemical analysis of combustion - coulometric method for the determination of carbon content." this portion of YS/T 514.4-2006 compared to the main changes are as follows.

--- Changed the measurement method by combustion - coulometric method for modifying the high frequency infrared absorption method;

--- Measured by the scope of 0.010% ~ 0.500% revised to 0.0010% to 3.50%.

--- Increasing the repeatability limit and quality assurance and control provisions.

The non-ferrous metal part by the National Standardization Technical Committee and centralized.

This section is responsible for drafting unit. Zunyi Titanium Co., Ltd., China Nonferrous Metals Industry Standards and Metrology Institute for Quality.

Participated in the drafting of this section. Jinchuan Group Co., Ltd. Fushun Titanium.

1 Scope

YS/T 514 This part provides high titanium slag and rutile measured carbon content.

This section applies to high titanium slag and rutile measured carbon content. Measurement range. 0.0010% to 3.50%.

2 Principle of the method

Sample in the presence of a suitable amount of flux, which leads to oxygen in a high frequency induction furnace combustion. Carbon in a sample of a gas (CO and CO2) released in the form, and with the oxygen carrier gas through the catalyst is oxidized to CO2. When air flows through the CO2 infrared detection pool pool, pool detected by measuring the amount of energy change detector to a concentration of CO2.

3 Reagents and materials

3.1 Tungsten particles. particle size of 0.4mm ~ 0.8mm, carbon content 4 Instrument

High-frequency infrared carbon and sulfur analyzer.

5 Sample

5.1 Sample size should be less than 90µm.

5.2 Sample required at 105 °C ~ 110 °C drying 2h, placed in a desiccator to cool to room temperature.

5.3 the sample should have oil, grease and other contaminants.

6 Step, Analysis

6.1 Switch on the instrument, preheat 10min after viewing the relevant instrument parameters, confirm the determination to meet the requirements of the instrument.

6.2 Weigh 1.5g of tungsten particles (3.1), placed in a crucible (3.6), the determination is repeated more than four times, setting a blank after completion.

6.3 0.1g weighed (accurate to 0.001 g of) standard samples (3.7), placed in a crucible (3.6) was added 1.5g tungsten particles (3.1) uniformly covered in the standard surface, were measured. More than four times repeated measurements, carried out after the standard setting.

6.4 0.1g weighed (accurate to 0.001 g of) sample (5) placed in a crucible (3.6) was added 1.5g tungsten particles (3.1) evenly covering the sample the surface was measured. Repeat 2 more times measured and averaged.

7 Precision

7.1 Repeatability

Found two independent test results obtained under repeatability conditions within the average range given below, these two test results

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 3 pages — is available in the English PDF.

How to Download YS/T 514.10-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
3 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YS/T 514.10-2009

$85.00