YS/T 281.2-2011Methods for chemical analysis of cobalt. Part 2: Determination of aluminum content. Chromeazurol S spectrophotometry (English PDF)
钴化学分析方法 第2部分:铝量的测定铬天青S分光光度法
This is a limited preview
Buy now to download the full PDF (5 pages)
Need quotation for your management?
Get a formal quotation for YS/T 281.2-2011 in 30 minutes.
Issued by
Ministry of Industry and Information Technology
Level / Type
National · Recommended
Issue date
December 20, 2011
Implementation date
July 1, 2012
Scope
YS/T 281.2-2011 is the English-translated version of 钴化学分析方法 第2部分:铝量的测定铬天青S分光光度法.
YS/T 281.2-2011 — This section YS/T 281 provides for determination of cobalt in aluminum content. This section applies to the determination of cobalt in aluminum content. Measurement range. 0.00030% to 0.0050%.
Found what you need?
Document preview — YS/T 281.2-2011
National Standard of the People's Republic of China
- ICS
- 77.120.70
- Classification
- H 13
- Replacing
- YS/T 281.2-1994
Issued by: Ministry of Industry and Information Technology
Contents
- Foreword
- 1 Scope
- 2 Method summary
- 3 Reagents
Foreword
YS/T 281 "cobalt chemical analysis method" is divided into the following 20 sections.
--- Part 1. Determination of iron content sulfonic acid spectrophotometry
--- Part 2. Determination of the amount of chrome aluminum Azure S Spectrophotometry
--- Part 3. Determination of silicon content - Molybdenum blue spectrophotometric method
--- Part 4. Determination of arsenic content - Molybdenum blue spectrophotometric method
--- Part 5. Determination of phosphorus content - Molybdenum blue spectrophotometric method
--- Part 6. Determination of magnesium content - Flame atomic absorption spectrometry
--- Part 7. Determination of zinc content - Flame atomic absorption spectrometry
--- Part 8. Determination of cadmium content by flame atomic absorption spectrometry
--- Part 9. Determination of lead content - flame atomic absorption spectrometry
--- Part 10. Determination of nickel content by flame atomic absorption spectrometry
--- Part 11. Flame atomic copper, manganese content absorption spectrometry
--- Part 12. arsenic, antimony, bismuth, tin, lead and determining the amount of electrothermal atomic absorption spectrometry
--- Part 13. Determination of sulfur content high frequency induction furnace combustion infrared absorption method
--- Part 14. Determination of the amount of carbon high-frequency induction furnace combustion infrared absorption method
--- Part 15. arsenic, antimony, bismuth contents - Hydride Generation - Atomic Fluorescence Spectrometry
--- Part 16. Determination of DC arc atomic arsenic, cadmium, copper, zinc, lead, bismuth, tin, antimony, silicon, manganese, iron, nickel, aluminum, magnesium content of the emitted light Spectroscopy
--- Part 17. aluminum, manganese, nickel, copper, zinc, cadmium, tin, antimony, lead, bismuth content - Inductively Coupled Plasma Mass Spectrometry
--- Part 18. Determination of sodium content by flame atomic absorption spectrometry
--- Part 19. calcium, magnesium, manganese, iron, cadmium, zinc content - Inductively coupled plasma atomic emission spectrometry
--- Part 20. Determination of oxygen content - Impulse - infrared absorption method this section YS/T 281 Part 2.
This section drafted in accordance with GB/T 1.1-2009 given rules.
The partial replacement of YS/T 281.2-1994 "Methods for chemical analysis of cobalt chrome azure S spectrophotometric determination of aluminum content." versus YS/T 281.2-1994 compared, this section there are major changes as follows.
--- Measured by the scope of 0.0003% ~ 0.002% revised to 0.00030% to 0.0050%;
--- Text format has been modified, supplemented with quality assurance and control provisions, increase the repeatability limit and reproducibility limit;
--- Complement the test reporting requirements.
The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) and focal points.
1 Scope
This section YS/T 281 provides for determination of cobalt in aluminum content.
This section applies to the determination of cobalt in aluminum content. Measurement range. 0.00030% to 0.0050%.
2 Method summary
Sample was dissolved in nitric acid at pH4.6 ~ 5.2, the use of ethyl benzoate and aluminum benzoate cobalt extraction separation. With hydrochloric acid trans the organic phase was extracted aluminum. Aluminum and CAS S- bromo emulsifier OP- cylpyridinium form a complex at 610nm wavelength spectrophotometer Measured absorbance.
3 Reagents
Unless otherwise specified, the reagents were analytical reagent solution preparation and analysis are secondary distilled water or equivalent purity test Room with water.
3.1 hydrochloric acid (rho = 1.19g/mL) of high purity.
3.2 nitric acid (rho = 1.42g/mL) of high purity.
3.3 ammonium hydroxide (rho = 0.90g/mL) of high purity.
3.4 hydrochloride (11).
3.5 hydrochloric acid (119).
3.6 ammonium hydroxide solution (120), stored in a plastic bottle.
3.7 nitric acid (32).
3.8 Chromium Azure S solution (1g/L). Weigh 0.20g Chromium Azure S dissolved in 100mL of water, diluted to 200mL with ethanol.
3.9 polyethylene glycol octylphenyl ether (emulsifier OP) solution (1999).
Bromo cylpyridinium 3.10 (TPB) solution (4g/L).
3.11 acetic acid - ammonium acetate buffer solution. A 485mL solution of ammonium acetate (4mol/L) was diluted to 500mL with acetic acid (4mol/L), Mix well.
3.12 ammonium benzoate solution (120g/L). Weigh 12g of ammonium benzoate was dissolved in water, adding 2 to 3 drops of ammonium hydroxide (3.3) dissolved End Full, dilute with water to 100mL.
3.13 Ammonium benzoate lotion (20g/L). Weigh 2g ammonium benzoate was dissolved in 100mL of water, carefully adjust the pH with dilute hydrochloric acid on pH meter is between 4.6 to 4.8.
3.14 benzoic acid - ethyl acetate solution (50g/L). Weigh 25g of benzoic acid dissolved in ethyl acetate, diluted to 500mL with ethyl acetate.
3.15 hydroxylamine hydrochloride solution (100g/L). the time is now equipped with.
3.16 ascorbic acid solution (10g/L). the time is now equipped with.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
How to Download YS/T 281.2-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
YS/T 281.1-2011 — Methods for chemical analysis of cobalt. Part 1: Determination of iron content. Sulfosalicylic acid spectrophotometry
YS/T 281.10-2011 — Methods for chemical analysis of cobalt. Part 10: Determination of nickel content. Flame atomic absorption spectrometry
YS/T 281.11-2011 — Methods for chemical analysis of cobalt. Part 11: Determination of copper and manganese contents. Flame atomic absorption spectrometry
Secure payment via Stripe
Payments accepted
YS/T 281.2-2011
$105.00